Small Buildings study guideHouses and Part 9

Special buildings and structures (Part 3)

Self-service storage, public pools, public spas, tents and air-supported structures, signs, and shelf and rack storage.

chapters in this guide
7 of 15
chapters in this guide
to read
5 min
to read
code articles cited
28
code articles cited

Last updated

Values this chapter turns on

dwelling units served makes a Class B pool
6 or more
dwelling units served makes a Class B pool
daily turnover of pool volume, Class B
4 times
daily turnover of pool volume, Class B
small tent limit, no bleachers or sidewalls
225 m²
small tent limit, no bleachers or sidewalls
minimum clearance under a sign over a sidewalk
2,400 mm
minimum clearance under a sign over a sidewalk

Part 3 has a group of sections for buildings and structures that do not fit the normal rules: self-service storage buildings (3.10.), public pools (3.11.), public spas (3.12.), tents and air-supported structures (3.14.), signs (3.15.) and shelf and rack storage systems (3.16.). The Small Buildings syllabus lists all six. Each one starts by saying which normal Part 3 rules apply and then changes a few of them. Most exam questions are lookups of one number or one exception, so learn where each section starts.

Self-service storage buildings

A self-service storage building is one that gives individual storage spaces to the public and is open to the public only for that purpose (OBC Div. A 1.4.1.2.OBC Div. A 1.4.1.2.(1) Self-service storage buildingSelf-service storage building means a building that is used to provide individual storage spaces to the public and that is open to the public only for those purposes.). It must meet the rules for a Group F, Division 2 major occupancy and must not contain any Group F, Division 1 occupancy (OBC Div. B 3.10.2.1.OBC Div. B 3.10.2.1. Occupancy Classification(1) A self-service storage building (a) shall comply with the requirements for a Group F, Division 2 major occupancy, and (b) shall not contain a Group F, Division 1 occupancy.). Requirements based on occupant load do not apply (3.10.2.2.OBC Div. B 3.10.2.2. Occupant Load(1) The requirements based on occupant load shall not apply.).

Key changes to the normal rules:

Topic Self-storage rule Article
First storey compartments max 500 m², 1 h masonry or concrete fire separation, or sprinklered 3.10.2.3.(2)
Corridor not built as a public corridor travel distance from inside rental space to exit not more than 15 m 3.10.2.4.(2)
Doors need not swing with exit travel rental space not more than 50 m² and travel within it not more than 10 m 3.10.2.4.(4)
Corridor width, doors swing into it at least 1,500 mm, doors not more than 914 mm 3.10.2.4.(5)
Dwelling units not more than 2 on the property, 2 h separation 3.10.2.4.(9), (10)
Exit stair clear width at least 1,100 mm 3.10.2.5.(2)

Dead-end corridors are not allowed at all. Buildings other than one storey with no basement or mezzanine must have a fire alarm system and be at least 9 m apart (3.10.3.2.OBC Div. B 3.10.3.2. Spatial Separations(1) Except as provided in Sentence (2), the requirements in Subsection 3.2.3. shall apply. (2) The distance between buildings shall be not less than 9 m., 3.10.3.3.OBC Div. B 3.10.3.3. Fire Alarm Systems(1) Except as provided in Sentences (2) and (3), the requirements in Subsection 3.2.4. shall apply. (2) A fire alarm system shall be installed. (3) Within the first storey, manual stations are required only in corridors.). For one-storey buildings with no basement or mezzanine, building area may be taken building by building or as a group, and buildings within a group must be at least 6 m apart (3.10.4.3.OBC Div. B 3.10.4.3. Spatial Separations(1) Except as provided in Sentences (2) to (4), the requirements in Subsection 3.2.3. shall apply. (2) Where the building area conforms to Clause 3.10.4.2.(1)(b), the limiting distance requirements shall not apply between individual buildings. (3) Where the building area conforms to Clause 3.10.4.2.(1)(c), (a) the…). Fire access routes are at least 9 m wide in both cases.

Practice this topic

Public pools and public spas

A public pool excludes, among others, pools serving fewer than six dwelling units, wading pools, hydro-massage pools and water slide receiving basins (OBC Div. A 1.4.1.2.OBC Div. A 1.4.1.2. Defined Terms(1) The words and terms in italics in this Code shall have the following meanings: (a) the same meaning as in subsection 1(1) of the Act, if not defined in Clause (b) or (c), (b) the same meaning as in each of the following provisions for the purposes described in the provision: (i) Sentences 1.4.1.3.(1) and (2) of…). Every public pool is either Class A or Class B (OBC Div. B 3.11.2.1.OBC Div. B 3.11.2.1. Pool Designations(1) Every public pool shall be designated as being either a Class A pool or a Class B pool in accordance with Sentence (2) or (3). (2) A Class A pool is a public pool to which the general public is admitted or that is (a) operated in conjunction with or as a part of a program of an educational, instructional, physical…):

  • Class A: the general public is admitted, or it is run by a publicly funded educational, fitness or athletic body, or it is at a recreational camp.
  • Class B: it serves six or more dwelling units or suites, a mobile home park, a hotel, a campground, a club, or a Group B institution, for residents and their visitors.

Construction numbers in 3.11.3.1.OBC Div. B 3.11.3.1. Construction Requirements(1) Except as otherwise required in Subsections 3.11.4., 3.11.5., 3.11.6. and 3.11.7. or otherwise exempted in Sentences (2) and (3), Class A pools and Class B pools shall be designed and constructed to comply with Sentences (2) to (28) and Articles 3.11.3.2. and 3.11.3.3. (2) Where a Class B pool is constructed for… that come up often: minimum water depth 750 mm (with exceptions), maximum bottom slope 8% where the water is 1,350 mm deep or less, pool deck at least 1,800 mm wide with 1,100 mm of it barrier-free, outdoor deck slope 2% to 4%, indoor deck slope 1% to 4%, and a 150 mm black disc at the deepest point. Diving board water depths are in 3.11.4.1.OBC Div. B 3.11.4.1. Diving Boards or Platforms(1) No diving board or diving platform shall be installed in a public pool unless the requirements of Sentences (5) to (17) are met but the requirements for a diving platform do not apply to a starting platform. (2) No diving board or diving platform shall be installed in a modified pool or a wave action pool. (3)…: 2,750 mm under a board 600 mm or less above the water, 3 m for boards over 600 mm up to 1,000 mm, and 3.65 m for boards over 1,000 mm up to 3 m.

Recirculation turnover per day is set by class (3.11.8.1.OBC Div. B 3.11.8.1. Recirculation Systems(1) Every public pool shall be equipped with a recirculation system. (2) For the purposes of this Subsection, the water in a public pool and its recirculation system is deemed not to be potable water. (3) The water in a public pool and its recirculation system shall be separated from the potable water supply and from…): six times the pool volume for Class A, four times for Class B, three times for a modified pool. Pool water is deemed not potable and must be separated from the potable supply. Sanitary facilities use one shower head per 40 bathers and showers tempered to not more than 40°C (3.11.9.1.OBC Div. B 3.11.9.1. Dressing Rooms and Sanitary Facilities(1) Except as otherwise permitted in Sentences (2) and (3), every public pool shall be equipped with dressing rooms, locker rooms, shower heads, water closets, urinals, lavatories and drinking fountains that shall be designed, constructed and equipped to comply with Sentences (4) to (14). (2) Where a Class A pool is…).

Public spas follow 3.12. A spa may be no deeper than 1,200 mm, with a bottom slope of not more than 8% and not more than 600 mm of water over a seat (OBC Div. B 3.12.2.1.OBC Div. B 3.12.2.1. Construction Requirements(1) In addition to the requirements of this Subsection, public spas shall comply with the requirements of Sentences 3.11.3.1.(13) to (18), (20), (21) and (23) and Clause 3.11.3.1.(25)(a). (2) A public spa shall be constructed to have a water depth of not more than 1,200 mm. (3) The slope of the bottom of any portion…). Turnover is 30, 20 or 15 minutes depending on volume, and the heater cut-off limits water to 40°C (3.12.4.1.OBC Div. B 3.12.4.1. Water Circulation Systems(1) In addition to the requirements of this Subsection, the water circulation system of a public spa shall comply with the requirements of Sentences 3.11.8.1.(2), (3), (6), (7), (9), (10), (11), (13) and (20). (2) A public spa shall be equipped with a water circulation system that is capable of filtering, disinfecting…). The emergency stop button must be within 15 m of the spa (3.12.5.1.OBC Div. B 3.12.5.1. Lighting and Emergency Provisions(1) In addition to the requirements of this Subsection, public spas shall comply with the requirements of Sentences 3.11.10.1.(1) to (6). (2) An emergency telephone directly connected to an emergency service or to the local telephone utility shall be installed within 30 m of the public spa. (3) All pumps used in a…).

Practice this topic

Tents and air-supported structures

Tents are exempt from Division B except for Subsection 3.14.1. (OBC Div. B 3.14.1.1.OBC Div. B 3.14.1.1. Application(1) Except as provided in this Subsection, tents are exempt from complying with the requirements of this Division.). Small tents get further relief: the egress, bleacher and sanitary articles do not apply to a tent of not more than 225 m² with no bleachers and no sidewalls (3.14.1.2.OBC Div. B 3.14.1.2. General(1) Except as provided in Sentence (2), the requirements of this Subsection shall apply to all tents. (2) Articles 3.14.1.3., 3.14.1.7. and 3.14.1.8. do not apply to tents that (a) do not exceed 225 m² in ground area, (b) do not exceed 225 m² in aggregate ground area and are closer than 3 m apart, (c) do not contain…). Tents must be at least 3 m from the property line and, generally, from other structures (3.14.1.4.OBC Div. B 3.14.1.4. Clearance to Other Structures(1) Tents shall not be erected closer than 3 m to the property line. (2) Except as provided in Sentences (3) to (6), tents shall not be erected closer than 3 m to other tents or structures on the same property. (3) A walkway between a building and a tent occupied by the public is permitted provided (a) the tent is not…), and the ground inside and 3 m around must be cleared of combustible material.

Air-supported structures cannot house Group B, Group C or Group F, Division 1 occupancies or classrooms (OBC Div. B 3.14.2.2.OBC Div. B 3.14.2.2. General(1) Air-supported structures shall not be used for Groups B, C or Group F, Division 1 major occupancies or for classrooms. (2) Except where no fire separation is required between major occupancies, air-supported structures shall contain not more than one major occupancy. (3) Except as provided in Sentence (5)…). An assembly use with more than 200 persons needs emergency air supply able to run one blower for 4 h (3.14.2.6.OBC Div. B 3.14.2.6. Emergency Air Supply(1) An air-supported structure designed for an assembly occupancy with an occupant load of more than 200 persons shall have either an automatic emergency engine-generator set capable of powering one blower continuously for 4 h, or a supplementary blower powered by an automatic internal combustion engine.).

Practice this topic

Signs

Section 3.15. covers the erection of signs, except traffic signs, window signs, small directional signs, signs painted on a building and signs left to municipal approval (OBC Div. B 3.15.1.2.OBC Div. B 3.15.1.2. Exceptions(1) The following signs shall not be subject to the provisions of this Section (a) signs for regulating traffic or similar devices, legal notices or warnings at railroad crossings, (b) signs in display windows including writing, representation, painting or lettering directly on the surface of any window or door, or…). Sign structures are designed to Part 4. A sign over a sidewalk needs at least 2,400 mm of clearance underneath, and a sign face within 600 mm of a driveway or parking area needs 4.25 m unless vehicle height is permanently restricted (3.15.5.2.OBC Div. B 3.15.5.2. Clearance for Exterior Signs(1) An exterior sign shall not be located so as to overhang a sidewalk or other pedestrian walkway unless the vertical distance, measured from the bottom of the overhanging portion of the sign to the surface of the sidewalk, is at least 2,400 mm. (2) Except as provided in Sentence (3), a sign face shall not be located…). Plastic sign faces over noncombustible cladding are limited to 30% of the storey's wall area and 15 m² or 1,200 mm high per storey (3.15.4.1.OBC Div. B 3.15.4.1. Combustible Sign Faces(1) Plastic materials used in the construction of sign faces shall (a) have an average burning rate not greater than (i) 65 mm/min in sheets 1.5 mm thick when tested in accordance with ASTM D635, "Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position", or (ii)…). Signs in exits need a flame-spread rating of not more than 25.

Practice this topic

Shelf and rack storage systems

A shelf and rack storage system is a self-contained structural system with elevated platforms or walkways for staff (OBC Div. A 1.4.1.2.OBC Div. A 1.4.1.2.(1) Shelf and rack storage systemShelf and rack storage system means a self-contained structural system within a building, having one or more elevated platforms or walkway levels for personnel access that may also support conveyors and other material handling, storage and distribution equipment.). It must not be used for production or manufacturing, cannot be in a high-hazard industrial occupancy, and is limited to 24 m in height (7 m for plastics and rubber tires) (OBC Div. B 3.16.1.2.OBC Div. B 3.16.1.2. General(1) A shelf and rack storage system shall not be designed for production, manufacturing, assembling, disassembling or ancillary administrative functions. (2) A shelf and rack storage system may be designed for the storage, accessing, retrieval, packing and distribution of commodities. (3) A high-hazard industrial…). A sprinkler system is required, including under all platforms and walkways (3.16.1.6.OBC Div. B 3.16.1.6. Sprinkler System(1) An automatic sprinkler system conforming to this Article shall be installed in a floor area containing a shelf and rack storage system. (2) The automatic sprinkler system shall be designed, constructed, installed and tested in conformance with NFPA 13, "Standard for the Installation of Sprinkler Systems" or the…). Each platform level generally needs two exits, travel distance on a platform to an exit is limited to 45 m, aisles are at least 760 mm clear, and dead-end aisles are limited to 9 m (3.16.1.7.OBC Div. B 3.16.1.7. Exits and Means of Egress(1) Except as permitted in Sentences (2) and (3), every walkway or platform level shall be provided with no fewer than two exits conforming to Section 3.4. (2) An access to exit from an elevated platform level may be provided by means of open unenclosed stairs serving (a) not more than four platform levels, the…).

Practice this topic

Common traps

  • Calling a pool for a 4-unit building a Class B public pool. Fewer than six units means it is not a public pool at all.
  • Mixing the pool deck slope ranges: outdoor 2% to 4%, indoor 1% to 4%.
  • Applying normal occupant load rules to self-storage. 3.10.2.2. switches them off.
  • Forgetting that 3.10.3. and 3.10.4. split on whether the building is one storey without a basement or mezzanine.
  • Assuming an air-supported structure can house a classroom. It cannot.

Chapter review

Chapter at a glance

One line per section: the idea to carry into the exam. Then the answers that most often catch candidates out.

  • Self-service storage buildings

    A self-service storage building is one that gives individual storage spaces to the public and is open to the public only for that purpose.

  • Public pools and public spas

    A public pool excludes, among others, pools serving fewer than six dwelling units, wading pools, hydro-massage pools and water slide receiving basins.

  • Tents and air-supported structures

    Tents are exempt from Division B except for Subsection 3.14.1.. Small tents get further relief: the egress, bleacher and sanitary articles do not apply to a tent of not more than…

  • Signs

    Section 3.15. covers the erection of signs, except traffic signs, window signs, small directional signs, signs painted on a building and signs left to municipal approval.

  • Shelf and rack storage systems

    A shelf and rack storage system is a self-contained structural system with elevated platforms or walkways for staff.

Usual exam traps

  • Calling a pool for a 4-unit building a Class B public pool. Fewer than six units means it is not a public pool at all.
  • Mixing the pool deck slope ranges: outdoor 2% to 4%, indoor 1% to 4%.
  • Applying normal occupant load rules to self-storage. 3.10.2.2. switches them off.
  • Forgetting that 3.10.3. and 3.10.4. split on whether the building is one storey without a basement or mezzanine.
  • Assuming an air-supported structure can house a classroom. It cannot.

Practice this chapter

Questions on Special buildings and structures (Part 3), in the exam format, every answer explained and cited to its article. Sign in to start; a free account gets the free questions.

Code cited in this chapter

Based on the official 2024 Building Code Compendium on ontario.ca.

© King's Printer for Ontario, 2024. Reproduced with permission.

  • OBC Div. A 1.4.1.2.(1) Self-service storage building

    Self-service storage building means a building that is used to provide individual storage spaces to the public and that is open to the public only for those purposes.

    Open OBC Div. A 1.4.1.2.(1) in the code viewer
  • OBC Div. B 3.10.2.1. Occupancy Classification

    (1)A self-service storage building

    (a)shall comply with the requirements for a Group F, Division 2 major occupancy, and

    (b)shall not contain a Group F, Division 1 occupancy.

    Open OBC Div. B 3.10.2.1. in the code viewer
  • OBC Div. B 3.10.2.2. Occupant Load

    (1)The requirements based on occupant load shall not apply.

    Open OBC Div. B 3.10.2.2. in the code viewer
  • OBC Div. B 3.10.3.2. Spatial Separations

    (1)Except as provided in Sentence (2), the requirements in Subsection 3.2.3. shall apply.

    (2)The distance between buildings shall be not less than 9 m.

    Open OBC Div. B 3.10.3.2. in the code viewer
  • OBC Div. B 3.10.3.3. Fire Alarm Systems

    (1)Except as provided in Sentences (2) and (3), the requirements in Subsection 3.2.4. shall apply.

    (2)A fire alarm system shall be installed.

    (3)Within the first storey, manual stations are required only in corridors.

    Open OBC Div. B 3.10.3.3. in the code viewer
  • OBC Div. B 3.10.4.3. Spatial Separations

    (1)Except as provided in Sentences (2) to (4), the requirements in Subsection 3.2.3. shall apply.

    (2)Where the building area conforms to Clause 3.10.4.2.(1)(b), the limiting distance requirements shall not apply between individual buildings.

    (3)Where the building area conforms to Clause 3.10.4.2.(1)(c),

    (a)the limiting distance requirements shall apply between each group of buildings, but not between individual buildings within a group, and

    (b)the distance between each group of buildings shall be not less than 9 m.

    (4)The distance between individual buildings within a group shall be not less than 6 m.

    Open OBC Div. B 3.10.4.3. in the code viewer
  • OBC Div. A 1.4.1.2. Defined Terms

    (1)The words and terms in italics in this Code shall have the following meanings:

    (a)the same meaning as in subsection 1(1) of the Act, if not defined in Clause (b) or (c),

    (b)the same meaning as in each of the following provisions for the purposes described in the provision:

    (i)Sentences 1.4.1.3.(1) and (2) of Division A, and

    (ii)Sentences 3.13.1.2.(1), 7.1.1A.1.(1), 8.1.1.2.(1) and 11.1.1.2.(1) of Division B, or

    (c)the following meaning for the purposes of this Code:

    Absorption trench means an excavation in soil, as defined in Part 8 of Division B, or in leaching bed fill, being part of a leaching bed, in which a distribution pipe or leaching chamber is laid that allows infiltration of the effluent into the soil, as defined in Part 8 of Division B, or leaching bed fill.

    Acceptable solution means a requirement stated in Parts 2 to 12 of Division B.

    Accessible means, when applied to a fixture, connection, plumbing appliance, valve, cleanout or equipment, to be accessible with or without having to first remove an access panel, door or similar obstruction, but a fixture, connection, plumbing appliance, valve, cleanout or equipment is not accessible if access can be gained only by cutting or breaking materials.

    Access to exit means that part of a means of egress within a floor area that provides access to an exit serving the floor area.

    Adaptable seating means a fixed seat or seats designed to facilitate a side transfer from a wheelchair. (See Note A-1.4.1.2.(1))

    Additional circuit vent means a vent pipe that is installed between a circuit vent and a relief vent to provide additional air circulation.

    Adfreezing means the adhesion of soil to a foundation unit resulting from the freezing of soil water. (Also referred to as "frost grip.")

    Agricultural occupancy (Group G) means the occupancy of a building or part thereof that is located on land that is associated with and devoted to the practice of farming, and is used for the purpose of producing crops, raising farm animals, or preparing, marketing, storing or processing agricultural products. (See Note A-1.4.1.2.(1))

    Agricultural occupancy with no human occupants (Group G, Division 4) means an agricultural occupancy that is not intended to be occupied by persons under normal use and is generally used for the storage of agricultural materials and by-products. (See Note A-1.4.1.2.(1))

    Air admittance valve means a one-way valve designed to allow air to enter the drainage system when the pressure in the plumbing system is less than the atmospheric pressure.

    Air barrier system means the assembly installed to provide a continuous barrier to the movement of air.

    Air break means the unobstructed vertical distance between the lowest point of an indirectly connected waste pipe and the flood level rim of the fixture into which it discharges.

    Air-conditioning means the process of treating air in a space to control simultaneously its temperature, humidity, cleanliness, and distribution to meet the comfort requirements of the occupants of the space.

    Air gap means the unobstructed vertical distance through air between the lowest point of a water supply outlet and the flood level rim of the fixture or device into which the outlet discharges.

    Air-supported structure means a structure consisting of a pliable membrane that achieves and maintains its shape and support by internal air pressure.

    Alarm signal means an audible signal transmitted throughout a zone or zones or throughout a building to advise occupants that a fire emergency exists.

    Alert signal means an audible signal to advise designated persons of a fire emergency.

    Allowable bearing pressure means the maximum pressure that may be safely applied to a soil or rock by the foundation unit considered in design under expected loading and subsurface conditions.

    Allowable load means the maximum load that may be safely applied to a foundation unit considered in design under expected loading and subsurface conditions.

    Alloyed zinc means an alloy of zinc having the corrosion resistance and physical properties of an alloy containing 0.15% titanium, 0.74% copper and 99.11% zinc, and so tempered as to be capable of being formed into the shape required for a watertight joint.

    Alternative solution means a substitute for an acceptable solution.

    Apparent sound transmission class (ASTC) means a single number rating of the airborne sound attenuation of building assemblies separating two adjoining spaces, taking into account both the direct and flanking sound transmission paths. (See Note A-1.4.1.2.(1)) (See also Note A-9.11. of Division B)

    Appliance means a device to convert fuel into energy and includes all components, controls, wiring and piping required to be part of the device by the applicable standard referred to in this Code.

    Architect means the holder of a licence, a certificate of practice or a temporary licence under the Architects Act.

    Area affected by a significant drinking water threat means an area described in Clause 1.10.2.3.(2)(b) of Division C.

    Artesian groundwater means a confined body of water under pressure in the ground.

    As constructed plans means construction plans and specifications that show the building and the location of the building on the property as the building has been constructed.

    Assembly occupancy (Group A) means the occupancy or the use of a building or part thereof by a gathering of persons for civic, political, travel, religious, social, educational, recreational or like purposes, or for the consumption of food or drink.

    Attic or roof space means the space between the roof and the ceiling of the top storey or between a dwarf wall and a sloping roof.

    auxiliary water supply means, when applied to premises, any water supply on or available to the premises other than the primary potable water supply for the premises.

    Backflow means a flowing back or reversal of the normal direction of the flow.

    Backflow preventer means a device or a method that prevents backflow in a water distribution system.

    Back pressure means pressure higher than the supply pressure.

    Back-siphonage means backflow caused by a negative pressure in the supply system.

    Back-siphonage preventer means a device or a method that prevents back-siphonage in a water distribution system.

    Back vent means a pipe that is installed to vent a trap off the horizontal section of a fixture drain or the vertical leg of a water closet or other fixture that has an integral siphonic flushing action and "back vented" has a corresponding meaning.

    Backwater valve means a check valve designed for use in a gravity drainage system.

    Barrier-free means, when applied to a building and its facilities, that the building and its facilities can be approached, entered and used by persons with physical or sensory disabilities.

    Basement means a storey or storeys of a building located below the first storey.

    Bathroom group means a group of plumbing fixtures installed in the same room, consisting of one domestic-type lavatory, one water closet and either one bathtub, with or without a shower, or one one-headed shower.

    Bearing surface means the contact surface between a foundation unit and the soil or rock upon which it bears.

    Boarding, lodging or rooming house means a building

    (a) that has a building height not exceeding three storeys and a building area not exceeding 600 m²,

    (b) in which lodging is provided for more than four persons in return for remuneration or for the provision of services or for both, and

    (c) in which the lodging rooms do not have both bathrooms and kitchen facilities for the exclusive use of individual occupants.

    Boiler means an appliance intended to supply hot water or steam for space heating, processing or power purposes.

    Bottle trap means a trap that retains water in a closed chamber and that seals the water by submerging the inlet pipe in the liquids or by a partition submerged in the liquids.

    Braced wall band means an imaginary continuous straight band extending vertically and horizontally through the building or part of the building, within which braced wall panels are constructed.

    Braced wall panel means a portion of a wood-frame wall where bracing, sheathing, cladding or interior finish is designed and installed to provide the required resistance to lateral loads due to wind or earthquake.

    Branch means a sanitary drainage pipe that is connected at its upstream end to the junction of two or more sanitary drainage pipes or to a stack connected at its downstream end to another branch, a sump, a stack or a building drain.

    Branch vent means a vent pipe that is connected at its lower end to the junction of two or more vent pipes and at its upper end either to another branch vent, or to a stack vent, vent stack or vent header, or terminates in open air.

    Breeching means a flue pipe or chamber for receiving flue gases from one or more flue connections and for discharging these gases through a single flue connection.

    Building area means the greatest horizontal area of a building above grade within the outside surface of exterior walls or within the outside surface of exterior walls and the centre line of firewalls.

    Building Code website means the website at www.ontario.ca/buildingcode.

    Building control valve means the valve on a water system that controls the flow of potable water from the water service pipe to the water distribution system.

    Building drain means the lowest horizontal piping, including any vertical offset, that conducts sewage, clear water waste or storm water by gravity to a building sewer.

    Building height (in storeys) means the number of storeys contained between the roof and the floor of the first storey.

    Building sewer means a pipe that is connected to a building drain 1 m outside a wall of a building and that leads to a public sewer or private sewage disposal system.

    Building trap means a trap that is installed in a building drain or sanitary building sewer to prevent the circulation of air between the sanitary drainage system and a public sewer.

    Business and personal services occupancy (Group D) means the occupancy or use of a building or part thereof for the transaction of business or the provision of professional or personal services.

    Caisson (see Pile).

    Camp for housing of workers means a camp in which buildings or other structures or premises are used to accommodate five or more employees.

    Campground means land or premises used as an overnight camping facility that is not a recreational camp.

    Canopy means a roof-like structure projecting more than 300 mm from the exterior face of the building.

    Carbon dioxide equivalent means a measure used to compare the impact of various greenhouse gases based on their global warming potential.

    Carbon monoxide alarm means a carbon monoxide detection device with an integral audible alarm device designed to sound an alarm within the room, suite or space in which it is located when the concentration of airborne carbon monoxide exceeds a pre-determined level and duration.

    Care and treatment occupancy (Group B, Division 2) means an occupancy in which persons receive special care and treatment.

    Care occupancy (Group B, Division 3) means an occupancy, other than a retirement home, in which special care is provided by a facility, directly through its staff or indirectly through another provider, to residents of the facility

    (a) who require special care because of cognitive or physical limitations, and

    (b) who, as a result of those limitations, would be incapable of evacuating the occupancy, if necessary, without the assistance of another person.

    Cavity wall means a construction of masonry units laid with a cavity between the wythes. The wythes are tied together with metal ties or bonding units, and are relied on to act together in resisting lateral loads.

    Certificate for the occupancy of a building described in Sentence 1.3.3.4.(3) of Division C means a certificate described in Sentence 3.7.4.3.(6) of Division C.

    Certificate for the occupancy of a building described in Sentence 1.3.3.5.(1) of Division C means a certificate described in Sentence 3.7.4.3.(7) of Division C.

    Certificate for the occupancy of a building not fully completed means a certificate described in Sentence 3.7.4.3.(5) of Division C.

    Chamber means a structure in a shallow buried trench that is constructed with an open bottom and that contains a pressurized distribution pipe.

    Check valve means a valve that permits flow in only one direction and prevents a return flow.

    Child care centre means a child care centre as defined in subsection 2 (1) of the Child Care and Early Years Act, 2014.

    Chimney means a primarily vertical shaft enclosing at least one flue for conducting flue gases to the outdoors.

    Chimney liner means a conduit containing a chimney flue used as a lining of a masonry or concrete chimney.

    Circuit vent means a vent pipe that serves a number of fixtures and connects to the fixture drain of the most upstream fixture, and "circuit vented" has a corresponding meaning.

    Class 1 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets, is directly connected to the public water supply main only, has no pumps or reservoirs and in which the sprinkler drains discharge to the atmosphere, to dry wells or to other safe outlets.

    Class 2 fire sprinkler/standpipe system means a Class 1 fire sprinkler/standpipe system that includes a booster pump in its connection to the public water supply main.

    Class 3 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys potable water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets and that is directly connected to the public water supply main as well as to one or more of the following storage facilities, which are filled from the public water supply main only: elevated water storage, fire pumps supplying water from aboveground covered reservoirs or pressure tanks. The water in this sprinkler/standpipe system must be maintained in potable condition.

    Class 4 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets and is directly connected to the public water supply main (similar to Class 1 and Class 2 fire sprinkler/standpipe systems) and to an auxiliary water supply dedicated to fire department use that is located within 520 m of a pumper connection.

    Class 5 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets, is directly connected to the public water supply main and also interconnected with an auxiliary water supply.

    Class 6 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets and acts as a combined industrial water supply and fire protection system that is supplied from the public water supply main only, with or without gravity storage or pump suction tanks.

    Cleanout means a fitting access in a drainage system or venting system that is installed to provide access for cleaning and inspection and that is provided with a readily replaceable air tight cover.

    Clean water means water that has passed through a recirculation system.

    Clear-water waste means waste water with impurity levels that will not be harmful to health and may include cooling water and condensate drainage from refrigeration and air-conditioning equipment and cooled condensate from steam heating systems, but does not include storm water.

    Closed container means a container so sealed by means of a lid or other device that neither liquid nor vapour will escape from it at ordinary temperatures.

    Closure means a device or assembly for closing an opening through a fire separation or an exterior wall, such as a door, a shutter, a damper, wired glass or glass block, and includes all components such as hardware, closing devices, frames and anchors.

    Combustible means that a material fails to meet the acceptance criteria of CAN/ULC-S114, "Standard Method of Test for Determination of Non-Combustibility in Building Materials."

    Combustible construction means that type of construction that does not meet the requirements for noncombustible construction or encapsulated mass timber construction.

    Combustible dusts means dusts and particles that are ignitable and liable to produce an explosion.

    Combustible fibres means finely divided, combustible vegetable or animal fibres and thin sheets or flakes of such materials which, in a loose, unbaled condition, present a flash fire hazard, including cotton, wool, hemp, sisal, jute, kapok, paper and cloth.

    Combustible liquid means a liquid having a flash point at or above 37.8°C and below 93.3°C.

    Compliance alternative means a substitute for a requirement in another Part of Division B that is listed in Part 10 or 11 of Division B, and "C.A." has a corresponding meaning.

    Compressed gas means

    (a) any contained mixture or material having a vapour pressure exceeding one or both of the following:

    (i)275.8 kPa (absolute) at 21°C, or

    (ii)717 kPa (absolute) at 54°C, or

    (b) any liquid having a vapour pressure exceeding 275.8 kPa (absolute) at 37.8°C.

    Computer room means a room

    (a) that contains electronic computer or data processing equipment such as main frame type,

    (b) that is separated from the remainder of the building for the purpose of controlling the air quality in the room by a self-contained climate control system, and

    (c) that has an occupant load of not more than one person for each 40 m² of the room.

    Conditioned space means any space within a building, the temperature of which is controlled to limit variation in response to the exterior ambient temperature by the provision, either directly or indirectly, of heating or cooling over substantial portions of the year.

    Construction index means a level on a scale of 1 to 8 determined in accordance with Table 11.2.1.1.-A of Division B designating the expected performance level of the building structure with respect to the type of construction and fire protection of an existing building, and "C.I." has a corresponding meaning.

    Contained use area means a supervised area containing one or more rooms in which occupant movement is restricted to a single room by security measures not under the control of the occupant.

    Continuous vent means a vent pipe that is an extension of a vertical section of a branch or fixture drain.

    Cooktop means a cooking surface having one or more burners or heating elements.

    Critical level means the level of submergence at which a back-siphonage preventer ceases to prevent back-siphonage.

    Dangerous goods means products, materials or substances that are

    (a) regulated by TC SOR/2001-286, "Transportation of Dangerous Goods Regulations (TDGR)", or (See Table 3.2.7.1. of Division B of CCBFC NRCC-CONST-56437E, "National Fire Code of Canada")

    (b) classified as controlled products under HC SOR/2015-17, "Hazardous Products Regulations". (See Note A-Table 3.2.7.1. of Division B of CCBFC NRCC-CONST-56437E, "National Fire Code of Canada")

    Day camp means a camp or resort that admits persons for a continuous period not exceeding 24 hours.

    Dead end means a pipe that terminates with a closed fitting.

    Dead load means the weight of all permanent structural and non-structural components of a building.

    Deep foundation means a foundation unit that provides support for a building by transferring loads either by end-bearing to soil or rock at considerable depth below the building, or by adhesion or friction, or both, in the soil or rock in which it is placed. Piles are the most common type of deep foundation.

    Demountable stage means a structure that

    (a) consists of one or more platforms together with any wall, roof or other structures attached to or located on any of the platforms,

    (b) is intended to be used for public or private performances or events, other than performances or events associated with movie or television productions,

    (c) is intended to be erected, assembled or installed for a limited specified time,

    (d)is capable of being dismantled at its location and moved to be reconstituted elsewhere or is erected for one-time use,

    (e)is not located inside a fully enclosed building,

    (f)is primarily for use by performers and workers, and

    (g)may or may not be mounted on wheels.

    Demountable support structure means any structure that

    (a) is capable of supporting banners, stage sets, props, sound equipment, lighting equipment or other equipment,

    (b) is intended to be used for public or private performances or events, other than performances or events associated with movie or television productions,

    (c) is intended to be erected, assembled or installed for a limited specified time,

    (d) is capable of being dismantled at its location and moved to be reconstituted elsewhere or is erected for one-time use,

    (e) is not attached to or located on a demountable stage,

    (f) is not located inside a fully enclosed building,

    (g) is primarily for use by performers and workers, and

    (h)may or may not be mounted on wheels.

    Design activities means the activities described in subsection 15.11(5) of the Act.

    Design bearing pressure means the pressure applied by a foundation unit to soil or rock , which pressure is not greater than the allowable bearing pressure.

    Design capacity means, in the definition of sewage system , the total daily design sanitary sewage flow determined in accordance with Article 8.2.1.3. of Division B.

    Designer means the person responsible for the design.

    Design load means the load applied to a foundation unit , which load is not greater than the allowable load.

    Detention occupancy (Group B, Division 1) means the occupancy by persons who are restrained from or are incapable of evacuating to a safe location without the assistance of another person because of security measures not under their control.

    Developed length means, the length along the centre line of the pipe and fittings.

    Direct-vented (as applying to a fuel-fired space- or water-heating appliance) means an appliance and its venting system in which all the combustion air is supplied directly from the outdoors and the products of combustion are vented directly to the outdoors via independent, totally enclosed passageways connected directly to the appliance.

    Directly connected means physically connected in such a way that neither water or gas can escape from the connection.

    Distilled beverage alcohol means a beverage that is produced by fermentation and contains more than 20% by volume of water-miscible alcohol.

    Distillery means a process plant where distilled beverage alcohols are produced, concentrated or otherwise processed, and includes facilities on the same site where the concentrated products may be blended, mixed, stored or packaged.

    Distributing pipe means a pipe or piping in a water distribution system.

    Distribution box means a device for ensuring that effluent from a treatment unit is distributed in equal amounts to each line of distribution pipe or leaching chamber in a leaching bed.

    Distribution pipe means a line or lines of perforated or open jointed pipe or tile installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.

    Diving board means a flexible board.

    Diving platform means a rigid platform that is not a starting platform.

    Drainage system means an assembly of pipes, fittings, fixtures and appurtenances on a property that is used to convey sewage and clear water waste to a main sewer or a private sewage disposal system, and includes a private sewer, but does not include subsoil drainage piping.

    Drinking water system has the same meaning as in subsection 2(1) of the Safe Drinking Water Act, 2002.

    Drum trap means a trap whose inlet and outlet are in the sides of the cylindrical body of the trap.

    Dual vent means a vent pipe that serves two fixtures and connects at the junction of the trap arms.

    Dwelling unit means a suite operated as a housekeeping unit, used or intended to be used by one or more persons and usually containing cooking, eating, living, sleeping and sanitary facilities.

    Earth pit privy means a latrine consisting of an excavation in the ground surmounted by a superstructure.

    Effluent means sanitary sewage that has passed through a treatment unit.

    Electric space heating means an electric energy source that provides more than 10 percent of the heating capacity provided for a building and includes

    (a) electric resistance unitary baseboard heating,

    (b) electric resistance unitary cabinet heating,

    (c) electric resistance ceiling cable or floor cable heating,

    (d) electric resistance central furnace heating,

    (e) electric hot water space heating, and

    (f) air source heat pumps in combination with electric resistance backup heating.

    Encapsulated mass timber construction means that type of construction in which a degree of fire safety is attained by the use of encapsulated mass timber elements with an encapsulation rating and minimum dimensions for structural members and other building assemblies.

    Encapsulation rating means the time in minutes that a material or assembly of materials will delay the ignition and combustion of encapsulated mass timber elements when it is exposed to fire under specified conditions of test and performance criteria, or as otherwise prescribed by this Code.

    Excavation means the space created by the removal of soil, rock or fill for the purposes of construction.

    Exhaust duct means a duct through which air is conveyed from a room or space to the outdoors.

    Exit means that part of a means of egress, including doorways, that leads from the floor areait serves to a separate building, an open public thoroughfare, or an exterior open space protected from fire exposure from the building and having access to an open public thoroughfare. (See Note A-1.4.1.2.(1))

    Exit level means the level of an exit stairway at which an exterior exit door or exit passageway leads to the exterior.

    Exit storey (as applying to Subsection 3.2.6. of Division B) means a storey having an exterior exit door.

    Exposing building face means that part of the exterior wall of a building that faces one direction and is located between ground level and the ceiling of its top storey or, where a building is divided into fire compartments, the exterior wall of a fire compartment that faces one direction.

    Exterior cladding means those components of a building that are exposed to the outdoor environment and are intended to provide protection against wind, water or vapour.

    Factory-built chimney means a chimney consisting entirely of factory-made parts, each designed to be assembled with the other without requiring fabrication on site.

    Farm building means a building or part thereof that contains an agricultural occupancy. (See Note A-1.4.1.2.(1))

    Fill means soil, rock, rubble, industrial waste such as slag, organic material or a combination of these that is transported and placed on the natural surface of soil or rock or organic terrain. It may or may not be compacted.

    Fire block means a material, component or system that restricts the spread of fire within a concealed space or from a concealed space to an adjacent space.

    Fire compartment means an enclosed space in a building that is separated from all other parts of the building by enclosing construction providing a fire separation having a required fire-resistance rating.

    Fire damper means a closure consisting of a damper that is installed in an air distribution system or a wall or floor assembly and that is normally held open but designed to close automatically in the event of a fire in order to maintain the integrity of the fire separation.

    Fire detector means a device that detects a fire condition and automatically initiates an electrical signal to actuate an alert signal or alarm signal and includes heat detectors and smoke detectors.

    Fire load (as applying to an occupancy) means the combustible contents of a room or floor area expressed in terms of the average weight of combustible materials per unit area, from which the potential heat liberation may be calculated based on the calorific value of the materials, and includes the furnishings, finished floor, wall and ceiling finishes, trim and temporary and movable partitions.

    Fire-protection rating means the time in minutes or hours that a closure will withstand the passage of flame when exposed to fire under specified conditions of test and performance criteria, or as otherwise prescribed in this Code.

    Fire-resistance rating means the time in minutes or hours that a material or assembly of materials will withstand the passage of flame and the transmission of heat when exposed to fire under specified conditions of test and performance criteria, or as determined by extension or interpretation of information derived therefrom as prescribed in this Code. (See Sentence 1.2.1.(2) in MMAH Supplementary Standard SB-2)

    Fire-retardant-treated wood means wood or a wood product that has had its surface-burning characteristics, such as flame spread, rate of fuel contribution and density of smoke developed, reduced by impregnation with fire-retardant chemicals.

    Fire separation means a construction assembly that acts as a barrier against the spread of fire. (See Note A-1.4.1.2.(1))

    Fire service main means a pipe and its appurtenances that are connected to a source of water and that are located on a property

    (a) between the source of water and the base of the riser of a water-based fire protection system,

    (b) between the source of water and inlets to foam making systems,

    (c) between the source of water and the base elbow of private hydrants or monitor nozzles,

    (d) as fire pump suction and discharge piping not within a building, or

    (e) beginning at the inlet side of the check valve on a gravity or pressure tank.

    Fire service pipe means a pipe that conveys water from a public water main or private water source to the inside of a building for the purpose of supplying the fire sprinkler or standpipe systems.

    Firestop means a system consisting of a material, component and means of support used to fill gaps between fire separations or between fire separations and other assemblies, or used around items that wholly or partially penetrate a fire separation.

    Fire stop flap means a device intended for use in horizontal assemblies required to have a fire-resistance rating and incorporating protective ceiling membranes that operates to close off a duct opening through the membrane in the event of a fire

    Firewall means a type of fire separation of noncombustible construction that subdivides a building or separates adjoining buildings to resist the spread of fire and that has a fire-resistance rating as prescribed in this Code and has structural stability to remain intact under fire conditions for the required fire-rated time.

    First storey means the storey that has its floor closest to grade and its ceiling more than 1.8 m above grade.

    Fixture means a receptacle, appliance, apparatus or other device that discharges sewage or clear water waste, and includes a floor drain.

    Fixture drain means the pipe that connects a trap serving a fixture to another part of a drainage system.

    Fixture outlet pipe means a pipe that connects the waste opening of a fixture to the trap serving the fixture.

    Fixture unit, as applying to a drainage system, means the unit of measure based on the rate of discharge, time of operation and frequency of use of a fixture that expresses the hydraulic load that is imposed by that fixture on the drainage system.

    Fixture unit, as applying to water distribution systems, means the unit of measure based on the rate of supply, time of operation and frequency of use of a fixture or outlet that expresses the hydraulic load that is imposed by that fixture or outlet on the supply system.

    Flame-spread rating means an index or classification indicating the extent of spread-of-flame on the surface of a material or an assembly of materials as determined in a standard fire test as prescribed in this Code.

    Flammable liquid means a liquid having a flash point below 37.8°C and having a vapour pressure not more than 275.8 kPa (absolute) at 37.8°C as determined by ASTM D323, "Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method)."

    Flash point means the minimum temperature at which a liquid within a container gives off vapour in sufficient concentration to form an ignitable mixture with air near the surface of the liquid.

    Flight means a series of steps between landings. (See Note A-1.4.1.2.(1))

    Flood level rim means the top edge at which water can overflow from a fixture or device.

    Floor area means the space on any storey of a building between exterior walls and required firewalls, including the space occupied by interior walls and partitions, but not including exits, vertical service spaces, and their enclosing assemblies.

    Flow control roof drain means a roof drain that restricts the flow of storm water into the storm drainage system.

    Flue means an enclosed passageway for conveying flue gases.

    Flue collar means the portion of a fuel-fired appliance designed for the attachment of the flue pipe or breeching.

    Flue pipe means the pipe connecting the flue collar of an appliance to a chimney.

    Food premises means a floor area where food or drink for human consumption, or an ingredient of food or drink for human consumption, is manufactured, processed, prepared, stored, displayed, handled, served, distributed, sold or offered for sale, but does not include

    (a) a private residence,

    (b) a boarding house that provides meals for fewer than 10 boarders,

    (c) a building to which Ontario Regulation 502/17 (Camps in Unorganized Territory) or Ontario Regulation 503/17 (Recreational Camps) made under the Health Protection and Promotion Act applies,

    (d) a plant, as defined in the Milk Act, that is required to be operated under the authority of a licence issued under that Act,

    (e) premises where a licensed activity, as defined in the Food Safety and Quality Act, 2001, is carried on by a person who is required to hold a licence issued under that Act,

    (f) an egg-grading station or an egg-processing station, as defined in subsection 1(1) of Ontario Regulation 171/10 (Eggs and Processed Egg), made under the Food Safety and Quality Act, 2001,

    (g) a floor area occupied by a church, service club or fraternal organization for the purpose of

    (i)preparing meals for special events for its members and personally invited guests, or

    (ii) conducting bake sales, or

    (h) a farm building.

    Forced-air furnace means a furnace equipped with a fan that provides the primary means for the circulation of air.

    Force main means a sanitary drainage pipe through which sanitary sewage is conveyed by mechanical or pneumatic propulsion.

    Foundation means a system or arrangement of foundation units through which the loads from a building are transferred to supporting soil or rock .

    Foundation unit means one of the structural members of the foundation of a building such as a footing, raft or pile.

    Fresh air inlet means a vent pipe that is installed in conjunction with a building trap and terminates outdoors.

    Frost action means the phenomenon that occurs when

    (a) water in soil is subjected to freezing which, because of the water ice phase change or ice lens growth, results in a total volume increase or the build-up of expansive forces under confined conditions or both, and

    (b) the subsequent thawing leads to loss of soil strength and increased compressibility.

    Functional statement means a function set out in Article 3.2.1.1. that a building or an element of a building is intended to perform.

    Furnace means a space-heating appliance using warm air as the heating medium and usually having provision for the attachment of ducts.

    Gaming premises means premises that are a gaming site as defined in the Ontario Lottery and Gaming Corporation Act, 1999.

    Gas vent means that portion of a venting system designed to convey vent gases to the outdoors

    (a) from the vent connector of a gas-fired appliance, or

    (b) directly from the appliance when a vent connector is not used.

    Grade means the average level of proposed or finished ground adjoining a building at all exterior walls.

    Graded lumber means lumber that has been graded and stamped to indicate its grade, as determined by the NLGA, "Standard Grading Rules for Canadian Lumber".

    Greenhouse agricultural occupancy (Group G, Division 3) means an agricultural building or part thereof that is primarily constructed of roofs and walls designed to transmit natural light.

    Greywater means sanitary sewage of domestic origin that is derived from fixtures other than sanitary units.

    Gross area means the total area of all floors above grade measured between the outside surfaces of exterior walls or between the outside surfaces of exterior walls and the centre line of firewalls, except that, in any occupancy other than a residential occupancy, where an access or a building service penetrates a firewall, measurements shall not be taken to the centre line of such firewall.

    Ground water means, when applied to a sewage system, water below the surface of the ground that occupies a zone of the earth's mantle that is saturated with water.

    Ground water table means, when applied to a sewage system, the elevation of the upper surface of the ground water existing in the area of the sewage system.

    Groundwater means a free standing body of water in the ground.

    Groundwater level (groundwater table) means the top surface of a free standing body of water in the ground.

    Guard means a protective barrier, with or without openings through it, that is around openings in floors or at the open sides of stairs, landings, balconies, mezzanines, galleries, raised walkways or other locations to prevent accidental falls from one level to another.

    Hauled sewage means sanitary sewage that

    (a) is not finally disposed of at the site where it is produced and is not conveyed by a sewer to sewage works, and

    (b) is stored or retained at the site where it is produced for periodic collection, handling, treatment, transportation, storage or processing prior to final disposal at a place other than where it was produced,

    and includes sanitary sewage that is removed from a sewage system for the purpose of cleaning or maintaining the system.

    Hauled sewage system means works, installations, equipment, operations and land used in connection with the collection, handling, treatment, transportation, storage, processing and disposal of hauled sewage, as regulated under the Environmental Protection Act.

    Hazard index means a level on a scale of 1 to 8 determined in accordance with Tables 11.2.1.1.-B to 11.2.1.1.-N of Division B, designating the life safety hazard to occupants of a building based on

    (a) use and occupancy,

    (b) occupant load,

    (c) the use and function of floor spaces,

    (d) the difficulty of egress,

    (e) the fire load of contents, finishes and furnishings,

    (f) the configuration or compartmentation of floor spaces, and

    (g) the size of the building,

    and "H.I." has a corresponding meaning.

    Hazardous classroom means a classroom

    (a) that is supplied with flammable gas,

    (b) that contains hazardous substances such as chemicals or explosive dusts,

    (c) that contains large quantities of combustible materials, or

    (d) where cooking equipment is used.

    Hazardous extraction means a process to remove or separate a substance from a solution or mixture that involves the use of flammable liquids, combustible liquids or flammable gases as solvents in the process.

    Hazardous room means a room containing sufficient quantities of a substance that, because of its chemical nature, may create an atmosphere or condition of imminent hazard to health.

    Header means a vent pipe that connects two or more vent stacks or stack vents to open air.

    Header line means a line of pipe with watertight joints installed in a sewage system for the purpose of distributing effluent from a treatment unit to the distribution pipe in a leaching bed.

    Heat detector means a fire detector designed to operate at a predetermined temperature or rate of temperature rise.

    Heavy timber construction means that type of combustible construction in which a degree of fire safety is attained

    (a) by placing limitations on the sizes of wood structural members and on the thickness and composition of wood floors and roofs, and

    (b) by the avoidance of concealed spaces under floors and roofs.

    Heritage building means a building or part thereof,

    (a) that is identified, or otherwise protected under the Ontario Heritage Act as being of cultural heritage value or interest:

    (b) that has been set apart as a National Historic Site of Canada by the Minister of the Environment for Canada under the Canada National Parks Act (Canada):

    (c) that has been marked or commemorated as a historic place having national historic interest or significance under the Historic Sites and Monuments Act (Canada); or

    (d) that is listed on an inventory of property forming part of the cultural and natural heritage of a place inscribed on the United Nations Educational, Scientific and Cultural Organisation's World Heritage List of sites under the Convention Concerning the Protection of the World Cultural and Natural Heritage. (See Note A-1.4.1.2.(1))

    High ground water table means the highest elevation at which there is physical evidence that the soil, as defined in Part 8 of Division B, or the leaching bed fill has been saturated with water.

    High-hazard agricultural occupancy (Group G, Division 1) means an agricultural occupancy containing sufficient quantities of highly combustible and flammable or explosive materials which, because of their inherent characteristics, constitute a special fire hazard.

    High-hazard industrial occupancy (Group F, Division 1) means an industrial occupancy containing sufficient quantities of highly combustible and flammable or explosive materials which, because of their inherent characteristics, constitute a special fire hazard.

    Holding tank means a tank designed to totally retain all sanitary sewage discharged into it and requiring periodic emptying.

    Home for special care means a home for the care of persons requiring nursing, residential or sheltered care.

    Horizontal branch means that part of a waste pipe that is horizontal and installed to convey the discharge from more than one fixture.

    Horizontal exit means an exit from one building to another by means of a doorway, vestibule, walkway, bridge or balcony.

    Horizontal service space means a space such as an attic, duct, ceiling, roof or crawl space

    (a) that is oriented essentially in a horizontal plane,

    (b) that is concealed and generally inaccessible, and

    (c) through which building service facilities such as pipes, ducts and wiring may pass.

    Hotel means floor areas, a floor area or part of a floor area that contains four or more suites and that provides sleeping accommodation for the travelling public or for recreational purposes.

    Hub drain means a drain opening for indirect liquid wastes

    (a) that does not serve as a floor drain,

    (b) that has the same pipe size, material and venting requirements as a floor drain,

    (c) that has a flood level rim above the floor in which it is installed, and

    (d) that receives wastes that are discharged directly into the drain opening.

    Impeded egress zone means a supervised area in which occupants have free movement but require the release, by security personnel, of security doors at the boundary before they are able to leave the area, but does not include a contained use area.

    Indirectly connected means not directly connected.

    Indirect service water heater means a service water heater that derives its heat from a heating medium such as warm air, steam or hot water.

    Individual vent means a vent pipe that serves one fixture.

    Indoor pool means a public pool where the pool and pool deck are totally or partially covered by a roof.

    Industrial occupancy (Group F) means the occupancy or use of a building or part thereof for the assembling, fabricating, manufacturing, processing, repairing or storing of goods and materials.

    Interceptor means a receptacle that is designed and installed to prevent oil, grease, sand or other materials from passing into a drainage system.

    Interconnected floor space means superimposed floor areas or parts of floor areas in which floor assemblies that are required to be fire separations are penetrated by openings that are not provided with closures.

    Lake Simcoe shoreline has the same meaning as in the Lake Simcoe Protection Plan established under the Lake Simcoe Protection Act, 2008 and dated July, 2009.

    Lake Simcoe watershed has the same meaning as in section 2 of the Lake Simcoe Protection Act, 2008.

    Leaching means dispersal of liquid by downward or lateral drainage or both into permeable soil, as defined in Part 8 of Division B, or leaching bed fill.

    Leaching bed means an absorption system constructed as absorption trenches or as a filter bed, located wholly in ground or raised or partly raised above ground, as required by local conditions, to which effluent from a treatment unit is applied for treatment and disposal and that is composed of

    (a) the soil, as defined in Part 8 of Division B, leaching bed fill or other filter media that is contained between the surface on which the sanitary sewage is applied and the bottom of the bed,

    (b) the leaching chamber or the distribution pipe and the stone or gravel layer in which the distribution pipe is located, and

    (c) the backfill above the distribution pipe or the leaching chamber, including the topsoil and sodding or other anti erosion measure, and the side slopes of any portion elevated above the natural ground elevation.

    Leaching bed fill means unconsolidated material suitable for the construction of a leaching bed, placed in the area of the leaching bed in order to obtain the required unsaturated zone below the distribution pipes or leaching chambers and the required lateral extent such that the effluent is absorbed.

    Leaching chamber means a formed structure with an open bottom and permeable sidewalls installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.

    Leader means a pipe that is installed to carry storm water from a roof to a storm building drain or sewer or other place of disposal.

    Limiting distance means the distance from an exposing building face to a property line, the centre line of a street, lane or public thoroughfare, or to an imaginary line between 2 buildings or fire compartments on the same property, measured at right angles to the exposing building face.

    Listed means equipment or materials included in a list published by a certification organization accredited by the Standards Council of Canada.

    Liquid manure means manure having a dry matter content of less than 18 per cent or a slump of more than 150 millimetres using the Test Method for the Determination of Liquid Waste (slump test) set out in Schedule 9 to Regulation 347 of the Revised Regulations of Ontario, 1990 (General — Waste Management) made under the Environmental Protection Act.

    Live load means a variable load due to the intended use and occupancy that is to be assumed in the design of the structural members of a building. It includes loads due to cranes and the pressure of liquids in containers.

    Live/work unit means a dwelling units having an area of not more than 200 m² that contains a subsidiary business and personal services occupancy or a subsidiary low-hazard industrial occupancy, and which is used and operated by one or more persons of a single household.

    Loadbearing (as applying to a building element) means subjected to or designed to carry loads in addition to its own dead load, excepting a wall element subjected only to wind or earthquake loads in addition to its own dead load.

    Loading rate means the volume in litres of effluent per square metre applied in a single day to soil, as defined in Part 8 of Division B, or leaching bed fill.

    Low-hazard industrial occupancy (Group F, Division 3) means an industrial occupancy in which the combustible content is not more than 50 kg/m² or 1,200 MJ/m² of floor area.

    Low human occupancy means, when applied to a farm building, an occupancy in which the occupant load is not more than one person per 40 m² of floor area during normal use.

    Major occupancy means the principal occupancy for which a building or part thereof is used or intended to be used, and shall be deemed to include the subsidiary occupancies that are an integral part of the principal occupancy. The major occupancy classifications used in this Code are as follows:

    Group A, Division 1 – Assembly occupancies intended for the production and viewing of the performing arts

    Group A, Division 2 – Assembly occupancies not elsewhere classified in Group A

    Group A, Division 3 – Assembly occupancies of the arena type

    Group A, Division 4 — Assembly occupancies in which the occupants are gathered in the open air

    Group B, Division 1 – Detention occupancies in which persons are under restraint or are incapable of self-preservation because of security measures not under their control

    Group B, Division 2 – Care and treatment occupancies

    Group B, Division 3 – Care occupancies

    Group C – Residential occupancies

    Group D – Business and personal services occupancies

    Group E – Mercantile occupancies

    Group F, Division 1 – High-hazard industrial occupancies

    Group F, Division 2 – Medium-hazard industrial occupancies

    Group F, Division 3 – low-hazard industrial occupancies

    Group G, Division 1 – High-hazard agricultural occupancies

    Group G, Division 2 – Agricultural occupancies not elsewhere classified in Group G

    Group G, Division 3 – Greenhouse agricultural occupancies

    Group G, Division 4 – Agricultural occupancies with no human occupants

    Make-up water means water added to a public pool from an external source.

    Marquee means a canopy over an entrance to a building.

    Masonry or concrete chimney means a chimney of brick, stone, concrete or masonry units constructed on site.

    Means of egress means a continuous path of travel provided for the escape of persons from any point in a building or contained open space to a separate building, an open public thoroughfare, or an exterior open space protected from fire exposure from the building and having access to an open public thoroughfare. means of egress includes exits and access to exits.

    Mechanically vented (as applying to a fuel-fired space- or water-heating appliance) means an appliance and its combustion venting system in which the products of combustion are entirely exhausted to the outdoors by a mechanical device, such as a fan, blower or aspirator, upstream or downstream from the combustion zone of the appliance, and the portion of the combustion venting system that is downstream of the fan, blower or aspirator is sealed and does not include draft hoods or draft control devices. (See Note A-1.4.1.2.(1))

    Medium-hazard industrial occupancy (Group F, Division 2) means an industrial occupancy in which the combustible content is more than 50 kg/m² or 1,200 MJ/m² of floor areaand not classified as a high-hazard industrial occupancy.

    Mercantile occupancy (Group E) means the occupancy or use of a building or part thereof for the displaying or selling of retail goods, wares or merchandise.

    Mezzanine means an intermediate floor assembly between the floor and ceiling of any room or storey and includes an interior balcony.

    Mobility assistive device means a mobility assistive device as defined in section 2 of Ontario Regulation 191/11 (Integrated Accessibility Standards) made under the Accessibility for Ontarians with Disabilities Act, 2005.

    Modified pool means a public pool that has a basin-shaped floor sloping downward and inward toward the interior from the rim.

    Modified stack venting means a stack venting arrangement in which the stack vent above the connection of the highest stack vented fixture is reduced in diameter.

    Municipal drinking water system has the same meaning as in subsection 2(1) of the Safe Drinking Water Act, 2002.

    Nominally horizontal means at an angle of less than 45° with the horizontal.

    Nominally vertical means at an angle of not more than 45° with the vertical.

    Nominal pipe size (NPS) means the nominal diameter by which a pipe, fitting, trap or other similar item is commercially designated.

    Noncombustible means that a material meets the acceptance criteria of CAN/ULC-S114, "Standard Method of Test for Determination of Non-Combustibility in Building Materials."

    Noncombustible construction means that type of construction in which a degree of fire safety is attained by the use of noncombustible materials for structural members and other building assemblies.

    Objective means an objective set out in Article 2.2.1.1.

    Occupancy means the use or intended use of a building or part thereof for the shelter or support of persons, animals or property.

    Occupant load means the number of persons for which a building or part thereof is designed.

    Offset means the piping that connects the ends of two pipes that are parallel.

    Offset relief vent means a relief vent that provides additional air circulation upstream and downstream of an offset in a stack.

    Open air means the atmosphere outside a building.

    Open-air storey means a storey in which at least 25% of the total area of its perimeter walls is open to the outdoors in a manner that will provide cross-ventilation to the entire storey.

    Outdoor pool means a public pool that is not an indoor pool.

    Pail privy means a latrine in which the receptacle for human waste consists of a removable container surmounted by a superstructure.

    Partition means an interior wall 1 storey or part-storey in height that is not loadbearing.

    Party wall means a wall

    (a) that is jointly owned and jointly used by two parties under an easement agreement or by a right in law, and

    (b) that is erected at or upon a line separating two parcels of land each of which is, or is capable of being, a separate real estate entity.

    Perched groundwater means a free standing body of water in the ground extending to a limited depth.

    Percolation time means the average time in minutes that is required for water to drop one centimetre during a percolation test or as determined by a soil evaluation or analysis.

    Performance level means the level of performance under which all or part of an existing building functions with respect to its building systems.

    Permanent solid nutrient storage facility has the same meaning as in subsection 1(1) of Ontario Regulation 267/03 (General) made under the Nutrient Management Act, 2002.

    Pharmacy means the premises in a building or the part of the premises in which prescriptions are compounded and dispensed for the public or in which drugs are sold by retail.

    Pile means a slender deep foundation unit made of materials such as wood, steel or concrete or a combination thereof, that is either premanufactured and placed by driving, jacking, jetting or screwing, or cast-in-place in a hole formed by driving, excavating or boring. (Cast-in-place bored piles are often referred to as caissons in Canada.)

    Plenum means a chamber forming part of an air duct system.

    Plumbing appliance means a receptacle or equipment that receives or collects water, liquids or sewage and discharges water, liquid or sewage directly or indirectly to a plumbing system.

    Plumbing system means a system of connected piping, fittings, valves, equipment, fixtures and appurtenances contained in plumbing.

    Point of entry treatment unit has the same meaning as in subsection 1(1) of Ontario Regulation 170/03 (Drinking Water Systems) made under the Safe Drinking Water Act, 2002.

    Pool deck means the area immediately surrounding a public pool.

    Portable privy means a portable latrine in which the receptacle for human body waste and the superstructure are combined structurally into one unit.

    Post-disaster building means a building that is necessary for the provision of essential services to the general public in the event of a disaster and includes

    - hospitals, emergency treatment facilities and blood banks,

    - telephone exchanges,

    - power generating stations and electrical substations,

    - control centres for natural gas distribution,

    - control centres for air, land and marine transportation,

    - water treatment facilities,

    - water storage facilities,

    - water and sewage pumping stations,

    - sewage treatment facilities, and

    - buildings of the following types, unless exempted from this designation by the principal authority:

    - emergency response facilities,

    - fire, rescue and police stations and housing for vehicles, aircraft or boats used for such purposes, and

    - communications facilities, including radio and television stations. (See Note A-1.4.1.2.(1))

    Potable means fit for human consumption.

    Potable water system means the plumbing that conveys potable water.

    Pressurized distribution system means a leaching bed in which the effluent is distributed through the use of pressurized distribution pipes.

    Private sewage disposal system means a sewage system or a sewage works that is not owned and operated by the Crown, a municipality or an organization acceptable to the Director responsible for issuing an environmental compliance approval required under section 53 of the Ontario Water Resources Act.

    Private sewer means a sewer other than a building sewer that

    (a) is not owned or operated by a municipality, the Ministry of the Environment, Conservation and Parks or another public agency,

    (b) receives drainage from more than one sanitary building drain either directly or through more than one sanitary building sewer or receives drainage from more than one storm building drain either directly or through one or more storm building sewers, and connects to a main sewer, or

    (c) serves as a place of disposal on the property, but does not include

    (d) a sewer that carries only the sanitary waste or storm sewage from semi-detached houses each containing not more than two dwelling units,

    (e) a sewer that carries only the sanitary waste or storm sewage from one main building that is of care, care and treatment, detention, commercial or industrial occupancy and one ancillary building, or

    (f) a sewer that carries only the sanitary waste or storm sewage from a row housing complex having five or fewer dwelling units.

    Private use means, when applied to plumbing fixtures, fixtures in residences and apartments, in private bathrooms of hotels, and in similar installations in other buildings for a single household or an individual.

    Private water supply means piping that serves as a source of supply on the property to more than one water service pipe.

    Private water supply system means an assembly of pipes, fittings, valves, equipment and appurtenances that supplies water from a private source to a potable water system.

    Privy vault means a latrine in which the receptacle for human waste consists of a constructed vault from which the waste is periodically removed.

    Process plant means an industrial occupancy where materials, including flammable liquids, combustible liquids or gases, are produced or used in a process.

    Professional engineer means a person who holds a licence or a temporary licence under the Professional Engineers Act.

    Protected floor space means that part of a floor areaprotected from the effects of fire and used as part of a means of egress from an interconnected floor space.

    Public corridor means a corridor that provides access to exit from more than one suite. (See Note A-1.4.1.2.(1))

    Public heritage building means a heritage building where the occupancy in whole or in part includes viewing of the building by the public provided that displays in it are limited to those relevant to the heritage significance of the building.

    Public pool means a structure, basin, chamber or tank containing or intended to contain an artificial body of water for swimming, water sport, water recreation or entertainment, but does not include

    (a) pools operated in conjunction with less than six dwelling units, suites or single family residences or any combination of them,

    (b) pools that are used only for commercial display and demonstration purposes,

    (c) wading pools,

    (d) hydro-massage pools, or

    (e) pools that serve only as receiving basins for persons at the bottom of water slides.

    Public spa means a hydro-massage pool that contains an artificial body of water, that is intended primarily for therapeutic or recreational use, that is not drained, cleaned or refilled before use by each individual and that utilizes hydrojet circulation, air induction bubbles, current flow or a combination of them over the majority of the pool area, but does not include

    (a) wading pools, or

    (b) spas operated in conjunction with less than six dwelling units, suites or single family residences, or any combination of them, for the use of occupants or residents and their visitors.

    Public use means, when applied to plumbing fixtures, fixtures in general washrooms of schools, gymnasiums, hotels, bars, public comfort stations and other installations in which fixtures are installed so that their use is unrestricted.

    Public way means a sidewalk, street, highway, square or other open space to which the public has access, as of right or by invitation, expressed or implied.

    Rainwater means storm sewage runoff that is collected from a roof or the ground, but not from accessible patios and driveways.

    Ramp means a path of travel having a slope steeper than 1 in 20.

    Recirculation system means a system

    (a) that maintains the circulation of water through a public pool by pumps, and

    (b) that provides continuous treatment of the water, including filtration and chlorination or bromination and any other process that may be necessary for the treatment of the water.

    Recreational camp means a camp for recreational activities consisting of one or more buildings or other structures established or maintained as living quarters, with or without charge, for the temporary occupancy of 10 or more persons for five or more days.

    Relief vent means a vent pipe that is used in conjunction with a circuit vent to provide additional air circulation between a drainage system and a venting system.

    Repair garage means a building or part thereof where facilities are provided for the repair or servicing of motor vehicles.

    Residential full flow-through fire sprinkler/standpipe system means an assembly of pipes and fittings installed in the residential portions of a building containing one or two-family dwelling units that conveys water from the water service pipe to outlets in the sprinkler and standpipe systems and is fully integrated into the potable water system to ensure a regular flow of water through all parts of both systems.

    Residential occupancy (Group C) means an occupancy in which sleeping accommodation is provided to residents who are not harboured for the purpose of receiving special care or treatment and are not involuntarily detained and includes an occupancy in which sleeping accommodation is provided to residents of a retirement home.

    Residential partial flow-through sprinkler/standpipe system means an assembly of pipes and fittings installed in the residential portions of a building containing one or two family dwelling units that conveys water from the water service pipe to outlets in the sprinkler and standpipe systems and in which flow occurs during inactive periods of the sprinkler and standpipe systems only through the main header to the water closet located at the farthest point of the two systems.

    Retirement home means a building or part of a building that is a retirement home as defined in subsection 2(1) of the Retirement Homes Act, 2010.

    Return duct means a duct for conveying air from a space being heated, ventilated or air-conditioned back to the heating, ventilating or air-conditioning appliance.

    Rim joist means the outermost member in floor framing, other than blocking, be it parallel, perpendicular or on an angle to the floor joists. (See Note A-1.4.1.2.(1))

    Riser means a water distributing pipe that extends through at least one full storey, as defined in Part 7 of Division B.

    Rock means that portion of the earth's crust that is consolidated, coherent and relatively hard and is a naturally formed, solidly bonded, mass of mineral matter that cannot readily be broken by hand.

    Roof drain means a fitting or device that is installed in the roof to permit storm water to discharge into a leader.

    Roof gutter means an exterior channel installed at the base of a sloped roof to convey storm water.

    Run means the horizontal distance between two adjacent tread nosings on a stair. (See Figure A-9.8.4.-B in Note A-9.8.4. of Division B.)

    Sanitary building drain means a building drain that conducts sewage to a building sewer from the most upstream stack, branch or fixture drain serving a water closet.

    Sanitary building sewer means a pipe that is connected to a sanitary building drain 1,000 mm outside a wall of a building and that conducts sewage to a public sewer or private sewage disposal system.

    Sanitary drainage pipe means all piping that conveys sanitary sewage to a place of disposal, including the sanitary building drain, sanitary building sewer, soil pipe, soil stack, waste stack and waste pipe but not the main sewer or piping in a sewage treatment plant.

    Sanitary drainage system means a drainage system that conducts sewage.

    Sanitary sewage means

    (a) liquid or water borne waste

    (i)of industrial or commercial origin, or

    (ii)of domestic origin, including human body waste, toilet or other bathroom waste, and shower, tub, culinary, sink and laundry waste, or

    (b) liquid or water borne waste discharged from a public pool to a drain.

    Sanitary sewer means a sewer that conducts sewage.

    Sanitary unit means a water closet, urinal, bidet or bedpan washer.

    Secondary suite means a self-contained dwelling units located in a building or portion of a building of only residential occupancy that contains only one other dwelling units and common spaces, and where both dwelling units constitute a single real estate entity. (See Note A-1.4.1.2.(1))

    Self-service storage building means a building that is used to provide individual storage spaces to the public and that is open to the public only for those purposes.

    Septic tank means a watertight vault in which sanitary sewage is collected for the purpose of removing scum, grease and solids from the liquid without the addition of air and in which solids settling and anaerobic digestion of the sanitary sewage takes place.

    Service room means a room provided in a building to contain equipment associated with building services. (See Note A-1.4.1.2.(1))

    Service space means space provided in a building to facilitate or conceal the installation of building service facilities such as chutes, ducts, pipes, shafts or wires.

    Service water heater means a device for heating water for plumbing services.

    Sewage means sanitary sewage or storm sewage.

    Sewage system means

    (a) a chemical toilet, an incinerating toilet, a recirculating toilet, a self-contained portable toilet and all forms of privy, including a portable privy, an earth pit privy, a pail privy, a privy vault and a composting toilet system,

    (b) a greywater system,

    (c) a cesspool,

    (d) a leaching bed system, or

    (e) a system that requires or uses a holding tank for the retention of hauled sewage at the site where it is produced before its collection by a hauled sewage system , where these

    (f) have a design capacity of 10,000 litres per day or less,

    (g) have, in total, a design capacity of 10,000 litres per day or less, where more than one of these are located on a lot or parcel of land, and

    (h) are located wholly within the boundaries of the lot or parcel of land on which is located the building or buildings they serve.

    Sewage works means sewage works as defined in subsection 1(1) of the Ontario Water Resources Act.

    Sewer lateral extension means the portion of a storm building sewer or sanitary building sewer that extends from the public sewer up to 1.5 m into the property.

    Shallow buried trench means an absorption trench that contains a chamber or leaching chamber.

    Shallow foundation means a foundation unit that derives its support from soil or rock located close to the lowest part of the building that it supports.

    Shelf and rack storage system means a self-contained structural system within a building, having one or more elevated platforms or walkway levels for personnel access that may also support conveyors and other material handling, storage and distribution equipment.

    Significant drinking water threat has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.

    Size means the nominal diameter by which a pipe, fitting, trap or other similar item is commercially designated.

    Smoke alarm means a combined smoke detector and audible alarm device designed to sound an alarm within the room or suite in which it is located upon the detection of smoke within that room or suite.

    Smoke detector means a fire detector designed to operate when the concentration of airborne combustion products exceeds a predetermined level.

    Soil means, except for the purposes of Part 8 of Division B, a portion of the earth’s crust that is fragmentary or such that individual particles of a dried sample may be readily separated by agitation in water, and includes boulders, cobbles, gravel, sand, silt, clay and organic matter.

    Soil pipe means a sanitary drainage pipe that carries the discharge of a sanitary unit, with or without the discharge from any other fixture.

    Soil stack means a vertical soil pipe that passes through one or more storeys and includes any offset that is part of the stack.

    Solid masonry means a single wythe or multi-wythe construction made of solid masonry units or semi-solid, cored, or hollow masonry units, the cells of which may or may not be filled with mortar or grout. In multi-wythe masonry construction, the space between the wythes consists of a mortar-filled collar joint or grout-filled space and the wythes may or may not be constructed of the same masonry materials.

    Solid masonry unit means a concrete block or brick unit, a clay brick unit, or a calcium silicate brick unit whose net solid area is at least 75% of its gross area. (See Note A-1.4.1.2.(1))

    Sound transmission class (STC) means a single number rating of the airborne sound attenuation of a building assembly separating two adjoining spaces, taking into account the direct sound transmission path. (See Note A-1.4.1.2.(1)) (See also Note A-9.11. of Division B)

    Source protection area has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.

    Source protection plan has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.

    Space heater means a space-heating appliance for heating the room or space within which it is located, without the use of ducts.

    Space-heating appliance means an appliance intended for the supplying of heat to a room or space directly, such as a >unit heater, or to rooms or spaces of a building through a heating system such as a central furnace or boiler.

    Sprinklered (as applying to a building or part thereof) means that the building or part thereof is equipped with a system of automatic sprinklers.

    Stack vent means a vent pipe that connects the top of a soil stack or waste stack to a header or open air and “stack vented” has a corresponding meaning.

    Stack venting means, when used with reference to fixtures, an arrangement such that the connections of the drainage piping from the stack vented fixtures to the stack provide venting to the fixture traps so that no additional vent pipe is required.

    Stage means a space that is designed primarily for theatrical performances with provision for quick change scenery and overhead lighting, including environmental control for a wide range of lighting and sound effects and that is traditionally, but not necessarily, separated from the audience by a proscenium wall and curtain opening.

    Starting platform means a rigid platform located entirely on a pool deck that consists of a top that, if projected horizontally over the water surface, would be less than 1,000 mm in vertical height above the surface and that is designed to be used by a swimmer to dive from at the start of a swimming race.

    Storage garage means a building or part thereof intended for the storage or parking of motor vehicles and containing no provision for the repair or servicing of such vehicles. (See Note A-1.4.1.2.(1))

    Storey means, except for the purposes of Part 7 of Division B, the portion of a building

    (a) that is situated between the top of any floor and the top of the floor next above it, or

    (b) that is situated between the top of the floor and the ceiling above the floor, if there is no floor above it.

    Storm building drain means a building drain that conducts storm water and is connected at its upstream end to a leader, sump or catch basin, and at its downstream end to a building sewer or a designated storm water disposal location.

    Storm building sewer means a building sewer that conveys storm sewage to a place of disposal and commences 1,000 mm from the building.

    Storm drainage pipe means all the connected piping that conveys storm sewage to a place of disposal and includes the storm building drain, storm building sewer, rain water leader, catch basin and area drain installed to collect water from the property and the piping that drains water from a swimming pool, other than a public pool, or from water cooled air-conditioning equipment, but does not include

    (a) a subsoil drainage pipe, or

    (b) a private sewage treatment and disposal facility designed for the treatment or retention of storm sewage prior to discharge to the natural environment.

    Storm drainage system means a drainage system that conveys storm sewage.

    Storm sewage means water that is discharged from a surface as a result of rainfall, snow melt or snowfall.

    Storm sewer means a sewer that conveys storm sewage.

    Stove means an appliance intended for cooking or space heating or both.

    Street means any highway, road, boulevard, square or other improved thoroughfare that is 9 m or more in width, that has been dedicated or deeded for public use and that is accessible to fire department vehicles and equipment.

    subsoil drainage pipe means a pipe that is installed underground to intercept and convey subsurface water, and includes foundation drain pipes.

    Subsurface investigation means the appraisal of the general subsurface conditions at a building site by analysis of information gained by such methods as geological surveys, in situ testing, sampling, visual inspection, laboratory testing of samples of the subsurface materials and groundwater observations and measurements.

    Suite means a single room or series of rooms of complementary use, operated under a single tenancy, and includes

    (a) dwelling units,

    (b) individual guest rooms in motels, hotels, boarding houses, rooming houses and dormitories, and

    (c) individual stores and individual or complementary rooms for business and personal services occupancies.

    (See Note A-1.4.1.2.(1))

    Supply duct means a duct for conveying air from a heating, ventilating or air-conditioning appliance to a space to be heated, ventilated or air-conditioned.

    Surface water means water on the surface of the ground.

    Tapered tread means a tread with non-parallel edges that increases or decreases its run uniformly over its width.

    Tarion Warranty Corporation means Tarion Warranty Corporation as designated under section 2 of the Ontario New Home Warranties Plan Act.

    Theatre means a place of public assembly intended for the production and viewing of the performing arts or the screening and viewing of motion pictures, and consisting of an auditorium with permanently fixed seats intended solely for a viewing audience.

    Trap means a fitting or device that is designed to hold a liquid seal that will prevent the passage of gas but will not materially affect the flow of a liquid.

    Trap arm means that portion of a fixture drain between the trap weir and the vent pipe fitting.

    Trap dip means the lowest part of the upper interior surface of a trap.

    Trap seal depth means the vertical distance between the trap dip and the trap weir.

    Trap standard means the trap for a fixture that is integral with the support for the fixture.

    Trap weir means the highest part of the lower interior surface of a trap.

    Treatment unit means a device that, when designed, installed and operated in accordance with its design specifications, provides a specific degree of sanitary sewage treatment to reduce the contaminant load from that of sanitary sewage to a given effluent quality.

    Tribunal means the Licence Appeal Tribunal established under the Licence Appeal Tribunal Act, 1999.

    Type A dispersal bed means a leaching bed that receives effluent from a Level IV treatment unit as described in Table 8.6.2.2. of Division B and that is comprised of a stone layer or leaching chambers installed over an unsaturated sand layer as described in Subsection 8.7.7. of Division B.

    Type B dispersal bed means a leaching bed comprised of a pressurized distribution system that uniformly distributes effluent from a Level IV treatment unit as described in Table 8.6.2.2. of Division B to the underlying soil, as defined in Part 8 of Division B, through a set of distribution pipes installed in a bed comprised of septic stone.

    Underpinning means the process of strengthening the foundation or lowering the level of a foundation of an existing building.

    Unit heater means a suspended space heater with an integral air-circulating fan.

    Unprotected opening means, when applied to an exposing building face.

    (a) a doorway, window or opening, other than one equipped with a closure having the required fire-protection rating, or

    (b) any part of a wall forming part of the exposing building face that has a fire-resistance rating less than required for the exposing building face.

    Unstable liquid means a liquid, including flammable liquids and combustible liquids, that is chemically reactive to the extent that it will vigorously react or decompose at or near normal temperature and pressure conditions or that is chemically unstable when subjected to impact.

    Vacuum breaker means back-siphonage preventer.

    Vapour barrier means the elements installed to control the diffusion of water vapour. (See Note A-1.4.1.2.(1))

    Vent connector (as applying to heating or cooling systems) means the part of a venting system that conducts the flue gases or vent gases from the flue collar of a gas appliance to the chimney or gas vent, and may include a draft control device.

    Vent pipe means a pipe that is part of a venting system.

    Vent stack means a vent pipe that is connected at its upper end to a header or is terminated in open air and that is used to limit pressure differential in a soil or waste stack.

    Venting system means an assembly of pipes and fittings that connects a drainage system with open air for circulation of air and the protection of trap seals in the drainage system.

    Vertical leg means the vertical portion of a fixture drain and includes the portion of a drain from the outlet of a water closet bowl to the point where the connecting piping changes to horizontal.

    Vertical service space means a shaft oriented essentially vertically that is provided in a building to facilitate the installation of building services including mechanical, electrical and plumbing installations and facilities such as elevators, refuse chutes and linen chutes.

    Vulnerable area has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.

    Walkway means a covered or roofed pedestrian thoroughfare used to connect 2 or more buildings.

    Waste pipe means a sanitary drainage pipe that carries the discharge from a fixture directly to a waste stack, soil stack, sanitary building drain, branch or sewage system .

    Waste stack means a vertical waste pipe that passes through one or more storeys and includes any offset that is part of the stack that conducts liquid waste from fixtures other than sanitary units.

    Water distribution system means an assembly of pipes, fittings, valves and appurtenances that conveys potable water to water supply outlets, fixtures, plumbing appliances and devices from the water service pipe or from a point of entry treatment unit located in the building.

    Water purveyor means the owner or operator of a drinking water system.

    Water service pipe means a pipe on the property that conveys potable water from a drinking water system or a private water supply to the inside of the building.

    Water system means a water service pipe, a private water supply, a water distribution system, a fire service main or any part of any of them.

    Wave action pool means a public pool equipped with a means for inducing wave motion in the water.

    Wet vent means a waste pipe that also serves as a vent pipe.

    Working capacity means the volume of liquid that a treatment unit or holding tank is capable of holding without overflowing while it is in its working position, but does not include the volume of liquid contained in a compartment in which a pump or siphon is installed.

    X-ray equipment includes x-ray imaging systems, processing equipment and equipment directly related to the production of images for diagnosis or directly related to irradiation with x-rays for therapy.

    X-ray machine means an electrically-powered device producing x-rays

    (a) for the irradiation of a human being or an animal for a therapeutic or diagnostic purpose, or

    (b) for industrial use.

    Yoke vent means a vent pipe that is connected at its lower end to a soil or waste stack and at its upper end to a vent stack or a branch vent that is connected to a vent stack.

    (2)Where a word or term that is defined in Sentence (1) is used, it shall be read as if it has the same meaning as in that Sentence, unless the context requires otherwise.

    Open OBC Div. A 1.4.1.2. in the code viewer
  • OBC Div. B 3.11.2.1. Pool Designations

    (1)Every public pool shall be designated as being either a Class A pool or a Class B pool in accordance with Sentence (2) or (3).

    (2)A Class A pool is a public pool to which the general public is admitted or that is

    (a)operated in conjunction with or as a part of a program of an educational, instructional, physical fitness or athletic institution or association, supported in whole or in part by public funds or public subscription, or

    (b)operated on the premises of a recreational camp, for use by campers and their visitors and camp personnel.

    (3)A Class B pool is a public pool that is

    (a)operated in conjunction with six or more dwelling units, suites, single family residences, or any combination of them for the use of occupants or residents and their visitors,

    (b)operated in conjunction with a mobile home park for the use of residents or occupants and their visitors,

    (c)operated on the premises of a hotel for the use of its guests and their visitors,

    (d)operated on the premises of a campground for the use of its tenants and their visitors,

    (e)operated in conjunction with a club for the use of its members and their visitors, or

    (f)operated in conjunction with an establishment or institution classified in Table 3.1.2.1. as

    (i)Group B, Division 1, major occupancy, or

    (ii)Group B, Division 2 or 3, major occupancy, for the use of residents or occupants and their visitors.

    Open OBC Div. B 3.11.2.1. in the code viewer
Show all 28 articles
  • OBC Div. B 3.11.3.1. Construction Requirements

    (1)Except as otherwise required in Subsections 3.11.4., 3.11.5., 3.11.6. and 3.11.7. or otherwise exempted in Sentences (2) and (3), Class A pools and Class B pools shall be designed and constructed to comply with Sentences (2) to (28) and Articles 3.11.3.2. and 3.11.3.3.

    (2)Where a Class B pool is constructed for use solely in conjunction with a club, child care facility, day camp or establishment or institution for the care of persons who are infirm, aged or in custodial care, the pool shall be exempt from the requirements of Clause (9)(a) and Sentences (13) and (14).

    (3)Where a Class B pool is constructed for use solely in conjunction with an establishment or institution for the treatment of persons with disabilities or persons who are ill, the pool shall be exempt from the requirements of Sentences (6) and (7), Clause (9)(a) and Sentences (13) and (14).

    (4)A public pool shall be constructed to have a water depth of not less than 750 mm except for

    (a)a modified pool,

    (b)a wave action pool,

    (c)a pool for therapeutic use,

    (d)a beach entry ramp, and

    (e)a pool described in Sentence 3.11.5.2.(1).

    (5)The beach entry ramp permitted in Clause (4)(d) shall be protected with permanent barriers between 900 mm to 1,200 mm along the pool deck to prevent entry into the pool until the minimum water pool depth is 750 mm.

    (6)Except for a modified pool, a wave action pool and a pool used exclusively for scuba diving, the slope of the bottom of any portion of a public pool shall not exceed

    (a)8% where the water depth is 1,350 mm or less,

    (b)33% where the water depth is more than 1,350 mm and less than 2,000 mm, and

    (c)50% where the water depth is 2,000 mm or more.

    (7)Except for a modified pool and wave action pool, where the slope of any portion of the bottom of a public pool is more than 8%, the walls of the pool shall be equipped with recessed fittings to which a safety line supported by buoys can be attached across the surface of the water and the recessed fittings shall be installed at a horizontal distance of at least 300 mm measured from the vertical projection of the top of the slope in the direction of the shallow end of the pool.

    (8)Except for a modified pool, wave action pool and a pool described in Sentence 3.11.5.2.(1), the side and end walls of a public pool shall be vertical from the top of the walls to within 150 mm of the bottom except at steps or recessed ladders or in water depths of 1,350 mm or more.

    (9)Except for a modified pool and wave action pool and except as provided in Sentence (11), a public pool shall be surrounded by a hard-surfaced pool deck that shall

    (a)except for a pool described in Sentence 3.11.5.2.(1), be not less than 1,800 mm wide with at least 1,100 mm of that width being a barrier-free path of travel described in Article 3.8.1.3., (See Note A-3.11.3.1.(9)(a))

    (b)in the case of an outdoor pool, be sloped away from the pool to waste drains or to adjacent lower ground at a slope of between 2% and 4%, and

    (c)in the case of an indoor pool, be impervious and sloped away from the pool to waste drains at a slope of between 1% and 4%.

    (10)Where a public pool is constructed with a ledge, the ledge shall

    (a)be placed only in parts of the pool where the water depth is 1,350 mm or more,

    (b)be not more than 200 mm wide,

    (c)be at least 1,000 mm below the water surface,

    (d)where located on the side of the pool, be gradually tapered towards the shallow end of the pool in such a manner as to prevent a harmful obstruction, and

    (e)have a band of contrasting colour along the entire juncture of the side and top of the ledge.

    (11)Notwithstanding Sentences (12) to (17), where a public pool is constructed on any level surface with walls rising above that surface and has a constant water depth not exceeding 1,100 mm and a water surface area not exceeding 100 m², the pool deck may be an elevated platform surrounding the pool if it has

    (a)an unobstructed width of not less than 900 mm,

    (b)a height of at least 75 mm above grade or pavement elevation,

    (c)6 mm wide openings for drainage, and

    (d)a non-slip surface that is capable of being kept clean and disinfected.

    (12)Except for a modified pool and wave action pool, where a pool deck projects over the water surface, the projection shall not exceed 50 mm.

    (13)Except for a modified pool and wave action pool, the pool deck shall be separated from any adjacent spectator area or gallery and from any spectator access to such area or gallery by a gate or other barrier.

    (14)Except for a modified pool and wave action pool, the perimeter of the pool deck shall be clearly delineated by a tactile attention indicator conforming to Article 3.8.3.18. and located where any area contiguous to the pool deck may be confused with the deck. (See Note A-3.11.3.1.(14))

    (15)Except for a modified pool and wave action pool, the perimeter of the pool deck shall be clearly delineated by painted lines or other means where any area contiguous to the pool deck may be confused with the deck.

    (16)Perimeter drainage shall be provided where necessary to prevent surface run-off from draining onto the pool deck.

    (17)Except for a modified pool, one or more hose bibbs shall be installed near the perimeter of the pool deck in locations convenient for flushing the pool deck.

    (18)Except for a modified pool and wave action pool, where access to the pool enclosure is over any surface that is not subject to regular cleaning and sanitizing, a foot spray to wash feet by means of a spray running freely to waste shall be provided at each such access.

    (19)Except for a modified pool and wave action pool, at least

    (a)one ladder or set of steps shall be provided in both the deep and shallow areas of a public pool for entry into and egress from the pool water, and

    (b)one barrier-free access shall be provided for entry into and egress from the water of a public pool as required by Article 3.11.3.3.

    (20)The pool deck, the submerged parts of a public pool, the walls or partitions adjacent to a pool deck and the pavement or floor adjacent to a pool deck shall have surfaces that permit thorough cleaning.

    (21)Except for markings for safety or competition purposes, submerged surfaces in public pools shall be finished white or light in colour.

    (22)Except in a modified pool, a black disc 150 mm in diameter on a white background shall be affixed to the bottom of a public pool within the area of its greatest depth.

    (23)A public pool shall be equipped with lockable doors or other barriers capable of preventing public access to the pool deck.

    (24)Except for a modified pool, wave action pool or a pool installed at a recreational camp, a Class A pool shall be provided with,

    (a)where the water surface area is greater than 150 m² but not greater than 230 m², at least one lifeguard control station, and

    (b)where the water surface area is greater than 230 m², at least two lifeguard control stations.

    (25)Except for a modified pool, every public pool shall display on the deck clearly marked figures, not less than 100 mm high, that set out

    (a)the water depths indicating the deep points, the breaks between gentle and steep bottom slopes and the shallow points.

    (b)the words shallow area at one or more appropriate locations, and

    (c)where the water depth exceeds 2,500 mm, the words DEEP AREA at one or more appropriate locations.

    (26)Except for a modified pool and a pool to which Sentence 3.11.5.2.(2) applies, every public pool having a maximum water depth of 2,500 mm or less shall display a warning notice posted in a location clearly visible to divers on which are printed in letters at least 150 mm high the words caution — avoid deep dives or shallow water — no diving.

    (27)Except where no space is provided between ladder treads and the pool wall, the space between the pool wall and submerged portions of any treads of a ladder for entry into and egress from the water shall be not more than 150 mm and not less than 75 mm.

    (28)If a set of steps is provided for entry into and egress from public pools in Sentence (19), the steps shall

    (a)be equipped with a handrail,

    (b)have a non-slip surface, and

    (c)have a band of contrasting colour along the entire juncture of the side and top of the edges

    Open OBC Div. B 3.11.3.1. in the code viewer
  • OBC Div. B 3.11.4.1. Diving Boards or Platforms

    (1)No diving board or diving platform shall be installed in a public pool unless the requirements of Sentences (5) to (17) are met but the requirements for a diving platform do not apply to a starting platform.

    (2)No diving board or diving platform shall be installed in a modified pool or a wave action pool.

    (3)Where a public pool is equipped with a diving board or a diving platform, the board or platform shall have a non-slip surface.

    (4)Where a diving board or a diving platform in a public pool is more than 600 mm above the water surface, the board or platform shall be equipped with one or more adjacent handrails.

    (5)Where a public pool is equipped with a diving board or a diving platform not more than 3 m in height above the water surface, the pool shall be designed and constructed in conformance with Sentences (6) to (15).

    (6)The depth of water in the area directly below a horizontal semi-circle in front of a diving board or diving platform having a radius of 3 m measured from any point on the front end of the board or platform shall not be less than

    (a)2,750 mm, where a board is 600 mm or less in height above the water surface,

    (b)3 m, where a board or platform is greater than 600 mm but not more than 1,000 mm in height above the water surface, and

    (c)3.65 m, where a board or platform is greater than 1,000 mm but not more than 3 m in height above the water surface.

    (7)Except as permitted in Sentence (8), the water depth in a public pool shall be at least 1,350 mm at the horizontal arc having a radius of 9 m measured from any point on the front end of the diving board or diving platform and intersecting the vertical projections of the walls of the pool.

    (8)Where a Class B pool is equipped with a diving board 600 mm or less in height above the water

    (a)the water depth shall be at least 1,350 mm at the horizontal arc having a radius of 7.5 m measured from any point on the front end of the diving board, and

    (b)a warning notice, on which is printed in letters at least 150 mm high, the words DANGER AVOID DEEP OR LONG DIVES, shall be posted in a location clearly visible to divers.

    (9)The slope of the bottom of a public pool having a diving board or diving platform shall not change by more than 17% where the water depth is less than the applicable depth set out in Sentence (6) and greater than the depth set out in Sentence (7) or (8), as applicable.

    (10)The horizontal distance between the vertical projection of the centre line of a diving board or diving platform and the vertical projection of the centre line of another board or platform shall be at least 2,750 mm.

    (11)The horizontal distance between the centre line of a diving board or diving platform and the vertical projection of the closest side or any ledge on the closest side of a public pool shall be at least

    (a)3 m, where a diving board or diving platform is 1,000 mm or less in height above the water surface, and

    (b)3.6 m, where a diving board or diving platform is greater than 1,000 mm in height above the water surface.

    (12)A diving board or a diving platform 600 mm or less in height above the water surface shall project over the water a horizontal distance of at least 900 mm from the vertical projection of a pool wall under it.

    (13)A diving board greater than 600 mm in height above the water surface shall project over the water a horizontal distance of at least 1,500 mm from the vertical projection of the pool wall under it.

    (14)A diving platform greater than 600 mm in height above the water surface shall project a horizontal distance of at least 1,200 mm from the vertical projection of the pool wall under it.

    (15)The space above a diving board or diving platform shall be unobstructed and shall consist of at least

    (a)a space having a width of 2,500 mm on each side of the centre line of the board or platform, a length equal to the sum of the horizontal distance the board or platform projects over the water plus 3 m, and a height of,

    (i)3.65 m above a diving board 3.65 m or less in length,

    (ii)5 m above a diving board greater than 3.65 m in length, or

    (iii)3 m above a diving platform, and

    (b)the space below the planes originating from the front and sides of the uppermost horizontal plane of the space determined under Clause (a) and sloping downwards at 30° from the horizontal.

    (16)A diving board or diving platform greater in height than 3 m above the water surface shall be equipped with a gate, barrier or other device capable of preventing access to the diving board or diving platform.

    (17)Where a public pool is to be equipped with diving boards or diving platforms greater than 3 m in height above the water surface, the design of the diving boards or diving platforms and the corresponding water depths and clearances shall be in accordance with FINA, "Rules and Regulations FINA Facilities Rules 2021-2025 FR3 Diving Facilities."

    Open OBC Div. B 3.11.4.1. in the code viewer
  • OBC Div. B 3.11.8.1. Recirculation Systems

    (1)Every public pool shall be equipped with a recirculation system.

    (2)For the purposes of this Subsection, the water in a public pool and its recirculation system is deemed not to be potable water.

    (3)The water in a public pool and its recirculation system shall be separated from the potable water supply and from the sewer or drainage system into which it drains by air gaps or other devices that prevent

    (a)the water in the pool or its recirculation system from flowing back into the potable water supply, and

    (b)the water in the sewer or drainage system from flowing back into the pool or its recirculation system.

    (4)The recirculation system of a public pool shall be designed, constructed and equipped to comply with Sentences (5) to (20).

    (5)The recirculation system of a public pool shall be capable of filtering, disinfecting and passing through the pool each day a volume of water of at least

    (a)in the case of a Class A pool, other than a modified pool or a wave action pool, six times the total water volume of the pool.

    (b)in the case of a Class B pool, other than a wave action pool, four times the total water volume of the pool,

    (c)in the case of a modified pool, three times the total water volume of the pool, and

    (d)in the case of a wave action pool, six times the total water volume of the pool.

    (6)A recirculation system shall be equipped with a flow meter registering the rate of water flow.

    (7)All pools shall be provided with automatic make-up water devices and provided with water meters to register the volume of all make-up water added to a public pool or its recirculation system.

    (8)Equipment shall be installed to continuously disinfect the water in a public pool by means of

    (a)a chlorination or hypochlorination system provided with a chemical controller for regulating the dosage of chlorine and capable of providing not less than,

    (i)in the case of an outdoor pool, other than a wave action pool, 300 g of chlorine per day per 10,000 L of total pool capacity,

    (ii)in the case of an indoor pool, other than a wave action pool, 200 g of chlorine per day per 10,000 L of total pool capacity,

    (iii)in the case of an outdoor wave action pool, 1,200 g of chlorine per day per 10,000 L of total pool capacity, and

    (iv)in the case of an indoor wave action pool, 800 g of chlorine per day per 10,000 L of total pool capacity, or

    (b)a bromination system capable of maintaining in the pool water a total bromine residual of 3 mg/L.

    (9)Chlorination equipment for a public pool shall contain a mechanism whereby the chlorine feed shall automatically terminate whenever the recirculation system ceases to supply clean water to the pool.

    (10)All exposed potable water piping and chlorine piping within a public pool water treatment service room shall be colour coded by means of

    (a)painting the entire outer surface of the piping, or

    (b)coloured bands at least 25 mm in width that are spaced along the piping at intervals of not more than 1,200 mm.

    (11)The colour coding referred to in Sentence (10) shall be yellow for chlorine and green for potable water.

    (12)Except for a modified pool and wave action pool, a public pool shall be equipped with overflow gutters or surface skimmers connected to the recirculation system that are capable of removing surface film from the surface of the water and withdrawing each day and discharging to the waste drains up to 15% of the total volume of pool water.

    (13)A public pool shall be equipped with clean water inlets arranged in conjunction with surface skimmers or overflow gutters to provide uniform distribution and circulation of clean water.

    (14)Except as permitted in Sentence (19), all fittings at or below the water surface that allow water and/or air to be passed to or from the public pool shall

    (a)have a maximum opening of 7 mm in one direction, and

    (b)be securely held in place by corrosion resistance fastening that require a tool for removal and are galvanically compatible with the fittings and grilles or covers.

    (15)Except as provided in Sentence 3.11.6.1.(7) for a modified pool, all fittings below the water surface that provide suction or gravity flow in a public pool shall

    (a)be provided with a minimum of two suction or gravity outlets interconnected to a full size manifold, and

    (b)be separated by a clear distance of not less than 1,200 mm.

    (16)Except as provided in Sentence 3.11.6.1.(7) for a modified pool, water in all public pools shall be capable of being emptied through the pool drains in 12 hours or less.

    (17)Except as provided in Sentence 3.11.6.1.(7) for a modified pool, openings in suction or gravity fittings shall

    (a)be such that the flow of water does not exceed 0.45 m/s and the velocity is calculated assuming all possible sources of suction flow are present at one time, and

    (b)be such that every suction fitting located within 1,000 mm of the water surface, except for skimmers and gutter fittings, contain openings with a minimum aggregate area of 0.2 m².

    (18)Except for skimmers and gutters, all submerged suction and gravity fittings shall be clearly and permanently marked with a 50 mm wide band in a contrasting colour.

    (19)Fittings returning water and/or air to the pool tank that are located within 300 mm of the water surface are permitted to have openings with one dimension more than 7 mm but shall contain no openings more than 25 mm in diameter.

    (20)Submerged skimmer equalizer fittings and vacuum fittings are not permitted in public pools.

    Open OBC Div. B 3.11.8.1. in the code viewer
  • OBC Div. B 3.11.9.1. Dressing Rooms and Sanitary Facilities

    (1)Except as otherwise permitted in Sentences (2) and (3), every public pool shall be equipped with dressing rooms, locker rooms, shower heads, water closets, urinals, lavatories and drinking fountains that shall be designed, constructed and equipped to comply with Sentences (4) to (14).

    (2)Where a Class A pool is installed on the premises of a recreational camp, dressing rooms, locker rooms, shower heads, water closets, urinals, lavatories and drinking fountains are not required if

    (a)dressing, water closet and shower facilities are conveniently available for bathers elsewhere on the premises, and

    (b)foot sprays are provided in accordance with Sentence 3.11.3.1.(18).

    (3)Where a Class B pool is installed, dressing rooms, locker rooms, shower heads, lavatories, water closets, drinking fountains and urinals are not required if

    (a)dressing, water closet and shower facilities are conveniently available elsewhere on the premises for bathers when the pool is open for use, and

    (b)foot sprays are provided in accordance with Sentence 3.11.3.1.(18).

    (4)The minimum number of water closets, urinals and lavatories shall be determined from Article 3.7.4.3. and Table 3.7.4.3.-C for an occupant load based on

    (a)the formula in Sentence 3.1.17.3.(1) for all public pools, except a wave action pool, or

    (b)the formula in Sentence 3.1.17.3.(2) for a wave action pool.

    (5)A minimum of one shower head shall be provided for every 40 bathers.

    (6)Where dressing and locker rooms, water closets and urinals are provided in conjunction with a public pool, they shall be located in such a manner that bathers, after using them, shall pass through or by a shower area to reach the pool deck.

    (7)All shower heads shall be supplied with potable water at a pressure of at least 140 kPa.

    (8)The shower water system shall have one or more tempering devices capable of being adjusted to ensure that water supplied to shower heads does not exceed 40°C.

    (9)Floors in washrooms, shower areas and passageways used by bathers shall slope to waste drains at not less than 1% and shall be of hard surfaced materials that do not become slippery when wet.

    (10)Joints between floors and walls shall be coved in areas described in Sentence (9) and in dressing and locker rooms.

    (11)Hose bibbs shall be provided in safe locations convenient for flushing down the walls and floors in washrooms, shower areas and passageways used by bathers.

    (12)Partitions or walls shall be provided to ensure privacy of dressing rooms, washrooms and shower areas.

    (13)The bottom of interior partitions in dressing rooms and washrooms shall be between 250 mm and 350 mm above the floor.

    (14)Dressing and locker room floors shall have non-slip surfaces that permit convenient and thorough cleaning and disinfecting.

    Open OBC Div. B 3.11.9.1. in the code viewer
  • OBC Div. B 3.12.2.1. Construction Requirements

    (1)In addition to the requirements of this Subsection, public spas shall comply with the requirements of Sentences 3.11.3.1.(13) to (18), (20), (21) and (23) and Clause 3.11.3.1.(25)(a).

    (2)A public spa shall be constructed to have a water depth of not more than 1,200 mm.

    (3)The slope of the bottom of any portion of a public spa shall not exceed 8%.

    (4)A public spa shall be surrounded by a hard-surfaced pool deck that

    (a)shall have a minimum clear deck space of not less than 1.8 m at the main entrance point,

    (b)shall have a clear deck space of 900 mm on all sides, except as required by Clause (a) and permitted by Sentence (5),

    (c)shall be sloped away from the pool to waste drains or to adjacent lower ground at a slope of between 2% and 4%, in the case of an outdoor public spa, and

    (d)shall be impervious and sloped away from the pool to waste drains at a slope of between 1% and 4%, in the case of an indoor public spa.

    (5)One section of the hard-surfaced pool deck that does not exceed 25% of the perimeter of the public spa may have a minimum clear deck space of not more than 300 mm if

    (a)the public spa has an area less than 6 m² , and

    (b)the public spa has no interior dimension more than 2.5 m.

    (6)The maximum depth of water to a seat or bench in a public spa shall be 600 mm.

    (7)If a set of steps is provided for entry into and egress from the public spa water, the steps

    (a)shall be equipped with a handrail,

    (b)shall have a non-slip surface, and

    (c)shall have a band of contrasting colour along the entire juncture of the side and top of the edges.

    (8)Every public spa shall be provided with dressing rooms, water closets and shower facilities that are conveniently available on the premises.

    (9)Except where no space is provided between ladder treads and the spa wall, the space between the spa wall and submerged portions of any treads of a ladder for entry into and egress from the water shall be not more than 150 mm and not less than 75 mm.

    Open OBC Div. B 3.12.2.1. in the code viewer
  • OBC Div. B 3.12.4.1. Water Circulation Systems

    (1)In addition to the requirements of this Subsection, the water circulation system of a public spa shall comply with the requirements of Sentences 3.11.8.1.(2), (3), (6), (7), (9), (10), (11), (13) and (20).

    (2)A public spa shall be equipped with a water circulation system that is capable of filtering, disinfecting and passing the public spa water through the public spa with a turnover period of not more than

    (a)30 minutes for a public spa with a volume of water that exceeds 6 m²,

    (b)20 minutes for a public spa with a volume of water that exceeds 4 m² but does not exceed 6 m², or

    (c)15 minutes for a public spa with a volume of water that does not exceed 4 m².

    (3)If cartridge-type filters are used for a public spa, the filters shall be a surface-type that is designed for a maximum flow rate of 0.27 L/s/m² effective filter area.

    (4)Except as provided in Sentence (6), every circulation system in a public spa shall be served by a minimum of two suction or gravity outlets

    (a)that are interconnected to a full-size manifold, and

    (b)except as provided in Sentence (5), that are separated by a clear distance of not less than 900 mm.

    (5)If compliance with Clause (4)(b) is impracticable because of dimensional restrictions at the bottom of the public spa, the outlets may be located on two different planes of the public spa if

    (a)at least one of the outlets through which the public spa can be emptied to a full-size manifold is located on the bottom of the public spa, and

    (b)the bottom of all outlets, other than skimmers, are not more than 75 mm from the floor of the public spa.

    (6)A circulation system in a factory-built public spa may be served by a built-in suction or gravity outlet with multiple openings that are connected to a full-size manifold.

    (7)All fittings at or below the water surface that allow water or air or both to be passed to or from the public spa shall be securely held in place by corrosion resistant fastening that requires a tool for removal and is galvanically compatible with the fittings and grilles or covers.

    (8)Except as provided in Sentence (9), all suction or gravity fittings installed at or below the water line of a public spa shall

    (a)have a maximum opening of 7 mm in one direction, and

    (b)be designed so that the flow of water through the openings does not exceed 0.45 m/s.

    (9)Sentence (8) does not apply to suction and gravity outlets that are equipped with anti-entrapment covers that comply with the requirements of ASME A112.19.8, "Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs."

    (10)The calculation of water velocities for the purposes of Clause (8)(b) and Sentences (11) and (12) and the calculation of water flow rates for the purposes of Sentence (9) shall be based on the assumption that all possible sources of suction flow are present at the same time.

    (11)The water velocity in a suction pipe shall not exceed 1.8 m/s.

    (12)The water velocity in a pressure pipe shall not exceed

    (a)3.0 m/s for plastic piping, and

    (b)1.8 m/s for copper piping.

    (13)Every suction system that serves a public spa shall be equipped with a vacuum relief mechanism that shall include

    (a)a vacuum release system,

    (b)a vacuum limit system, or

    (c)other engineered systems that are designed, constructed and installed to conform to good engineering practice appropriate to the circumstances.

    (14)Equipment shall be installed to continuously disinfect the water in a public spa by means of a chlorination, hypochlorination or bromination system that is capable of regulating the dosage of chlorine or bromine.

    (15)If a two-speed pump is utilized for a public spa, the filter and heater shall be sized to accommodate the maximum pump output, without exceeding the manufacturer's design flow rate of the filter element or heater and without by-passing the filter element.

    (16)A public spa equipped with hydro-massage jet fittings shall be provided with a timing device

    (a)that controls the period of operation of the jet pump, and

    (b)that is placed in a location where the user must exit the public spa to reset the timer.

    (17)A public spa water heater shall be equipped with an upper limit cut-off device,

    (a)that is independent of the normal public spa water temperature thermostat, and

    (b)that limits the maximum water temperature of the public spa to 40°C.

    (18)A public spa shall be equipped with a water circulation system that is capable of both completely and partially draining and refilling the public spa water.

    Open OBC Div. B 3.12.4.1. in the code viewer
  • OBC Div. B 3.12.5.1. Lighting and Emergency Provisions

    (1)In addition to the requirements of this Subsection, public spas shall comply with the requirements of Sentences 3.11.10.1.(1) to (6).

    (2)An emergency telephone directly connected to an emergency service or to the local telephone utility shall be installed within 30 m of the public spa.

    (3)All pumps used in a public spa shall be capable of being deactivated by an emergency stop button that is

    (a)clearly labelled, and

    (b)located at a point that is

    (i)readily accessible to and within sight of persons using the public spa, and

    (ii)within 15 m of the public spa.

    (4)The emergency stop button required in Sentence (3) shall

    (a)be a switch separate from the public spa's timing device,

    (b)activate an audible and a visual signal when used, and

    (c)have an emergency sign conforming to Sentence 3.11.10.1.(14).

    (5)If a public spa and public pool are located in the same room or space, the emergency stop buttons required in Sentences (3) and 3.11.10.1.(12) shall deactivate all pumps serving the public spa and public pool.

    Open OBC Div. B 3.12.5.1. in the code viewer
  • OBC Div. B 3.11.10.1. Lighting and Emergency Provisions

    (1)Except as provided in Sentences (2) and (3), rooms and spaces used by the public in conjunction with a public pool shall be capable of illumination to levels in compliance with Subsection 3.2.7.

    (2)Dressing rooms, locker rooms, shower rooms, washrooms and passageways shall have an illumination level of at least 200 lx at floor level.

    (3)An indoor pool or an outdoor pool that is intended to be open for use after sundown shall be equipped with a lighting system

    (a)that will maintain at any point on the pool deck and on the pool water surface an illumination level of at least

    (i)200 lx in the case of an indoor pool, and

    (ii)100 lx in the case of an outdoor pool, and

    (b)that makes the underwater areas of the pool clearly visible from any point on the pool deck.

    (4)An outdoor pool that is intended to be open for use after sundown and an indoor pool shall be equipped with an independent emergency lighting system that automatically operates whenever the normal electrical power supply to a public pool lighting system fails.

    (5)The independent emergency lighting system required in Sentence (4) shall be capable of illuminating the pool deck, washroom, shower, locker areas, pool water surface and all means of egress to a level of at least 10 lx.

    (6)An emergency power supply for the emergency lighting system required in Sentence (4) shall comply with Sentences 3.2.7.4.(1) and 3.2.7.7.(1) and Article 3.2.7.5.

    (7)An emergency telephone directly connected to an emergency service or to the local telephone utility shall be installed adjacent to the pool deck of every Class A pool.

    (8)A telephone accessible for emergency use shall be installed for every Class B pool within 30 m of the pool.

    (9)Every wave action pool shall have a public address system that shall be clearly audible in all portions of the pool.

    (10)Every wave action pool shall have a communication system for the use of persons engaged in supervision or operation of the pool that shall be interconnected with each lifeguard control station, the first-aid room and the bather admission control centre.

    (11)The public address system and the communication system described in Sentences (9) and (10) shall be interconnected.

    (12)All recirculating pumps used in a public pool shall be capable of being deactivated by an emergency stop button clearly labelled and located at

    (a)a Class A pool beside the telephone that is required in Sentence (7), and

    (b)a Class B pool on the deck area.

    (13)The emergency stop button in Sentence (12) shall, when used, activate an audible and a visual signal located by the emergency stop.

    (14)An emergency sign containing the words in the event of an emergency push emergency stop button and use emergency phone, audible and visual signal will activate shall be in letters at least 25 mm high with a 5 mm stroke and posted above the emergency stop button.

    Open OBC Div. B 3.11.10.1. in the code viewer
  • OBC Div. B 3.14.1.1. Application

    (1)Except as provided in this Subsection, tents are exempt from complying with the requirements of this Division.

    Open OBC Div. B 3.14.1.1. in the code viewer
  • OBC Div. B 3.14.1.2. General

    (1)Except as provided in Sentence (2), the requirements of this Subsection shall apply to all tents.

    (2)Articles 3.14.1.3., 3.14.1.7. and 3.14.1.8. do not apply to tents that

    (a)do not exceed 225 m² in ground area,

    (b)do not exceed 225 m² in aggregate ground area and are closer than 3 m apart,

    (c)do not contain bleachers, and

    (d)are not enclosed with sidewalls.

    Open OBC Div. B 3.14.1.2. in the code viewer
  • OBC Div. B 3.14.1.4. Clearance to Other Structures

    (1)Tents shall not be erected closer than 3 m to the property line.

    (2)Except as provided in Sentences (3) to (6), tents shall not be erected closer than 3 m to other tents or structures on the same property.

    (3)A walkway between a building and a tent occupied by the public is permitted provided

    (a)the tent is not closer than 3 m from the building, and

    (b)the walkway conforms to Article 3.2.3.19.

    (4)Tents not occupied by the public need not be separated from one another, and are permitted to be erected less than 3 m from other structures on the same property, where such closer spacing does not create a hazard to the public.

    (5)Tents located on fair grounds or similar open spaces, need not be separated from one another provided such closer spacing does not create a hazard to the public.

    (6)Where a tent is to be constructed in proximity to existing above ground electrical conductors, the tent shall be constructed in accordance with Article 3.1.20.1.

    Open OBC Div. B 3.14.1.4. in the code viewer
  • OBC Div. B 3.14.2.2. General

    (1)Air-supported structures shall not be used for Groups B, C or Group F, Division 1 major occupancies or for classrooms.

    (2)Except where no fire separation is required between major occupancies, air-supported structures shall contain not more than one major occupancy.

    (3)Except as provided in Sentence (5), air-supported structures are exempt from complying with Articles 3.2.2.20. to 3.2.2.93., except for maximum building size.

    (4)Air-supported structures may be designed with interior walls, mezzanines, or similar construction.

    (5)Interior construction contained within air-supported structures must meet the construction requirements of Articles 3.2.2.20. to 3.2.2.93.

    Open OBC Div. B 3.14.2.2. in the code viewer
  • OBC Div. B 3.14.2.6. Emergency Air Supply

    (1)An air-supported structure designed for an assembly occupancy with an occupant load of more than 200 persons shall have either an automatic emergency engine-generator set capable of powering one blower continuously for 4 h, or a supplementary blower powered by an automatic internal combustion engine.

    Open OBC Div. B 3.14.2.6. in the code viewer
  • OBC Div. B 3.15.1.2. Exceptions

    (1)The following signs shall not be subject to the provisions of this Section

    (a)signs for regulating traffic or similar devices, legal notices or warnings at railroad crossings,

    (b)signs in display windows including writing, representation, painting or lettering directly on the surface of any window or door, or other signs not affixed to the building interior,

    (c)small signs displayed for the direction of the public including signs that identify rest rooms, freight entrances and such other similar directional signs,

    (d)signs painted directly on a building, and

    (e)incidental signs or other signs subject to municipal approval.

    Open OBC Div. B 3.15.1.2. in the code viewer
  • OBC Div. B 3.15.5.2. Clearance for Exterior Signs

    (1)An exterior sign shall not be located so as to overhang a sidewalk or other pedestrian walkway unless the vertical distance, measured from the bottom of the overhanging portion of the sign to the surface of the sidewalk, is at least 2,400 mm.

    (2)Except as provided in Sentence (3), a sign face shall not be located within 600 mm of the vehicular travelled portion of a private lane or roadway, or of a motor vehicle parking area, unless the minimum vertical distance between grade and the bottom of the overhanging sign face is at least 4.25 m.

    (3)Where the height of all vehicles using any private road or parking area is permanently restricted, the vertical distance in Sentence (2) may be reduced to the amount of the actual height restriction, for as long as the said height restriction is in existence on the premises.

    (4)A sign shall not be located in proximity to existing above ground electrical conductors, unless the sign meets the clearance requirements of Article 3.1.20.1.

    Open OBC Div. B 3.15.5.2. in the code viewer
  • OBC Div. B 3.15.4.1. Combustible Sign Faces

    (1)Plastic materials used in the construction of sign faces shall

    (a)have an average burning rate not greater than

    (i)65 mm/min in sheets 1.5 mm thick when tested in accordance with ASTM D635, "Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position", or

    (ii)140 mm/min when tested in accordance with ASTM D3801, "Standard Test Method for Measuring the Comparative Burning Characteristics of Solid Plastics in a Vertical Position," and

    (b)have a measurement of material thickness in accordance with Method B-Machinists' Micrometer Without Ratchet of ASTM D374 / D374 m, "Standard Test Methods for Thickness of Solid Electrical Insulation."

    (2)Except as provided in Sentence (3), where the exterior cladding of a wall is required to be noncombustible, a plastic sign face or a group of contiguous plastic sign faces may be placed over such cladding provided each such sign face or group of contiguous sign faces

    (a)does not exceed 30% of the wall area of the storey on which it is installed,

    (b)does not exceed 15 m² in area or 1,200 mm in height at each storey, and

    (c)when located above the first storey, is vertically separated from other plastic sign faces by 1,200 mm of noncombustible construction unless separated by a horizontal noncombustible projection such as a canopy, extending the full width of, and projecting at least 900 mm beyond the exterior sign face.

    (3)Where a plastic exterior sign is mounted as a face on a metal sign box that is at least 200 mm in depth, the requirements of Sentence (2) need not apply provided the sign box is mounted on a noncombustible exterior wall.

    (4)Notwithstanding the requirements of Sentence (5), the plastic portion of an interior sign placed over or forming part of an interior wall surface in corridors, covered or enclosed walkways at or above grade in buildings shall

    (a)not exceed 15% of the wall area in, or over which it may be installed,

    (b)be supported by a device that will not detrimentally affect the fire-resistance rating of the interior wall to which it is attached or of which it may form a part, and encase the edges of the plastic sign face in metal,

    (c)not be positioned or sized in such a manner that it is less than 600 mm from the vertical line separating two adjacent premises,

    (d)be placed so that there is at least 600 mm vertical separation of noncombustible material between the top of the plastic sign surface and the ceiling surface,

    (e)be permitted to have an increase of 100% in area required in Clause (a) and a decrease of 50% of the separation distances required in Clauses (c) and (d) if the area is sprinklered, and

    (f)have a flame-spreading rating not more than 250.

    (5)Signs in exits and underground walkways shall have a flame-spread rating not more than 25.

    Open OBC Div. B 3.15.4.1. in the code viewer
  • OBC Div. A 1.4.1.2.(1) Shelf and rack storage system

    Shelf and rack storage system means a self-contained structural system within a building, having one or more elevated platforms or walkway levels for personnel access that may also support conveyors and other material handling, storage and distribution equipment.

    Open OBC Div. A 1.4.1.2.(1) in the code viewer
  • OBC Div. B 3.16.1.2. General

    (1)A shelf and rack storage system shall not be designed for production, manufacturing, assembling, disassembling or ancillary administrative functions.

    (2)A shelf and rack storage system may be designed for the storage, accessing, retrieval, packing and distribution of commodities.

    (3)A high-hazard industrial occupancy shall not contain a shelf and rack storage system.

    (4)Except as required by Sentence 3.16.3.2.(3), a shelf and rack storage system shall not exceed 24 m in height.

    Open OBC Div. B 3.16.1.2. in the code viewer
  • OBC Div. B 3.16.1.6. Sprinkler System

    (1)An automatic sprinkler system conforming to this Article shall be installed in a floor area containing a shelf and rack storage system.

    (2)The automatic sprinkler system shall be designed, constructed, installed and tested in conformance with NFPA 13, "Standard for the Installation of Sprinkler Systems" or the appropriate NFPA sprinkler standard for the most severe hazard to which the storage system is exposed.

    (3)Sprinkler protection shall be provided under all platforms and walkways.

    (4)Except where the platforms or walkways are of open construction, any openings for egress stairs shall be protected by noncombustible draft stops not less than 450 mm below the floors above.

    (5)The automatic sprinkler system shall be electrically supervised to indicate a trouble signal on the building fire alarm system annunciator or where the building does not have a fire alarm system, to notify the person controlling the operation of the building for each of the situations listed in Sentence 3.2.4.9.(3).

    (6)The automatic sprinkler system shall be designed to notify the fire department that a waterflow switch has been activated.

    (7)The notification to the person controlling the building and the fire department referred to in Sentences (5) and (6) shall be provided in accordance with Sentence 3.2.4.7.(4).

    (8)A permanent sign shall be posted, at or near the sprinkler control valve, containing

    (a)the word notice in contrasting letters,

    (b)a description of the commodity class as defined in NFPA 13, "Standard for the Installation of Sprinkler Systems," and

    (c)the sprinkler design criteria used for the shelf and rack storage system.

    Open OBC Div. B 3.16.1.6. in the code viewer
  • OBC Div. B 3.16.1.7. Exits and Means of Egress

    (1)Except as permitted in Sentences (2) and (3), every walkway or platform level shall be provided with no fewer than two exits conforming to Section 3.4.

    (2)An access to exit from an elevated platform level may be provided by means of open unenclosed stairs serving

    (a)not more than four platform levels, the highest of which shall be not more than 12 m above the main floor, where the shelf and rack storage system is intended for the storage of Class I, II, III and IV commodities, as defined in NFPA 13, "Standard for the Installation of Sprinkler Systems," and

    (b)not more than two platform levels, where the shelf and rack storage system is intended for the storage of Group A, B and C plastics and rubber tires, as defined in NFPA 13, "Standard for the Installation of Sprinkler Systems."

    (3)Any single platform or walkway in a shelf and rack storage system may be served by a single unenclosed stair leading to the platform or walkway level immediately below provided

    (a)the platform or walkway does not exceed 200 m² in area,

    (b)the travel distance on the platform or walkway to the level below, including the travel distance along the single unenclosed egress stair, does not exceed 25 m, and

    (c)the platform or walkway below is provided with two separate egress stairs or exits.

    (4)The maximum travel distance on an elevated platform to the ground floor level, including the travel distance along unenclosed stairs, shall not exceed 45 m.

    (5)The maximum travel distance on an elevated platform to an exit serving that platform shall not exceed 45 m.

    (6)Except as permitted in Sentence (7), the maximum travel distance from the bottom of an unenclosed stair to an exit along a main aisle on the ground floor level shall not exceed 45 m.

    (7)Where the travel distance in Sentence (6) exceeds 45 m

    (a)an egress system serving the shelf and rack storage system shall be designed on the basis of a time-based egress analysis using the following criteria:

    (i)occupant egress speed of 1 m/sec shall be used for horizontal egress routes within the shelf and rack storage system,

    (ii)occupant egress speed of 0.6 m/sec shall be used for vertical egress routes within the shelf and rack storage system, measured on the diagonal along the nosing of the stairs,

    (iii)occupant egress speed of 1.3 m/sec shall be used for horizontal egress routes along a main aisle on the ground floor level,

    (iv)each lift-gate shall be accorded an egress time of 10 seconds,

    (v)each at-level conveyor cross-over shall be accorded a time of 5 seconds, and

    (vi)a safety factor of 1.5 shall be used in calculating the total egress time,

    (b)the total egress time shall be calculated using the following formula:

    Total Egress Time = ( H_p + V_p / 0.6 + H_m / 1.3 + 10N_lg + 5N_lc ) · 1.5 (in seconds)

    where:

    H_p = horizontal travel distance on the shelf and rack storage system, in metres,

    V_p = vertical travel distance on the shelf and rack storage system, in metres,

    H_m = horizontal travel distance on the main floor, in metres,

    N_lg = number of lift gates in the means of egress,

    N_lc = number of at-level cross overs in the means of egress,

    (c)the total egress time from any point in the shelf and rack storage system shall be a maximum of 4 minutes,

    (d)a fire alarm and detection system conforming to Subsection 3.2.4. shall be installed in the building,

    (e)smoke detectors shall be provided under all solid decking and walkways,

    (f)clearly identified and easily accessible pull stations shall be provided at egress stairs, conveyor cross-overs or lift-gates located along egress paths, and

    (g)the occupant load on each level of the shelf and rack storage system shall not exceed 10 persons per egress stair. (See Note A-3.16.1.7.(7))

    (8)A dead-end aisle shall not exceed 9 m where the platform or walkway is provided with two or more egress facilities.

    (9)An aisle serving a shelf and rack storage system shall have a clear-aisle width of not less than 760 mm.

    (10)Conveyors, trolleys, tracks or any other similar mode of product transportation within the aisle or walkway shall not reduce the clear-aisle width required in Sentence (9).

    (11)Where exits are provided to comply with Sentence 3.4.2.5.(2), main aisles serving the shelf and rack storage system on the ground floor, leading from egress stairs directly to an exit, shall be clearly demarcated and have a minimum unobstructed, clear-aisle width of 2.4 m.

    (12)Where a lift-gate is incorporated along an egress route,

    (a)a maximum of two lift-gates may be within a single egress route,

    (b)each lift-gate shall be equipped with a positive lock when open, and

    (c)it shall be designed to automatically stop the conveyor belt that it serves when the lift-gate is open.

    (13)Where an at-level conveyor cross-over is incorporated along an egress route,

    (a)not more than two at-level conveyor cross-overs shall be within a single egress route,

    (b)handrails spaced not more than 1 m apart and parallel to the direction of egress shall be provided on both sides of the at-level cross-over,

    (c)flat, metal inserts shall be placed between each roller over the required egress width at each at-level conveyor cross-over to provide a walking surface,

    (d)at least two inserts not less than 100 mm wide shall be arranged symmetrically between the handrails serving the at-level cross-over,

    (e)inserts shall be sized to support loads specified in Part 4,

    (f)a clearly identified and easily accessible switch that will stop the conveyor shall be located at each at-level cross-over, and

    (g)stairs approaching at-level conveyor cross-overs shall be marked to indicate that they are readily identifiable as part of the egress route.

    Open OBC Div. B 3.16.1.7. in the code viewer