Values this chapter turns on
- max annual radon level in designated areas
- 200 Bq/m³
- max annual radon level in designated areas
- floor area per person for low human occupancy
- 40 m²
- floor area per person for low human occupancy
- roof slope treated as a wall under 9.10.
- 60°
- roof slope treated as a wall under 9.10.
- minimum thickness of soil under Part 8
- 100 mm
- minimum thickness of soil under Part 8
The CBO exam is mostly legal, but the syllabus picks a handful of technical scope items that a chief building official must apply when deciding which rules govern a project. They are short provisions, which makes them ideal lookup questions: farm building classification, radon areas, flood plains, window standards, the special Part 7 and Part 8 definitions, and where Part 9 applies. Read the article in the Compendium; this chapter paraphrases.
Referenced documents and organizations
Division A Section 1.5 controls standards that the code incorporates by reference.
- Referenced documents (and documents they reference) apply only so far as they relate to buildings and to the objectives and functional statements of the acceptable solutions where they are cited (OBC Div. A 1.5.1.1.OBC Div. A 1.5.1.1. Application of Referenced Documents(1) The provisions of documents referenced in this Code, and of any documents referenced within those documents, apply only to the extent that they relate to (a) buildings, and (b) the objectives and functional statements attributed to the applicable acceptable solutions in Division B where the documents are…). A clause in a standard about factory worker procedures, for example, is not enforceable by the CBO.
- If the code and a referenced document conflict, the code governs (OBC Div. A 1.5.1.2.OBC Div. A 1.5.1.2. Conflicting Requirements(1) In case of conflict between the provisions of this Code and those of a referenced document, the provisions of this Code shall govern.).
- The edition that applies is the one listed in Division B Subsection 1.3.1. (OBC Div. A 1.5.1.3.OBC Div. A 1.5.1.3. Applicable Editions(1) Where documents are referenced in this Code, they shall be the editions designated in Subsection 1.3.1. of Division B.).
- Abbreviations of organization names are explained in Division B 1.3.2.1. (OBC Div. A 1.5.2.1.OBC Div. A 1.5.2.1. Abbreviations of Proper Names(1) The abbreviations of proper names in this Code shall have the meanings assigned to them in Article 1.3.2.1. of Division B.).
Farm buildings: scope, application and classification
Part 2 of Division B deals with the fire, structural, heating, ventilating and air-conditioning performance of farm buildings, and with farm processes that carry explosion or high flammability risks (OBC Div. B 2.1.1.1.OBC Div. B 2.1.1.1. Scope(1) This Part is concerned with the fire, structural, heating, ventilating and air-conditioning performance of farm buildings, as well as processes and operations carried out therein that involve a risk of explosion, high flammability or related conditions that create a hazard to life safety. (See Note A-2.1.1.1.(1))). A "farm building" is a building or part that contains an agricultural occupancy (OBC Div. A 1.4.1.2.OBC Div. A 1.4.1.2.(1) Farm buildingFarm building means a building or part thereof that contains an agricultural occupancy. (See Note A-1.4.1.2.(1))).
Classification depends on occupant load (OBC Div. B 2.1.2.2.OBC Div. B 2.1.2.2. Classification of Buildings Containing agricultural occupancies(1) Buildings or parts of buildings containing an agricultural occupancy that has an occupant load of not more than one person per 40 m² shall be classified according to their major occupancy as belonging to Group G, Division 1, 2, 3 or 4. (2) Buildings or parts of buildings containing an agricultural occupancy that…): an agricultural occupancy with no more than one person per 40 m² is classified in Group G; if more crowded, it is classified under the ordinary groups in Table 3.1.2.1. "Low human occupancy" uses the same one person per 40 m² test (OBC Div. A 1.4.1.2.OBC Div. A 1.4.1.2.(1) Low human occupancyLow human occupancy means, when applied to a farm building, an occupancy in which the occupant load is not more than one person per 40 m² of floor area during normal use.).
Group G has four divisions in Table 2.1.4.1.: G-1 covers high-hazard farm uses, G-3 greenhouses, G-4 farm buildings with no human occupants, and G-2 the remaining agricultural uses.
Application (OBC Div. B 2.1.2.1.OBC Div. B 2.1.2.1. Application(1) Except as provided in Sentences (2) and (3), this Part applies to all farm buildings (a) that are (i) more than 600 m² in building area or more than 3 storeys in building height used for major occupancies classified as Group G, Division 1, 2 or 3 agricultural occupancies, or (ii) used for major occupancies…): Part 2 applies in full to G-1, G-2 and G-3 farm buildings over 600 m² in building area or over 3 storeys, and to G-4 buildings. Smaller G-1 to G-3 farm buildings (3 storeys or less, 600 m² or less) follow the National Farm Building Code of Canada with Ontario modifications, using SB-1 climatic values, and a low human occupancy farm building within those limits may use SB-11 for structure (OBC Div. B 2.1.2.3.OBC Div. B 2.1.2.3. Small Farm Buildings(1) Except as provided in Sentences (2) to (6), farm buildings not more than 3 storeys in building height and not more than 600 m² in building area used for major occupancies classified as Group G, Division 1, 2, or 3 agricultural occupancies shall conform to the requirements in the CCBFC NRCC 38732 National Farm…). A Group G farm building is assigned its division using Table 2.1.4.1. (OBC Div. B 2.1.4.1.OBC Div. B Table 2.1.4.1. Classification of Agricultural major occupanciesTable 2.1.4.1. Classification of Agricultural major occupancies Forming Part of Sentence 2.1.4.1.(1) Group | Division | Description of Agricultural Occupancies G | 1 | High-hazard agricultural occupancies G | 2 | Agricultural occupancies not elsewhere classified in Group G G | 3 | Greenhouse agricultural occupancies G…).
Radon and building in flood plains
In three designated areas, buildings must be designed and built so annual average radon 222 stays at or below 200 Bq/m³ of air, and short-lived radon daughters at or below 0.02 working levels (OBC Div. B 9.1.1.7.OBC Div. B 9.1.1.7. Radon(1) In addition to all other requirements, a building in the following designated areas shall be designed and constructed so that the annual average concentration of radon 222 does not exceed 200 Bq/m³ of air and the annual average concentration of the short lived daughters of radon 222 does not exceed 0.02 working…; the Part 3 version is 3.1.1.5.OBC Div. B 3.1.1.5. Radon(1) In addition to all other requirements, a building in the following designated areas shall be designed and constructed so that the annual average concentration of radon 222 does not exceed 200 Bq/m² of air and the annual average concentration of the short lived daughters of radon 222 does not exceed 0.02 working…). The areas:
- City of Elliot Lake (Algoma),
- Township of Faraday (Hastings),
- geographic Township of Hyman (Sudbury).
Buildings on flood plains must be designed to good engineering practice to resist vertical and horizontal hydrostatic pressures, and must include floodproofing that preserves exits and means of egress during floods (OBC Div. B 3.1.1.6.OBC Div. B 3.1.1.6. Building in Flood Plains(1) Buildings constructed on flood plains shall (a) be designed and constructed in accordance with good engineering practice to withstand anticipated vertical and horizontal hydrostatic pressures acting on the structure, and (b) incorporate floodproofing measures that will preserve the integrity of exits and means of…, 9.1.1.8.OBC Div. B 9.1.1.8. Building in Flood Plains(1) Buildings constructed on flood plains shall, (a) be designed and constructed in accordance with good engineering practice to withstand anticipated vertical and horizontal hydrostatic pressures acting on the structure, and (b) incorporate floodproofing measures that will preserve the integrity of exits and means of…).
Applicable standards for environmental separation
Part 5 requires materials in environmental separators or exterior assemblies to meet the standards in Table 5.9.1.1. A useful exception: flame-spread requirements inside thermal insulation standards apply only as Part 3 requires (OBC Div. B 5.9.1.1.OBC Div. B 5.9.1.1. Compliance with Applicable Standards(1) Except as provided in Sentence (2) and elsewhere in this Part, materials and components, and their installation, shall conform to the requirements of the applicable standards in Table 5.9.1.1. where those materials or components are (a) incorporated into environmental separators or assemblies exposed to the…).
Windows, doors and skylights must meet the North American Fenestration Standard (AAMA/WDMA/CSA 101/I.S.2/A440) and the Canadian Supplement CSA A440S1. Performance grades are chosen from the Canadian Supplement to suit the conditions and location, then verified by testing to the Harmonized Standard (OBC Div. B 5.9.2.2.OBC Div. B 5.9.2.2. Applicable Standards(1) Windows, doors and skylights shall conform to the requirements in (a) AAMA/WDMA/CSA 101/I.S.2/A440, "North American Fenestration Standard/Specification for windows, doors, and skylights" (Harmonized Standard), and (b) CSA A440S1, "Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, North American Fenestration…).
Plumbing and sewage system definitions
Parts 7 and 8 each give one local definition that overrides the general one.
- Part 7 "storey": the interval between two floor levels, counting mezzanines that contain plumbing fixtures, or between a floor and the roof (OBC Div. B 7.1.1A.1.OBC Div. B 7.1.1A.1. Definitions(1) Except as provided in Sentence (2), words that appear in italics are defined in Article 1.4.1.2. of Division A and in the Building Code Act, 1992. (2) In this Part, Storey means the interval between two successive floor levels including mezzanine floors that contain plumbing fixtures or between a floor level and…). A mezzanine with a washroom therefore counts as a storey for plumbing purposes.
- Part 8 "soil": naturally occurring, unconsolidated mineral or organic material at the surface, at least 100 mm thick and able to support plant growth; it excludes displaced material such as gravel dumps and mine spoils (OBC Div. B 8.1.1.2.OBC Div. B 8.1.1.2. Definitions(1) Except as provided in Sentence (2), words that appear in italics are defined in Article 1.4.1.2. of Division A and in the Building Code Act, 1992. (2) In this Part, Soil means in-situ, naturally occurring, unconsolidated mineral or organic material, at the earth's surface that is at least 100 mm thick and capable…).
Part 9 application, sloped roofs and residential suites in industrial buildings
Part 9 applies as Division A 1.3.3.3. describes (OBC Div. B 9.1.1.1.OBC Div. B 9.1.1.1. Application(1) The application of this Part shall be as described in Subsection 1.3.3. of Division A.): buildings of 3 storeys or less and 600 m² or less in building area used for Group C (other than retirement homes), D, E, or F-2 and F-3 occupancies (OBC Div. A 1.3.3.3.OBC Div. A 1.3.3.3. Application of Part 9(1) Subject to Article 1.3.3.3B., Part 9 of Division B applies to all buildings described in Article 1.1.1.1. of 3 storeys or less in building height, having a building area not exceeding 600 m², and used for major occupancies classified as (a) reserved (b) Group C, residential occupancies other than buildings used…). Section 9.1. then sends some special buildings to Part 3: signs to 3.15., self-service storage to 3.10., tents and air-supported structures to 3.14., food premises to 3.7.6., public pools and public spas to 3.11. and 3.12., shelf and rack storage to 3.16. A manufactured building is deemed to comply if built to CSA Z240.2.1 (sections not wider than 4.88 m) or CSA A277, but site installation and components built off the factory floor still follow the code (OBC Div. B 9.1.1.9.OBC Div. B 9.1.1.9. Site Assembled and Factory-Built Buildings(1) Except as provided in Sentence (2) and in Sentence 12.2.1.2.(2), a manufactured building is deemed to comply with this Code if it is designed and constructed in compliance with, (a) CSA Z240.2.1, "Structural requirements for manufactured homes," if the building is constructed in sections not wider than 4.88 m, or…).
For fire protection in Section 9.10., a roof sloped 60° or more from horizontal and next to an occupied room or space is treated as a wall (OBC Div. B 9.10.1.1.OBC Div. B 9.10.1.1. Sloped Roofs(1) For the purposes of this Section, roofs with slopes of 60° or more to the horizontal and that are adjacent to a room or space intended for occupancy shall be considered as a wall.). A Group F-2 building may contain only one residential suite, except where the F-2 occupancy is directly related to live/work units (OBC Div. B 9.10.9.14.OBC Div. B 9.10.9.14. Residential Suites in Industrial Buildings(1) Except as provided in Sentence (2), not more than one suite of residential occupancy shall be contained within a building classified as a Group F, Division 2 major occupancy. (2) Except where a Group F Division 2 major occupancy is directly related to live/work units, not more than one suite of residential…).
| Quick numbers | Value |
|---|---|
| Farm building Part 2 full application | over 600 m² or over 3 storeys (G-1 to G-3) |
| Low human occupancy | 1 person per 40 m² or less |
| Radon limit | 200 Bq/m³, 0.02 working levels |
| Part 8 soil depth | at least 100 mm |
| Sloped roof treated as wall | 60° or more |
| Part 9 size | 3 storeys, 600 m² |
Worked scenarios
New barn. A 900 m² single-storey dairy barn with low occupant load is a G-2 farm building over 600 m², so Part 2 of Division B applies in full.
Mansard storey. An attic storey has a 70° roof face adjacent to bedrooms. For Section 9.10., that face is a wall, so spatial separation and fire rules for walls apply.
Second apartment in a workshop. A Part 9 machine shop (F-2) already has a caretaker suite. A second suite is not permitted unless the occupancy relates to live/work units.
Common traps
- The code beats a referenced standard in a conflict, never the reverse.
- Farm building "low human occupancy" is per 40 m², not per 10 m².
- Retirement homes are not Part 9 even if small.
- The Part 7 storey definition includes plumbing mezzanines only.
Chapter review
Chapter at a glance
One line per section: the idea to carry into the exam. Then the answers that most often catch candidates out.
- Referenced documents and organizations
Division A Section 1.5 controls standards that the code incorporates by reference.
- Farm buildings: scope, application and classification
Part 2 of Division B deals with the fire, structural, heating, ventilating and air-conditioning performance of farm buildings, and with farm processes that carry explosion or high…
- Radon and building in flood plains
In three designated areas, buildings must be designed and built so annual average radon 222 stays at or below 200 Bq/m³ of air, and short-lived radon daughters at or below 0.02…
- Applicable standards for environmental separation
Part 5 requires materials in environmental separators or exterior assemblies to meet the standards in Table 5.9.1.1. A useful exception: flame-spread requirements inside thermal…
- Plumbing and sewage system definitions
Parts 7 and 8 each give one local definition that overrides the general one.
- Part 9 application, sloped roofs and residential suites in industrial buildings
Part 9 applies as Division A 1.3.3.3. describes: buildings of 3 storeys or less and 600 m² or less in building area used for Group C (other than retirement homes), D, E, or F-2…
Usual exam traps
- The code beats a referenced standard in a conflict, never the reverse.
- Farm building "low human occupancy" is per 40 m², not per 10 m².
- Retirement homes are not Part 9 even if small.
- The Part 7 storey definition includes plumbing mezzanines only.
Practice this chapter
Questions on Code structure and scope items from Divisions A and B, in the exam format, every answer explained and cited to its article. Sign in to start; a free account gets the free questions.
Code cited in this chapter
Based on the official 2024 Building Code Compendium on ontario.ca.
© King's Printer for Ontario, 2024. Reproduced with permission.
OBC Div. A 1.5.1.1. Application of Referenced Documents
Open OBC Div. A 1.5.1.1. in the code viewer(1)The provisions of documents referenced in this Code, and of any documents referenced within those documents, apply only to the extent that they relate to
(a)buildings, and
(b)the objectives and functional statements attributed to the applicable acceptable solutions in Division B where the documents are referenced. (See Note A-1.5.1.1.(1))
OBC Div. A 1.5.1.2. Conflicting Requirements
Open OBC Div. A 1.5.1.2. in the code viewer(1)In case of conflict between the provisions of this Code and those of a referenced document, the provisions of this Code shall govern.
OBC Div. A 1.5.1.3. Applicable Editions
Open OBC Div. A 1.5.1.3. in the code viewer(1)Where documents are referenced in this Code, they shall be the editions designated in Subsection 1.3.1. of Division B.
OBC Div. A 1.5.2.1. Abbreviations of Proper Names
Open OBC Div. A 1.5.2.1. in the code viewer(1)The abbreviations of proper names in this Code shall have the meanings assigned to them in Article 1.3.2.1. of Division B.
OBC Div. B 2.1.1.1. Scope
Open OBC Div. B 2.1.1.1. in the code viewer(1)This Part is concerned with the fire, structural, heating, ventilating and air-conditioning performance of farm buildings, as well as processes and operations carried out therein that involve a risk of explosion, high flammability or related conditions that create a hazard to life safety. (See Note A-2.1.1.1.(1))
OBC Div. A 1.4.1.2.(1) Farm building
Open OBC Div. A 1.4.1.2.(1) in the code viewerFarm building means a building or part thereof that contains an agricultural occupancy. (See Note A-1.4.1.2.(1))
OBC Div. B 2.1.2.2. Classification of Buildings Containing agricultural occupancies
Open OBC Div. B 2.1.2.2. in the code viewer(1)Buildings or parts of buildings containing an agricultural occupancy that has an occupant load of not more than one person per 40 m² shall be classified according to their major occupancy as belonging to Group G, Division 1, 2, 3 or 4.
(2)Buildings or parts of buildings containing an agricultural occupancy that has an occupant load of more than one person per 40 m² shall be classified according to their major occupancy as belonging to one of the Groups and Divisions listed in Table 3.1.2.1. of Division B.
(3)For the purposes of Sentences (1) and (2), the occupant load shall be determined based on the floor area or the part of the floor area that contains the agricultural occupancy.
(4)A building intended for use by more than one major occupancy shall be classified according to all the major occupancies for which it is used or intended to be used.
OBC Div. A 1.4.1.2.(1) Low human occupancy
Open OBC Div. A 1.4.1.2.(1) in the code viewerLow human occupancy means, when applied to a farm building, an occupancy in which the occupant load is not more than one person per 40 m² of floor area during normal use.
Show all 24 articles
OBC Div. B 2.1.2.1. Application
Open OBC Div. B 2.1.2.1. in the code viewer(1)Except as provided in Sentences (2) and (3), this Part applies to all farm buildings
(a)that are
(i)more than 600 m² in building area or more than 3 storeys in building height used for major occupancies classified as Group G, Division 1, 2 or 3 agricultural occupancies, or
(ii)used for major occupancies classified as Group G, Division 4, with no human occupantsagricultural occupancies, and
(b)described in Sentence 2.1.2.2.(1).
(2)Subsections 2.2.6. and 2.2.7. do not apply to Group G, Division 4 major occupancies.
(3)farm buildings not described in Sentence (1) shall conform to the requirements of Article 2.1.2.3.
OBC Div. B 2.1.2.3. Small Farm Buildings
Open OBC Div. B 2.1.2.3. in the code viewer(1)Except as provided in Sentences (2) to (6), farm buildings not more than 3 storeys in building height and not more than 600 m² in building area used for major occupancies classified as Group G, Division 1, 2, or 3 agricultural occupancies shall conform to the requirements in the CCBFC NRCC 38732 National Farm Building Code of Canada.
(2)Articles 1.1.1.2. and 3.1.8.1. and Subsections 3.1.4. and 4.1.4. in the CCBFC NRCC 38732 National Farm Building Code of Canada do not apply to farm buildings.
(3)Except as provided in Sentence (4), in the CCBFC NRCC 38732 National Farm Building Code of Canada, references in Articles 1.1.1.3., 2.2.2.1., 2.2.2.2., 2.3.1.1., 2.3.2.1., 3.1.1.1., 3.1.1.2., 3.1.2.1. and 3.1.6.1. to the CCBFC NRCC 38726 National Building Code of Canada, are deemed to be references to Ontario Regulation 403/97 (Building Code), as it read on December 30, 2006.
(4)The climatic values required for the design of farm buildings shall be in conformance with the climatic values provided in MMAH Supplementary Standard SB-1, Climatic and Seismic Data.
(5)A farm building of low human occupancy having a building area not exceeding 600 m² and not more than three storeys in building height is deemed to comply with the structural requirements of CCBFC NRCC 38732 National Building Code of Canada, if it is designed and constructed in conformance with MMAH Supplementary Standard SB-11, Construction of Farm Buildings.
(6)Where a floor area or portion of a floor area within a farm building is intended to contain a hazardous extraction operation involving cannabis, the floor area or portion of the floor area shall conform to the requirements of Article 2.2.8.9.
OBC Div. B Table 2.1.4.1. Classification of Agricultural major occupancies
Open OBC Div. B Table 2.1.4.1. in the code viewerTable 2.1.4.1. Classification of Agricultural major occupancies Forming Part of Sentence 2.1.4.1.(1) Group | Division | Description of Agricultural Occupancies G | 1 | High-hazard agricultural occupancies G | 2 | Agricultural occupancies not elsewhere classified in Group G G | 3 | Greenhouse agricultural occupancies G | 4 | Agricultural occupancies with no human occupants
OBC Div. B 9.1.1.7. Radon
Open OBC Div. B 9.1.1.7. in the code viewer(1)In addition to all other requirements, a building in the following designated areas shall be designed and constructed so that the annual average concentration of radon 222 does not exceed 200 Bq/m³ of air and the annual average concentration of the short lived daughters of radon 222 does not exceed 0.02 working levels inside the building for,
(a)the City of Elliot Lake in the Territorial District of Algoma,
(b)the Township of Faraday in the County of Hastings, and
(c)the geographic Township of Hyman in the Territorial District of Sudbury.
OBC Div. B 3.1.1.5. Radon
Open OBC Div. B 3.1.1.5. in the code viewer(1)In addition to all other requirements, a building in the following designated areas shall be designed and constructed so that the annual average concentration of radon 222 does not exceed 200 Bq/m² of air and the annual average concentration of the short lived daughters of radon 222 does not exceed 0.02 working levels inside the building:
(a)the City of Elliot Lake in the Territorial District of Algoma,
(b)the Township of Faraday in the County of Hastings, and
(c)the geographic Township of Hyman in the Territorial District of Sudbury.
OBC Div. B 3.1.1.6. Building in Flood Plains
Open OBC Div. B 3.1.1.6. in the code viewer(1)Buildings constructed on flood plains shall
(a)be designed and constructed in accordance with good engineering practice to withstand anticipated vertical and horizontal hydrostatic pressures acting on the structure, and
(b)incorporate floodproofing measures that will preserve the integrity of exits and means of egress during times of flooding.
OBC Div. B 9.1.1.8. Building in Flood Plains
Open OBC Div. B 9.1.1.8. in the code viewer(1)Buildings constructed on flood plains shall,
(a)be designed and constructed in accordance with good engineering practice to withstand anticipated vertical and horizontal hydrostatic pressures acting on the structure, and
(b)incorporate floodproofing measures that will preserve the integrity of exits and means of egress during times of flooding.
OBC Div. B 5.9.1.1. Compliance with Applicable Standards
Open OBC Div. B 5.9.1.1. in the code viewer(1)Except as provided in Sentence (2) and elsewhere in this Part, materials and components, and their installation, shall conform to the requirements of the applicable standards in Table 5.9.1.1. where those materials or components are
(a)incorporated into environmental separators or assemblies exposed to the exterior, and
(b)installed to fulfill the requirements of this Part. (See Note A-5.9.1.1.(1))
(2)The requirements for flame-spread ratings contained in thermal insulation standards shall be applied only as required in Part 3.
OBC Div. B 5.9.2.2. Applicable Standards
Open OBC Div. B 5.9.2.2. in the code viewer(1)Windows, doors and skylights shall conform to the requirements in
(a)AAMA/WDMA/CSA 101/I.S.2/A440, "North American Fenestration Standard/Specification for windows, doors, and skylights" (Harmonized Standard), and
(b)CSA A440S1, "Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, North American Fenestration Standard/Specification for windows, doors, and skylights."
(2)Performance grades for windows, doors and skylights shall be selected according to the Canadian Supplement referenced in Clause (1)(b) so as to be appropriate for the conditions and geographic location in which the window, door or skylight will be installed.
(3)Windows, doors and skylights shall conform to the performance grades selected in Sentence (2) when tested in accordance with the Harmonized Standard referenced in Clause (1)(a).
OBC Div. B 7.1.1A.1. Definitions
Open OBC Div. B 7.1.1A.1. in the code viewer(1)Except as provided in Sentence (2), words that appear in italics are defined in Article 1.4.1.2. of Division A and in the Building Code Act, 1992.
(2)In this Part,
Storey means the interval between two successive floor levels including mezzanine floors that contain plumbing fixtures or between a floor level and roof.
OBC Div. B 8.1.1.2. Definitions
Open OBC Div. B 8.1.1.2. in the code viewer(1)Except as provided in Sentence (2), words that appear in italics are defined in Article 1.4.1.2. of Division A and in the Building Code Act, 1992.
(2)In this Part,
Soil means in-situ, naturally occurring, unconsolidated mineral or organic material, at the earth's surface that is at least 100 mm thick and capable of supporting plant growth, and includes material compacted or cemented by soil forming processes, but does not include displaced materials such as gravel dumps, mine spoils, or like deposits.
OBC Div. B 9.1.1.1. Application
Open OBC Div. B 9.1.1.1. in the code viewer(1)The application of this Part shall be as described in Subsection 1.3.3. of Division A.
OBC Div. A 1.3.3.3. Application of Part 9
Open OBC Div. A 1.3.3.3. in the code viewer(1)Subject to Article 1.3.3.3B., Part 9 of Division B applies to all buildings described in Article 1.1.1.1. of 3 storeys or less in building height, having a building area not exceeding 600 m², and used for major occupancies classified as
(a)reserved
(b)Group C, residential occupancies other than buildings used for retirement homes, (See Note A-9.1.1.1.(1) of Division B)
(c)Group D, business and personal services occupancies,
(d)Group E, mercantile occupancies, or
(e)Group F, Divisions 2 and 3, medium- and low-hazard industrial occupancies.
OBC Div. B 9.1.1.9. Site Assembled and Factory-Built Buildings
Open OBC Div. B 9.1.1.9. in the code viewer(1)Except as provided in Sentence (2) and in Sentence 12.2.1.2.(2), a manufactured building is deemed to comply with this Code if it is designed and constructed in compliance with,
(a)CSA Z240.2.1, "Structural requirements for manufactured homes," if the building is constructed in sections not wider than 4.88 m, or
(b)CSA A277, "Procedure for certification of prefabricated buildings, modules, and panels."
(2)The requirements of this Code shall apply to,
(a)building components designed and constructed outside the place of manufacture, and
(b)site installation of such buildings.
OBC Div. B 9.10.1.1. Sloped Roofs
Open OBC Div. B 9.10.1.1. in the code viewer(1)For the purposes of this Section, roofs with slopes of 60° or more to the horizontal and that are adjacent to a room or space intended for occupancy shall be considered as a wall.
OBC Div. B 9.10.9.14. Residential Suites in Industrial Buildings
Open OBC Div. B 9.10.9.14. in the code viewer(1)Except as provided in Sentence (2), not more than one suite of residential occupancy shall be contained within a building classified as a Group F, Division 2 major occupancy.
(2)Except where a Group F Division 2 major occupancy is directly related to live/work units, not more than one suite of residential occupancy shall be contained within a building classified as Group F, Division 2 major occupancy.