Values this chapter turns on
- in the code: compliance, technical, administrative
- 3 Divisions
- in the code: compliance, technical, administrative
- to comply: acceptable or alternative solution
- 2 routes
- to comply: acceptable or alternative solution
- cutoff for amendments to referenced documents
- July 15, 2022
- cutoff for amendments to referenced documents
- water drop timed to find percolation time
- 1 cm
- water drop timed to find percolation time
Most On-site Sewage Systems candidates are installers and inspectors who live in Part 8. The exam still opens the book at Division A, because that is where the code says what it applies to, what the defined words mean, and how you are allowed to comply. These are usually quick marks. Learn where things are and you will not waste time on them.
How the code is organized
The 2024 Ontario Building Code (OBC) has three Divisions:
| Division | What it holds | What you use it for on this exam |
|---|---|---|
| A | Compliance, application, definitions, objectives, functional statements | Does Part 8 apply? What does "effluent" mean? |
| B | The acceptable solutions (the technical rules) | Part 8 and the listed Part 3, 4, 7, 9 and 11 items |
| C | Administrative provisions | Permits, inspections, maintenance inspection programs |
Division A holds the compliance and application rules plus the objectives and functional statements (OBC Div. A 1.3.1.1.OBC Div. A 1.3.1.1. Scope of Division A(1) Division A contains the compliance and application provisions, objectives and functional statements of this Code.). Division B holds the acceptable solutions (OBC Div. A 1.3.1.2.OBC Div. A 1.3.1.2. Scope of Division B(1) Division B contains the acceptable solutions of this Code.) and Division C the administrative provisions (OBC Div. A 1.3.1.3.OBC Div. A 1.3.1.3. Scope of Division C(1) Division C contains the administrative provisions of this Code.). If a provision points to another provision without naming a Division, it means the same Division (OBC Div. A 1.3.1.4.OBC Div. A 1.3.1.4. Internal Cross-References(1) Where the Division of a referenced provision is not specified in this Code, it shall mean that the referenced provision is in the same Division as the referencing provision.).
The code covers the construction, demolition, change of use and occupancy of buildings, whether built on site or in a factory (OBC Div. A 1.1.1.1.OBC Div. A 1.1.1.1. Application of this Code(1) This Code applies to the construction, demolition, change of use and occupancy of buildings. (2) This Code applies to both site-built and factory-constructed buildings. (See Note A-1.1.1.1.(2))). Why does that catch a septic system? Because the Building Code Act counts a sewage system as a "building" (BCA s. 1, "building"BCA s. 1 building“building” means, (a) a structure occupying an area greater than ten square metres consisting of a wall, roof and floor or any of them or a structural system serving the function thereof including all plumbing, works, fixtures and service systems appurtenant thereto, (b) a structure occupying an area of ten square…).
Application of Part 8
The key article is OBC Div. A 1.3.3.2A.OBC Div. A 1.3.3.2A. Application of Part 8(1) Subject to Article 1.3.3.3B., Part 8 of Division B applies to the design, construction, operation and maintenance of all sewage systems and to the construction of buildings in the vicinity of sewage systems.. Part 8 applies to:
- the design, construction, operation and maintenance of all sewage systems, and
- the construction of buildings in the vicinity of sewage systems.
So Part 8 is not only an installation standard. It also governs how an owner runs and maintains the system, and it limits where a new house or garage can go near an existing bed. Part 1 of Division B applies to all buildings (OBC Div. B 1.1.1.1.OBC Div. B 1.1.1.1. Application(1) This Part applies to all buildings covered in this Code.), and Parts 7 and 12 also apply to all buildings (OBC Div. A 1.3.3.1.OBC Div. A 1.3.3.1. Application of Parts 1, 7 and 12(1) Part 1 of Division B applies to all buildings covered in this Code. (See Article 1.1.1.1.) (2) Subject to Article 1.3.3.3B., Parts 7 and 12 of Division B apply to all buildings covered in this Code.).
For existing buildings, the code generally applies only to the new extension or the parts being altered or repaired, except where Section 3.18., Section 9.41. or Part 11 says otherwise (OBC Div. A 1.3.3.3C.OBC Div. A 1.3.3.3C. Existing Buildings(1) Except as provided in Section 3.18. of Division B, Section 9.41. of Division B and Part 11 of Division B, if an existing building is extended or is subject to material alteration or repair, this Code applies only to the design and construction of the extensions and those parts of the building that are subject to…). Part 11 applies to buildings that have existed for at least five years (OBC Div. A 1.3.3.3B.OBC Div. A 1.3.3.3B. Application of Part 11(1) Except as provided in Sentence (2), Part 11 of Division B applies to the design and construction of existing buildings, or parts of existing buildings, that have been in existence for at least five years. (2) If a building has been in existence for at least five years but includes an addition that has been in…). Chapter 11 covers these.
Two ways to comply
Compliance is achieved in one of two ways (OBC Div. A 1.2.1.1.OBC Div. A 1.2.1.1. Compliance with this Code(1) Compliance with this Code shall be achieved by (a) complying with the applicable acceptable solutions in Division B (See Note A-1.2.1.1.(1)(a)), or (b) using alternative solutions that will achieve at least the minimum level of performance required by the applicable acceptable solutions in respect of the…):
- Follow the applicable acceptable solutions in Division B, or
- Use an alternative solution that reaches at least the minimum level of performance of the acceptable solution, judged against the objectives and functional statements attributed to it in Supplementary Standard SA-1.
Materials and systems installed to meet the code must have the characteristics needed to do their job (OBC Div. A 1.2.2.1.OBC Div. A 1.2.2.1. Characteristics of Materials, Appliances, Systems and Equipment(1) All materials, appliances, systems and equipment installed to meet the requirements of this Code shall possess the necessary characteristics to perform their intended functions when installed in a building.). Used materials and equipment may be reused if they meet the requirements for new materials and suit the use (OBC Div. A 1.2.2.3.OBC Div. A 1.2.2.3. Used Materials, Appliances and Equipment(1) Unless otherwise specified, recycled materials in building products may be used, and used materials, appliances and equipment are permitted to be reused when they meet the requirements of this Code for new materials and are satisfactory for the intended use.).
Defined terms used in Part 8
Words shown in italics in the code are defined in OBC Div. A 1.4.1.2.OBC Div. A 1.4.1.2. Defined Terms(1) The words and terms in italics in this Code shall have the following meanings: (a) the same meaning as in subsection 1(1) of the Act, if not defined in Clause (b) or (c), (b) the same meaning as in each of the following provisions for the purposes described in the provision: (i) Sentences 1.4.1.3.(1) and (2) of… Part 8 adds one more: its own meaning of soil (OBC Div. B 8.1.1.2.OBC Div. B 8.1.1.2. Definitions(1) Except as provided in Sentence (2), words that appear in italics are defined in Article 1.4.1.2. of Division A and in the Building Code Act, 1992. (2) In this Part, Soil means in-situ, naturally occurring, unconsolidated mineral or organic material, at the earth's surface that is at least 100 mm thick and capable…), covered in Chapter 5. Words that are not defined take their ordinary meaning in the trade (OBC Div. A 1.4.1.1.OBC Div. A 1.4.1.1. Non-defined Terms(1) Words and phrases used in this Code that are not included in the list of definitions in Articles 1.4.1.2., 1.4.1.3. and 1.4.1.4. and are not defined in another provision of this Code shall have the meanings that are commonly assigned to them in the context in which they are used, taking into account the…).
The definitions an installer is most often tested on:
| Term | What it means, in short |
|---|---|
| Effluent | sanitary sewage that has passed through a treatment unit (def.OBC Div. A 1.4.1.2.(1) EffluentEffluent means sanitary sewage that has passed through a treatment unit.) |
| Greywater | domestic sanitary sewage from fixtures other than sanitary units (def.OBC Div. A 1.4.1.2.(1) GreywaterGreywater means sanitary sewage of domestic origin that is derived from fixtures other than sanitary units.) |
| Sanitary unit | a water closet, urinal, bidet or bedpan washer (def.OBC Div. A 1.4.1.2.(1) Sanitary unitSanitary unit means a water closet, urinal, bidet or bedpan washer.) |
| Septic tank | a watertight vault where solids settle and anaerobic digestion happens, with no added air (def.OBC Div. A 1.4.1.2.(1) Septic tankSeptic tank means a watertight vault in which sanitary sewage is collected for the purpose of removing scum, grease and solids from the liquid without the addition of air and in which solids settling and anaerobic digestion of the sanitary sewage takes place.) |
| Holding tank | a tank that keeps all the sewage it receives and must be emptied periodically (def.OBC Div. A 1.4.1.2.(1) Holding tankHolding tank means a tank designed to totally retain all sanitary sewage discharged into it and requiring periodic emptying.) |
| Treatment unit | a device that reduces the contaminant load of sanitary sewage to a given effluent quality (def.OBC Div. A 1.4.1.2.(1) Treatment unitTreatment unit means a device that, when designed, installed and operated in accordance with its design specifications, provides a specific degree of sanitary sewage treatment to reduce the contaminant load from that of sanitary sewage to a given effluent quality.) |
| Percolation time | average minutes for water to drop one centimetre in a percolation test, or as found by soil evaluation (def.OBC Div. A 1.4.1.2.(1) Percolation timePercolation time means the average time in minutes that is required for water to drop one centimetre during a percolation test or as determined by a soil evaluation or analysis.) |
| High ground water table | the highest level with physical evidence that the soil or fill has been saturated (def.OBC Div. A 1.4.1.2.(1) High ground water tableHigh ground water table means the highest elevation at which there is physical evidence that the soil, as defined in Part 8 of Division B, or the leaching bed fill has been saturated with water.) |
| Leaching bed fill | material placed to give the needed unsaturated zone and lateral extent under the pipes or chambers (def.OBC Div. A 1.4.1.2.(1) Leaching bed fillLeaching bed fill means unconsolidated material suitable for the construction of a leaching bed, placed in the area of the leaching bed in order to obtain the required unsaturated zone below the distribution pipes or leaching chambers and the required lateral extent such that the effluent is absorbed.) |
| Header line | watertight pipe carrying effluent from the treatment unit to the distribution pipe (def.OBC Div. A 1.4.1.2.(1) Header lineHeader line means a line of pipe with watertight joints installed in a sewage system for the purpose of distributing effluent from a treatment unit to the distribution pipe in a leaching bed.) |
| Distribution box | a device that splits effluent equally between lines (def.OBC Div. A 1.4.1.2.(1) Distribution boxDistribution box means a device for ensuring that effluent from a treatment unit is distributed in equal amounts to each line of distribution pipe or leaching chamber in a leaching bed.) |
| Shallow buried trench | an absorption trench containing a chamber or leaching chamber (def.OBC Div. A 1.4.1.2.(1) Shallow buried trenchShallow buried trench means an absorption trench that contains a chamber or leaching chamber.) |
Watch the pairs that look alike. Header line has watertight joints; distribution pipe is perforated or open jointed (def.OBC Div. A 1.4.1.2.(1) Distribution pipeDistribution pipe means a line or lines of perforated or open jointed pipe or tile installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.). A chamber (open bottom, holds a pressurized pipe, used in a shallow buried trench) is not the same as a leaching chamber (open bottom and permeable sidewalls) (def.OBC Div. A 1.4.1.2.(1) ChamberChamber means a structure in a shallow buried trench that is constructed with an open bottom and that contains a pressurized distribution pipe., def.OBC Div. A 1.4.1.2.(1) Leaching chamberLeaching chamber means a formed structure with an open bottom and permeable sidewalls installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.). Also note "ground water" has a Part 8 meaning tied to the saturated zone of the earth's mantle (def.OBC Div. A 1.4.1.2.(1) Ground waterGround water means, when applied to a sewage system, water below the surface of the ground that occupies a zone of the earth's mantle that is saturated with water.).
Objectives and functional statements
Objectives sit in OBC Div. A 2.2.1.1.OBC Div. A 2.2.1.1. Objectives(1) The objectives of this Code are as follows: (See Note A-2.2.1.1.(1)) OS Safety An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in or adjacent to the building will be exposed to an unacceptable risk of injury. OS1 Fire Safety An… and functional statements in OBC Div. A 3.2.1.1.OBC Div. A 3.2.1.1. Functional Statements(1) The objectives of this Code are achieved by measures, such as those described in the acceptable solutions in Division B, that are intended to allow the building or its elements to perform the following functions: (See Note A-3.2.1.1.(1)) F01 To minimize the risk of accidental ignition. F02 To limit the severity…. The ones that matter for sewage systems:
| Code | Theme |
|---|---|
| OH2 | Sanitation; OH2.1 is exposure to human or domestic waste, OH2.2 is consumption of contaminated water |
| OE2 | Water and soil quality (environmental integrity) |
| F72 | Facilities for sanitary disposal of human and domestic wastes |
| F110 | Control release of contaminants into soil, groundwater, surface water and air |
| F111 | Minimize risk of malfunction, damage or failure of a sewage system |
| F112 | Adequate treatment of sanitary sewage and effluent |
| F113 | Minimize injury from contact with sanitary sewage or partly treated effluent |
The F110 to F113 group is written for sewage systems. If a question asks which functional statement is about "adequate treatment", it is F112.
Referenced documents
Part 8 points to several outside documents: CSA B66 for prefabricated tanks, CAN/BNQ 3680-600 for treatment unit levels, NSF/ANSI 46 for effluent filters, IAPMO PS 63 for plastic leaching chambers and CSA B481 for grease interceptors. You are not expected to know what is inside them. You are expected to know:
- Referenced documents include amendments effective to July 15, 2022, unless the code says otherwise (OBC Div. B 1.3.1.1.OBC Div. B 1.3.1.1. Effective Date(1) Unless otherwise specified in this Code, the documents referenced in this Code shall include all amendments, revisions, reaffirmations, reapprovals, addenda and supplements effective to July 15, 2022.).
- The edition is the one listed in Table 1.3.1.2. (OBC Div. B 1.3.1.2.OBC Div. B 1.3.1.2. Applicable Editions(1) Where documents are referenced in this Code, they shall be in the editions designated in Table 1.3.1.2.). That table also tells you which code articles cite each document.
- If the code and a referenced document conflict, the code governs (OBC Div. A 1.5.1.2.OBC Div. A 1.5.1.2. Conflicting Requirements(1) In case of conflict between the provisions of this Code and those of a referenced document, the provisions of this Code shall govern.).
Worked example: which document?
An inspector asks which standard the effluent filter on a new septic tank must meet. Part 8 names NSF/ANSI 46 in OBC Div. B 8.6.2.1.OBC Div. B 8.6.2.1. Septic Tank Systems(1) An effluent filter shall be installed in the outlet flow path of every septic tank that discharges effluent to a leaching bed. (2) The septic tank effluent filter required by Sentence (1) shall, (a) conform to the requirements of NSF/ANSI 46, "Evaluation of Components and Devices Used in Wastewater Treatment…. Table 1.3.1.2. (TableOBC Div. B Table 1.3.1.2. Documents Referenced in the Building Code — Forming Part of Sentence 1.3.1.2.(1)Table 1.3.1.2. Documents Referenced in the Building Code — Forming Part of Sentence 1.3.1.2.(1) Issuing Agency | Document Number | Title of Document | Code Reference ACGIH | 2013, 28th Edition | Industrial Ventilation: A Manual of Recommended Practice for Design | 2.4.2.5.(1) 6.2.1.1.(1) 6.3.2.14.(2) ACI | 355.2-19 |…) confirms the edition and lists 8.6.2.1.(2) as the citing provision.
Common traps
- Part 8 reaches buildings too. A new garage near a leaching bed is controlled by Part 8 clearances.
- "Soil" has two meanings. The Division A definition does not apply to Part 8, which has its own.
- Effluent vs sanitary sewage. It is only effluent after it passes through a treatment unit.
- Header line vs distribution pipe. Watertight vs perforated.
- Alternative solutions must match the performance level tied to SA-1, not just "work".
Chapter review
Chapter at a glance
One line per section: the idea to carry into the exam. Then the answers that most often catch candidates out.
- How the code is organized
Division A holds the compliance and application rules plus the objectives and functional statements.
- Application of Part 8
So Part 8 is not only an installation standard.
- Two ways to comply
Materials and systems installed to meet the code must have the characteristics needed to do their job.
- Defined terms used in Part 8
Words shown in italics in the code are defined in Part 8 adds one more: its own meaning of soil, covered in Chapter 5. Words that are not defined take their ordinary meaning in…
- Objectives and functional statements
The F110 to F113 group is written for sewage systems.
- Referenced documents
Part 8 points to several outside documents: CSA B66 for prefabricated tanks, CAN/BNQ 3680-600 for treatment unit levels, NSF/ANSI 46 for effluent filters, IAPMO PS 63 for plastic…
Usual exam traps
- Part 8 reaches buildings too. A new garage near a leaching bed is controlled by Part 8 clearances.
- "Soil" has two meanings. The Division A definition does not apply to Part 8, which has its own.
- Effluent vs sanitary sewage. It is only effluent after it passes through a treatment unit.
- Header line vs distribution pipe. Watertight vs perforated.
- Alternative solutions must match the performance level tied to SA-1, not just "work".
Practice this chapter
Questions on Code structure, objectives and referenced documents, in the exam format, every answer explained and cited to its article. Sign in to start; a free account gets the free questions.
Code cited in this chapter
Based on the official 2024 Building Code Compendium on ontario.ca.
© King's Printer for Ontario, 2024. Reproduced with permission.
OBC Div. A 1.3.1.1. Scope of Division A
Open OBC Div. A 1.3.1.1. in the code viewer(1)Division A contains the compliance and application provisions, objectives and functional statements of this Code.
OBC Div. A 1.3.1.2. Scope of Division B
Open OBC Div. A 1.3.1.2. in the code viewer(1)Division B contains the acceptable solutions of this Code.
OBC Div. A 1.3.1.3. Scope of Division C
Open OBC Div. A 1.3.1.3. in the code viewer(1)Division C contains the administrative provisions of this Code.
OBC Div. A 1.3.1.4. Internal Cross-References
Open OBC Div. A 1.3.1.4. in the code viewer(1)Where the Division of a referenced provision is not specified in this Code, it shall mean that the referenced provision is in the same Division as the referencing provision.
OBC Div. A 1.1.1.1. Application of this Code
Open OBC Div. A 1.1.1.1. in the code viewer(1)This Code applies to the construction, demolition, change of use and occupancy of buildings.
(2)This Code applies to both site-built and factory-constructed buildings. (See Note A-1.1.1.1.(2))
BCA s. 1 building
Open BCA s. 1 in the code viewer“building” means,
(a)a structure occupying an area greater than ten square metres consisting of a wall, roof and floor or any of them or a structural system serving the function thereof including all plumbing, works, fixtures and service systems appurtenant thereto,
(b)a structure occupying an area of ten square metres or less that contains plumbing, including the plumbing appurtenant thereto,
(c)plumbing not located in a structure,
(c.1) a sewage system, or
(d)structures designated in the building code; (“bâtiment”)
OBC Div. A 1.3.3.2A. Application of Part 8
Open OBC Div. A 1.3.3.2A. in the code viewer(1)Subject to Article 1.3.3.3B., Part 8 of Division B applies to the design, construction, operation and maintenance of all sewage systems and to the construction of buildings in the vicinity of sewage systems.
OBC Div. B 1.1.1.1. Application
Open OBC Div. B 1.1.1.1. in the code viewer(1)This Part applies to all buildings covered in this Code.
Show all 40 articles
OBC Div. A 1.3.3.1. Application of Parts 1, 7 and 12
Open OBC Div. A 1.3.3.1. in the code viewer(1)Part 1 of Division B applies to all buildings covered in this Code. (See Article 1.1.1.1.)
(2)Subject to Article 1.3.3.3B., Parts 7 and 12 of Division B apply to all buildings covered in this Code.
OBC Div. A 1.3.3.3C. Existing Buildings
Open OBC Div. A 1.3.3.3C. in the code viewer(1)Except as provided in Section 3.18. of Division B, Section 9.41. of Division B and Part 11 of Division B, if an existing building is extended or is subject to material alteration or repair, this Code applies only to the design and construction of the extensions and those parts of the building that are subject to the material alteration or repair.
(2)If an existing previously occupied building is moved from its original location to be installed elsewhere, or is dismantled at its original location and moved to be reconstituted elsewhere, this Code applies only to changes to the design and construction of the building required as a result of moving the building.
OBC Div. A 1.3.3.3B. Application of Part 11
Open OBC Div. A 1.3.3.3B. in the code viewer(1)Except as provided in Sentence (2), Part 11 of Division B applies to the design and construction of existing buildings, or parts of existing buildings, that have been in existence for at least five years.
(2)If a building has been in existence for at least five years but includes an addition that has been in existence for less than five years, Part 11 of Division B applies to the entire building.
OBC Div. A 1.2.1.1. Compliance with this Code
Open OBC Div. A 1.2.1.1. in the code viewer(1)Compliance with this Code shall be achieved by
(a)complying with the applicable acceptable solutions in Division B (See Note A-1.2.1.1.(1)(a)), or
(b)using alternative solutions that will achieve at least the minimum level of performance required by the applicable acceptable solutions in respect of the objectives and functional statements attributed to the applicable acceptable solutions in Ministry of Municipal Affairs and Housing (MMAH) Supplementary Standard SA-1, "Objectives and Functional Statements Attributed to the Acceptable Solutions." (See Note A-1.2.1.1.(1)(b))
(2)For the purposes of Clause (1)(b), the level of performance in respect of a functional statement refers to the performance of the functional statement as it relates to the objective with which it is associated in MMAH Supplementary Standard SA-1, "Objectives and Functional Statements Attributed to the Acceptable Solutions."
OBC Div. A 1.2.2.1. Characteristics of Materials, Appliances, Systems and Equipment
Open OBC Div. A 1.2.2.1. in the code viewer(1)All materials, appliances, systems and equipment installed to meet the requirements of this Code shall possess the necessary characteristics to perform their intended functions when installed in a building.
OBC Div. A 1.2.2.3. Used Materials, Appliances and Equipment
Open OBC Div. A 1.2.2.3. in the code viewer(1)Unless otherwise specified, recycled materials in building products may be used, and used materials, appliances and equipment are permitted to be reused when they meet the requirements of this Code for new materials and are satisfactory for the intended use.
OBC Div. A 1.4.1.2. Defined Terms
Open OBC Div. A 1.4.1.2. in the code viewer(1)The words and terms in italics in this Code shall have the following meanings:
(a)the same meaning as in subsection 1(1) of the Act, if not defined in Clause (b) or (c),
(b)the same meaning as in each of the following provisions for the purposes described in the provision:
(i)Sentences 1.4.1.3.(1) and (2) of Division A, and
(ii)Sentences 3.13.1.2.(1), 7.1.1A.1.(1), 8.1.1.2.(1) and 11.1.1.2.(1) of Division B, or
(c)the following meaning for the purposes of this Code:
Absorption trench means an excavation in soil, as defined in Part 8 of Division B, or in leaching bed fill, being part of a leaching bed, in which a distribution pipe or leaching chamber is laid that allows infiltration of the effluent into the soil, as defined in Part 8 of Division B, or leaching bed fill.
Acceptable solution means a requirement stated in Parts 2 to 12 of Division B.
Accessible means, when applied to a fixture, connection, plumbing appliance, valve, cleanout or equipment, to be accessible with or without having to first remove an access panel, door or similar obstruction, but a fixture, connection, plumbing appliance, valve, cleanout or equipment is not accessible if access can be gained only by cutting or breaking materials.
Access to exit means that part of a means of egress within a floor area that provides access to an exit serving the floor area.
Adaptable seating means a fixed seat or seats designed to facilitate a side transfer from a wheelchair. (See Note A-1.4.1.2.(1))
Additional circuit vent means a vent pipe that is installed between a circuit vent and a relief vent to provide additional air circulation.
Adfreezing means the adhesion of soil to a foundation unit resulting from the freezing of soil water. (Also referred to as "frost grip.")
Agricultural occupancy (Group G) means the occupancy of a building or part thereof that is located on land that is associated with and devoted to the practice of farming, and is used for the purpose of producing crops, raising farm animals, or preparing, marketing, storing or processing agricultural products. (See Note A-1.4.1.2.(1))
Agricultural occupancy with no human occupants (Group G, Division 4) means an agricultural occupancy that is not intended to be occupied by persons under normal use and is generally used for the storage of agricultural materials and by-products. (See Note A-1.4.1.2.(1))
Air admittance valve means a one-way valve designed to allow air to enter the drainage system when the pressure in the plumbing system is less than the atmospheric pressure.
Air barrier system means the assembly installed to provide a continuous barrier to the movement of air.
Air break means the unobstructed vertical distance between the lowest point of an indirectly connected waste pipe and the flood level rim of the fixture into which it discharges.
Air-conditioning means the process of treating air in a space to control simultaneously its temperature, humidity, cleanliness, and distribution to meet the comfort requirements of the occupants of the space.
Air gap means the unobstructed vertical distance through air between the lowest point of a water supply outlet and the flood level rim of the fixture or device into which the outlet discharges.
Air-supported structure means a structure consisting of a pliable membrane that achieves and maintains its shape and support by internal air pressure.
Alarm signal means an audible signal transmitted throughout a zone or zones or throughout a building to advise occupants that a fire emergency exists.
Alert signal means an audible signal to advise designated persons of a fire emergency.
Allowable bearing pressure means the maximum pressure that may be safely applied to a soil or rock by the foundation unit considered in design under expected loading and subsurface conditions.
Allowable load means the maximum load that may be safely applied to a foundation unit considered in design under expected loading and subsurface conditions.
Alloyed zinc means an alloy of zinc having the corrosion resistance and physical properties of an alloy containing 0.15% titanium, 0.74% copper and 99.11% zinc, and so tempered as to be capable of being formed into the shape required for a watertight joint.
Alternative solution means a substitute for an acceptable solution.
Apparent sound transmission class (ASTC) means a single number rating of the airborne sound attenuation of building assemblies separating two adjoining spaces, taking into account both the direct and flanking sound transmission paths. (See Note A-1.4.1.2.(1)) (See also Note A-9.11. of Division B)
Appliance means a device to convert fuel into energy and includes all components, controls, wiring and piping required to be part of the device by the applicable standard referred to in this Code.
Architect means the holder of a licence, a certificate of practice or a temporary licence under the Architects Act.
Area affected by a significant drinking water threat means an area described in Clause 1.10.2.3.(2)(b) of Division C.
Artesian groundwater means a confined body of water under pressure in the ground.
As constructed plans means construction plans and specifications that show the building and the location of the building on the property as the building has been constructed.
Assembly occupancy (Group A) means the occupancy or the use of a building or part thereof by a gathering of persons for civic, political, travel, religious, social, educational, recreational or like purposes, or for the consumption of food or drink.
Attic or roof space means the space between the roof and the ceiling of the top storey or between a dwarf wall and a sloping roof.
auxiliary water supply means, when applied to premises, any water supply on or available to the premises other than the primary potable water supply for the premises.
Backflow means a flowing back or reversal of the normal direction of the flow.
Backflow preventer means a device or a method that prevents backflow in a water distribution system.
Back pressure means pressure higher than the supply pressure.
Back-siphonage means backflow caused by a negative pressure in the supply system.
Back-siphonage preventer means a device or a method that prevents back-siphonage in a water distribution system.
Back vent means a pipe that is installed to vent a trap off the horizontal section of a fixture drain or the vertical leg of a water closet or other fixture that has an integral siphonic flushing action and "back vented" has a corresponding meaning.
Backwater valve means a check valve designed for use in a gravity drainage system.
Barrier-free means, when applied to a building and its facilities, that the building and its facilities can be approached, entered and used by persons with physical or sensory disabilities.
Basement means a storey or storeys of a building located below the first storey.
Bathroom group means a group of plumbing fixtures installed in the same room, consisting of one domestic-type lavatory, one water closet and either one bathtub, with or without a shower, or one one-headed shower.
Bearing surface means the contact surface between a foundation unit and the soil or rock upon which it bears.
Boarding, lodging or rooming house means a building
(a) that has a building height not exceeding three storeys and a building area not exceeding 600 m²,
(b) in which lodging is provided for more than four persons in return for remuneration or for the provision of services or for both, and
(c) in which the lodging rooms do not have both bathrooms and kitchen facilities for the exclusive use of individual occupants.
Boiler means an appliance intended to supply hot water or steam for space heating, processing or power purposes.
Bottle trap means a trap that retains water in a closed chamber and that seals the water by submerging the inlet pipe in the liquids or by a partition submerged in the liquids.
Braced wall band means an imaginary continuous straight band extending vertically and horizontally through the building or part of the building, within which braced wall panels are constructed.
Braced wall panel means a portion of a wood-frame wall where bracing, sheathing, cladding or interior finish is designed and installed to provide the required resistance to lateral loads due to wind or earthquake.
Branch means a sanitary drainage pipe that is connected at its upstream end to the junction of two or more sanitary drainage pipes or to a stack connected at its downstream end to another branch, a sump, a stack or a building drain.
Branch vent means a vent pipe that is connected at its lower end to the junction of two or more vent pipes and at its upper end either to another branch vent, or to a stack vent, vent stack or vent header, or terminates in open air.
Breeching means a flue pipe or chamber for receiving flue gases from one or more flue connections and for discharging these gases through a single flue connection.
Building area means the greatest horizontal area of a building above grade within the outside surface of exterior walls or within the outside surface of exterior walls and the centre line of firewalls.
Building Code website means the website at www.ontario.ca/buildingcode.
Building control valve means the valve on a water system that controls the flow of potable water from the water service pipe to the water distribution system.
Building drain means the lowest horizontal piping, including any vertical offset, that conducts sewage, clear water waste or storm water by gravity to a building sewer.
Building height (in storeys) means the number of storeys contained between the roof and the floor of the first storey.
Building sewer means a pipe that is connected to a building drain 1 m outside a wall of a building and that leads to a public sewer or private sewage disposal system.
Building trap means a trap that is installed in a building drain or sanitary building sewer to prevent the circulation of air between the sanitary drainage system and a public sewer.
Business and personal services occupancy (Group D) means the occupancy or use of a building or part thereof for the transaction of business or the provision of professional or personal services.
Caisson (see Pile).
Camp for housing of workers means a camp in which buildings or other structures or premises are used to accommodate five or more employees.
Campground means land or premises used as an overnight camping facility that is not a recreational camp.
Canopy means a roof-like structure projecting more than 300 mm from the exterior face of the building.
Carbon dioxide equivalent means a measure used to compare the impact of various greenhouse gases based on their global warming potential.
Carbon monoxide alarm means a carbon monoxide detection device with an integral audible alarm device designed to sound an alarm within the room, suite or space in which it is located when the concentration of airborne carbon monoxide exceeds a pre-determined level and duration.
Care and treatment occupancy (Group B, Division 2) means an occupancy in which persons receive special care and treatment.
Care occupancy (Group B, Division 3) means an occupancy, other than a retirement home, in which special care is provided by a facility, directly through its staff or indirectly through another provider, to residents of the facility
(a) who require special care because of cognitive or physical limitations, and
(b) who, as a result of those limitations, would be incapable of evacuating the occupancy, if necessary, without the assistance of another person.
Cavity wall means a construction of masonry units laid with a cavity between the wythes. The wythes are tied together with metal ties or bonding units, and are relied on to act together in resisting lateral loads.
Certificate for the occupancy of a building described in Sentence 1.3.3.4.(3) of Division C means a certificate described in Sentence 3.7.4.3.(6) of Division C.
Certificate for the occupancy of a building described in Sentence 1.3.3.5.(1) of Division C means a certificate described in Sentence 3.7.4.3.(7) of Division C.
Certificate for the occupancy of a building not fully completed means a certificate described in Sentence 3.7.4.3.(5) of Division C.
Chamber means a structure in a shallow buried trench that is constructed with an open bottom and that contains a pressurized distribution pipe.
Check valve means a valve that permits flow in only one direction and prevents a return flow.
Child care centre means a child care centre as defined in subsection 2 (1) of the Child Care and Early Years Act, 2014.
Chimney means a primarily vertical shaft enclosing at least one flue for conducting flue gases to the outdoors.
Chimney liner means a conduit containing a chimney flue used as a lining of a masonry or concrete chimney.
Circuit vent means a vent pipe that serves a number of fixtures and connects to the fixture drain of the most upstream fixture, and "circuit vented" has a corresponding meaning.
Class 1 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets, is directly connected to the public water supply main only, has no pumps or reservoirs and in which the sprinkler drains discharge to the atmosphere, to dry wells or to other safe outlets.
Class 2 fire sprinkler/standpipe system means a Class 1 fire sprinkler/standpipe system that includes a booster pump in its connection to the public water supply main.
Class 3 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys potable water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets and that is directly connected to the public water supply main as well as to one or more of the following storage facilities, which are filled from the public water supply main only: elevated water storage, fire pumps supplying water from aboveground covered reservoirs or pressure tanks. The water in this sprinkler/standpipe system must be maintained in potable condition.
Class 4 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets and is directly connected to the public water supply main (similar to Class 1 and Class 2 fire sprinkler/standpipe systems) and to an auxiliary water supply dedicated to fire department use that is located within 520 m of a pumper connection.
Class 5 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets, is directly connected to the public water supply main and also interconnected with an auxiliary water supply.
Class 6 fire sprinkler/standpipe system means an assembly of pipes and fittings that conveys water from the water service pipe or fire service main to the sprinkler/standpipe system's outlets and acts as a combined industrial water supply and fire protection system that is supplied from the public water supply main only, with or without gravity storage or pump suction tanks.
Cleanout means a fitting access in a drainage system or venting system that is installed to provide access for cleaning and inspection and that is provided with a readily replaceable air tight cover.
Clean water means water that has passed through a recirculation system.
Clear-water waste means waste water with impurity levels that will not be harmful to health and may include cooling water and condensate drainage from refrigeration and air-conditioning equipment and cooled condensate from steam heating systems, but does not include storm water.
Closed container means a container so sealed by means of a lid or other device that neither liquid nor vapour will escape from it at ordinary temperatures.
Closure means a device or assembly for closing an opening through a fire separation or an exterior wall, such as a door, a shutter, a damper, wired glass or glass block, and includes all components such as hardware, closing devices, frames and anchors.
Combustible means that a material fails to meet the acceptance criteria of CAN/ULC-S114, "Standard Method of Test for Determination of Non-Combustibility in Building Materials."
Combustible construction means that type of construction that does not meet the requirements for noncombustible construction or encapsulated mass timber construction.
Combustible dusts means dusts and particles that are ignitable and liable to produce an explosion.
Combustible fibres means finely divided, combustible vegetable or animal fibres and thin sheets or flakes of such materials which, in a loose, unbaled condition, present a flash fire hazard, including cotton, wool, hemp, sisal, jute, kapok, paper and cloth.
Combustible liquid means a liquid having a flash point at or above 37.8°C and below 93.3°C.
Compliance alternative means a substitute for a requirement in another Part of Division B that is listed in Part 10 or 11 of Division B, and "C.A." has a corresponding meaning.
Compressed gas means
(a) any contained mixture or material having a vapour pressure exceeding one or both of the following:
(i)275.8 kPa (absolute) at 21°C, or
(ii)717 kPa (absolute) at 54°C, or
(b) any liquid having a vapour pressure exceeding 275.8 kPa (absolute) at 37.8°C.
Computer room means a room
(a) that contains electronic computer or data processing equipment such as main frame type,
(b) that is separated from the remainder of the building for the purpose of controlling the air quality in the room by a self-contained climate control system, and
(c) that has an occupant load of not more than one person for each 40 m² of the room.
Conditioned space means any space within a building, the temperature of which is controlled to limit variation in response to the exterior ambient temperature by the provision, either directly or indirectly, of heating or cooling over substantial portions of the year.
Construction index means a level on a scale of 1 to 8 determined in accordance with Table 11.2.1.1.-A of Division B designating the expected performance level of the building structure with respect to the type of construction and fire protection of an existing building, and "C.I." has a corresponding meaning.
Contained use area means a supervised area containing one or more rooms in which occupant movement is restricted to a single room by security measures not under the control of the occupant.
Continuous vent means a vent pipe that is an extension of a vertical section of a branch or fixture drain.
Cooktop means a cooking surface having one or more burners or heating elements.
Critical level means the level of submergence at which a back-siphonage preventer ceases to prevent back-siphonage.
Dangerous goods means products, materials or substances that are
(a) regulated by TC SOR/2001-286, "Transportation of Dangerous Goods Regulations (TDGR)", or (See Table 3.2.7.1. of Division B of CCBFC NRCC-CONST-56437E, "National Fire Code of Canada")
(b) classified as controlled products under HC SOR/2015-17, "Hazardous Products Regulations". (See Note A-Table 3.2.7.1. of Division B of CCBFC NRCC-CONST-56437E, "National Fire Code of Canada")
Day camp means a camp or resort that admits persons for a continuous period not exceeding 24 hours.
Dead end means a pipe that terminates with a closed fitting.
Dead load means the weight of all permanent structural and non-structural components of a building.
Deep foundation means a foundation unit that provides support for a building by transferring loads either by end-bearing to soil or rock at considerable depth below the building, or by adhesion or friction, or both, in the soil or rock in which it is placed. Piles are the most common type of deep foundation.
Demountable stage means a structure that
(a) consists of one or more platforms together with any wall, roof or other structures attached to or located on any of the platforms,
(b) is intended to be used for public or private performances or events, other than performances or events associated with movie or television productions,
(c) is intended to be erected, assembled or installed for a limited specified time,
(d)is capable of being dismantled at its location and moved to be reconstituted elsewhere or is erected for one-time use,
(e)is not located inside a fully enclosed building,
(f)is primarily for use by performers and workers, and
(g)may or may not be mounted on wheels.
Demountable support structure means any structure that
(a) is capable of supporting banners, stage sets, props, sound equipment, lighting equipment or other equipment,
(b) is intended to be used for public or private performances or events, other than performances or events associated with movie or television productions,
(c) is intended to be erected, assembled or installed for a limited specified time,
(d) is capable of being dismantled at its location and moved to be reconstituted elsewhere or is erected for one-time use,
(e) is not attached to or located on a demountable stage,
(f) is not located inside a fully enclosed building,
(g) is primarily for use by performers and workers, and
(h)may or may not be mounted on wheels.
Design activities means the activities described in subsection 15.11(5) of the Act.
Design bearing pressure means the pressure applied by a foundation unit to soil or rock , which pressure is not greater than the allowable bearing pressure.
Design capacity means, in the definition of sewage system , the total daily design sanitary sewage flow determined in accordance with Article 8.2.1.3. of Division B.
Designer means the person responsible for the design.
Design load means the load applied to a foundation unit , which load is not greater than the allowable load.
Detention occupancy (Group B, Division 1) means the occupancy by persons who are restrained from or are incapable of evacuating to a safe location without the assistance of another person because of security measures not under their control.
Developed length means, the length along the centre line of the pipe and fittings.
Direct-vented (as applying to a fuel-fired space- or water-heating appliance) means an appliance and its venting system in which all the combustion air is supplied directly from the outdoors and the products of combustion are vented directly to the outdoors via independent, totally enclosed passageways connected directly to the appliance.
Directly connected means physically connected in such a way that neither water or gas can escape from the connection.
Distilled beverage alcohol means a beverage that is produced by fermentation and contains more than 20% by volume of water-miscible alcohol.
Distillery means a process plant where distilled beverage alcohols are produced, concentrated or otherwise processed, and includes facilities on the same site where the concentrated products may be blended, mixed, stored or packaged.
Distributing pipe means a pipe or piping in a water distribution system.
Distribution box means a device for ensuring that effluent from a treatment unit is distributed in equal amounts to each line of distribution pipe or leaching chamber in a leaching bed.
Distribution pipe means a line or lines of perforated or open jointed pipe or tile installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.
Diving board means a flexible board.
Diving platform means a rigid platform that is not a starting platform.
Drainage system means an assembly of pipes, fittings, fixtures and appurtenances on a property that is used to convey sewage and clear water waste to a main sewer or a private sewage disposal system, and includes a private sewer, but does not include subsoil drainage piping.
Drinking water system has the same meaning as in subsection 2(1) of the Safe Drinking Water Act, 2002.
Drum trap means a trap whose inlet and outlet are in the sides of the cylindrical body of the trap.
Dual vent means a vent pipe that serves two fixtures and connects at the junction of the trap arms.
Dwelling unit means a suite operated as a housekeeping unit, used or intended to be used by one or more persons and usually containing cooking, eating, living, sleeping and sanitary facilities.
Earth pit privy means a latrine consisting of an excavation in the ground surmounted by a superstructure.
Effluent means sanitary sewage that has passed through a treatment unit.
Electric space heating means an electric energy source that provides more than 10 percent of the heating capacity provided for a building and includes
(a) electric resistance unitary baseboard heating,
(b) electric resistance unitary cabinet heating,
(c) electric resistance ceiling cable or floor cable heating,
(d) electric resistance central furnace heating,
(e) electric hot water space heating, and
(f) air source heat pumps in combination with electric resistance backup heating.
Encapsulated mass timber construction means that type of construction in which a degree of fire safety is attained by the use of encapsulated mass timber elements with an encapsulation rating and minimum dimensions for structural members and other building assemblies.
Encapsulation rating means the time in minutes that a material or assembly of materials will delay the ignition and combustion of encapsulated mass timber elements when it is exposed to fire under specified conditions of test and performance criteria, or as otherwise prescribed by this Code.
Excavation means the space created by the removal of soil, rock or fill for the purposes of construction.
Exhaust duct means a duct through which air is conveyed from a room or space to the outdoors.
Exit means that part of a means of egress, including doorways, that leads from the floor areait serves to a separate building, an open public thoroughfare, or an exterior open space protected from fire exposure from the building and having access to an open public thoroughfare. (See Note A-1.4.1.2.(1))
Exit level means the level of an exit stairway at which an exterior exit door or exit passageway leads to the exterior.
Exit storey (as applying to Subsection 3.2.6. of Division B) means a storey having an exterior exit door.
Exposing building face means that part of the exterior wall of a building that faces one direction and is located between ground level and the ceiling of its top storey or, where a building is divided into fire compartments, the exterior wall of a fire compartment that faces one direction.
Exterior cladding means those components of a building that are exposed to the outdoor environment and are intended to provide protection against wind, water or vapour.
Factory-built chimney means a chimney consisting entirely of factory-made parts, each designed to be assembled with the other without requiring fabrication on site.
Farm building means a building or part thereof that contains an agricultural occupancy. (See Note A-1.4.1.2.(1))
Fill means soil, rock, rubble, industrial waste such as slag, organic material or a combination of these that is transported and placed on the natural surface of soil or rock or organic terrain. It may or may not be compacted.
Fire block means a material, component or system that restricts the spread of fire within a concealed space or from a concealed space to an adjacent space.
Fire compartment means an enclosed space in a building that is separated from all other parts of the building by enclosing construction providing a fire separation having a required fire-resistance rating.
Fire damper means a closure consisting of a damper that is installed in an air distribution system or a wall or floor assembly and that is normally held open but designed to close automatically in the event of a fire in order to maintain the integrity of the fire separation.
Fire detector means a device that detects a fire condition and automatically initiates an electrical signal to actuate an alert signal or alarm signal and includes heat detectors and smoke detectors.
Fire load (as applying to an occupancy) means the combustible contents of a room or floor area expressed in terms of the average weight of combustible materials per unit area, from which the potential heat liberation may be calculated based on the calorific value of the materials, and includes the furnishings, finished floor, wall and ceiling finishes, trim and temporary and movable partitions.
Fire-protection rating means the time in minutes or hours that a closure will withstand the passage of flame when exposed to fire under specified conditions of test and performance criteria, or as otherwise prescribed in this Code.
Fire-resistance rating means the time in minutes or hours that a material or assembly of materials will withstand the passage of flame and the transmission of heat when exposed to fire under specified conditions of test and performance criteria, or as determined by extension or interpretation of information derived therefrom as prescribed in this Code. (See Sentence 1.2.1.(2) in MMAH Supplementary Standard SB-2)
Fire-retardant-treated wood means wood or a wood product that has had its surface-burning characteristics, such as flame spread, rate of fuel contribution and density of smoke developed, reduced by impregnation with fire-retardant chemicals.
Fire separation means a construction assembly that acts as a barrier against the spread of fire. (See Note A-1.4.1.2.(1))
Fire service main means a pipe and its appurtenances that are connected to a source of water and that are located on a property
(a) between the source of water and the base of the riser of a water-based fire protection system,
(b) between the source of water and inlets to foam making systems,
(c) between the source of water and the base elbow of private hydrants or monitor nozzles,
(d) as fire pump suction and discharge piping not within a building, or
(e) beginning at the inlet side of the check valve on a gravity or pressure tank.
Fire service pipe means a pipe that conveys water from a public water main or private water source to the inside of a building for the purpose of supplying the fire sprinkler or standpipe systems.
Firestop means a system consisting of a material, component and means of support used to fill gaps between fire separations or between fire separations and other assemblies, or used around items that wholly or partially penetrate a fire separation.
Fire stop flap means a device intended for use in horizontal assemblies required to have a fire-resistance rating and incorporating protective ceiling membranes that operates to close off a duct opening through the membrane in the event of a fire
Firewall means a type of fire separation of noncombustible construction that subdivides a building or separates adjoining buildings to resist the spread of fire and that has a fire-resistance rating as prescribed in this Code and has structural stability to remain intact under fire conditions for the required fire-rated time.
First storey means the storey that has its floor closest to grade and its ceiling more than 1.8 m above grade.
Fixture means a receptacle, appliance, apparatus or other device that discharges sewage or clear water waste, and includes a floor drain.
Fixture drain means the pipe that connects a trap serving a fixture to another part of a drainage system.
Fixture outlet pipe means a pipe that connects the waste opening of a fixture to the trap serving the fixture.
Fixture unit, as applying to a drainage system, means the unit of measure based on the rate of discharge, time of operation and frequency of use of a fixture that expresses the hydraulic load that is imposed by that fixture on the drainage system.
Fixture unit, as applying to water distribution systems, means the unit of measure based on the rate of supply, time of operation and frequency of use of a fixture or outlet that expresses the hydraulic load that is imposed by that fixture or outlet on the supply system.
Flame-spread rating means an index or classification indicating the extent of spread-of-flame on the surface of a material or an assembly of materials as determined in a standard fire test as prescribed in this Code.
Flammable liquid means a liquid having a flash point below 37.8°C and having a vapour pressure not more than 275.8 kPa (absolute) at 37.8°C as determined by ASTM D323, "Standard Test Method for Vapor Pressure of Petroleum Products (Reid Method)."
Flash point means the minimum temperature at which a liquid within a container gives off vapour in sufficient concentration to form an ignitable mixture with air near the surface of the liquid.
Flight means a series of steps between landings. (See Note A-1.4.1.2.(1))
Flood level rim means the top edge at which water can overflow from a fixture or device.
Floor area means the space on any storey of a building between exterior walls and required firewalls, including the space occupied by interior walls and partitions, but not including exits, vertical service spaces, and their enclosing assemblies.
Flow control roof drain means a roof drain that restricts the flow of storm water into the storm drainage system.
Flue means an enclosed passageway for conveying flue gases.
Flue collar means the portion of a fuel-fired appliance designed for the attachment of the flue pipe or breeching.
Flue pipe means the pipe connecting the flue collar of an appliance to a chimney.
Food premises means a floor area where food or drink for human consumption, or an ingredient of food or drink for human consumption, is manufactured, processed, prepared, stored, displayed, handled, served, distributed, sold or offered for sale, but does not include
(a) a private residence,
(b) a boarding house that provides meals for fewer than 10 boarders,
(c) a building to which Ontario Regulation 502/17 (Camps in Unorganized Territory) or Ontario Regulation 503/17 (Recreational Camps) made under the Health Protection and Promotion Act applies,
(d) a plant, as defined in the Milk Act, that is required to be operated under the authority of a licence issued under that Act,
(e) premises where a licensed activity, as defined in the Food Safety and Quality Act, 2001, is carried on by a person who is required to hold a licence issued under that Act,
(f) an egg-grading station or an egg-processing station, as defined in subsection 1(1) of Ontario Regulation 171/10 (Eggs and Processed Egg), made under the Food Safety and Quality Act, 2001,
(g) a floor area occupied by a church, service club or fraternal organization for the purpose of
(i)preparing meals for special events for its members and personally invited guests, or
(ii) conducting bake sales, or
(h) a farm building.
Forced-air furnace means a furnace equipped with a fan that provides the primary means for the circulation of air.
Force main means a sanitary drainage pipe through which sanitary sewage is conveyed by mechanical or pneumatic propulsion.
Foundation means a system or arrangement of foundation units through which the loads from a building are transferred to supporting soil or rock .
Foundation unit means one of the structural members of the foundation of a building such as a footing, raft or pile.
Fresh air inlet means a vent pipe that is installed in conjunction with a building trap and terminates outdoors.
Frost action means the phenomenon that occurs when
(a) water in soil is subjected to freezing which, because of the water ice phase change or ice lens growth, results in a total volume increase or the build-up of expansive forces under confined conditions or both, and
(b) the subsequent thawing leads to loss of soil strength and increased compressibility.
Functional statement means a function set out in Article 3.2.1.1. that a building or an element of a building is intended to perform.
Furnace means a space-heating appliance using warm air as the heating medium and usually having provision for the attachment of ducts.
Gaming premises means premises that are a gaming site as defined in the Ontario Lottery and Gaming Corporation Act, 1999.
Gas vent means that portion of a venting system designed to convey vent gases to the outdoors
(a) from the vent connector of a gas-fired appliance, or
(b) directly from the appliance when a vent connector is not used.
Grade means the average level of proposed or finished ground adjoining a building at all exterior walls.
Graded lumber means lumber that has been graded and stamped to indicate its grade, as determined by the NLGA, "Standard Grading Rules for Canadian Lumber".
Greenhouse agricultural occupancy (Group G, Division 3) means an agricultural building or part thereof that is primarily constructed of roofs and walls designed to transmit natural light.
Greywater means sanitary sewage of domestic origin that is derived from fixtures other than sanitary units.
Gross area means the total area of all floors above grade measured between the outside surfaces of exterior walls or between the outside surfaces of exterior walls and the centre line of firewalls, except that, in any occupancy other than a residential occupancy, where an access or a building service penetrates a firewall, measurements shall not be taken to the centre line of such firewall.
Ground water means, when applied to a sewage system, water below the surface of the ground that occupies a zone of the earth's mantle that is saturated with water.
Ground water table means, when applied to a sewage system, the elevation of the upper surface of the ground water existing in the area of the sewage system.
Groundwater means a free standing body of water in the ground.
Groundwater level (groundwater table) means the top surface of a free standing body of water in the ground.
Guard means a protective barrier, with or without openings through it, that is around openings in floors or at the open sides of stairs, landings, balconies, mezzanines, galleries, raised walkways or other locations to prevent accidental falls from one level to another.
Hauled sewage means sanitary sewage that
(a) is not finally disposed of at the site where it is produced and is not conveyed by a sewer to sewage works, and
(b) is stored or retained at the site where it is produced for periodic collection, handling, treatment, transportation, storage or processing prior to final disposal at a place other than where it was produced,
and includes sanitary sewage that is removed from a sewage system for the purpose of cleaning or maintaining the system.
Hauled sewage system means works, installations, equipment, operations and land used in connection with the collection, handling, treatment, transportation, storage, processing and disposal of hauled sewage, as regulated under the Environmental Protection Act.
Hazard index means a level on a scale of 1 to 8 determined in accordance with Tables 11.2.1.1.-B to 11.2.1.1.-N of Division B, designating the life safety hazard to occupants of a building based on
(a) use and occupancy,
(b) occupant load,
(c) the use and function of floor spaces,
(d) the difficulty of egress,
(e) the fire load of contents, finishes and furnishings,
(f) the configuration or compartmentation of floor spaces, and
(g) the size of the building,
and "H.I." has a corresponding meaning.
Hazardous classroom means a classroom
(a) that is supplied with flammable gas,
(b) that contains hazardous substances such as chemicals or explosive dusts,
(c) that contains large quantities of combustible materials, or
(d) where cooking equipment is used.
Hazardous extraction means a process to remove or separate a substance from a solution or mixture that involves the use of flammable liquids, combustible liquids or flammable gases as solvents in the process.
Hazardous room means a room containing sufficient quantities of a substance that, because of its chemical nature, may create an atmosphere or condition of imminent hazard to health.
Header means a vent pipe that connects two or more vent stacks or stack vents to open air.
Header line means a line of pipe with watertight joints installed in a sewage system for the purpose of distributing effluent from a treatment unit to the distribution pipe in a leaching bed.
Heat detector means a fire detector designed to operate at a predetermined temperature or rate of temperature rise.
Heavy timber construction means that type of combustible construction in which a degree of fire safety is attained
(a) by placing limitations on the sizes of wood structural members and on the thickness and composition of wood floors and roofs, and
(b) by the avoidance of concealed spaces under floors and roofs.
Heritage building means a building or part thereof,
(a) that is identified, or otherwise protected under the Ontario Heritage Act as being of cultural heritage value or interest:
(b) that has been set apart as a National Historic Site of Canada by the Minister of the Environment for Canada under the Canada National Parks Act (Canada):
(c) that has been marked or commemorated as a historic place having national historic interest or significance under the Historic Sites and Monuments Act (Canada); or
(d) that is listed on an inventory of property forming part of the cultural and natural heritage of a place inscribed on the United Nations Educational, Scientific and Cultural Organisation's World Heritage List of sites under the Convention Concerning the Protection of the World Cultural and Natural Heritage. (See Note A-1.4.1.2.(1))
High ground water table means the highest elevation at which there is physical evidence that the soil, as defined in Part 8 of Division B, or the leaching bed fill has been saturated with water.
High-hazard agricultural occupancy (Group G, Division 1) means an agricultural occupancy containing sufficient quantities of highly combustible and flammable or explosive materials which, because of their inherent characteristics, constitute a special fire hazard.
High-hazard industrial occupancy (Group F, Division 1) means an industrial occupancy containing sufficient quantities of highly combustible and flammable or explosive materials which, because of their inherent characteristics, constitute a special fire hazard.
Holding tank means a tank designed to totally retain all sanitary sewage discharged into it and requiring periodic emptying.
Home for special care means a home for the care of persons requiring nursing, residential or sheltered care.
Horizontal branch means that part of a waste pipe that is horizontal and installed to convey the discharge from more than one fixture.
Horizontal exit means an exit from one building to another by means of a doorway, vestibule, walkway, bridge or balcony.
Horizontal service space means a space such as an attic, duct, ceiling, roof or crawl space
(a) that is oriented essentially in a horizontal plane,
(b) that is concealed and generally inaccessible, and
(c) through which building service facilities such as pipes, ducts and wiring may pass.
Hotel means floor areas, a floor area or part of a floor area that contains four or more suites and that provides sleeping accommodation for the travelling public or for recreational purposes.
Hub drain means a drain opening for indirect liquid wastes
(a) that does not serve as a floor drain,
(b) that has the same pipe size, material and venting requirements as a floor drain,
(c) that has a flood level rim above the floor in which it is installed, and
(d) that receives wastes that are discharged directly into the drain opening.
Impeded egress zone means a supervised area in which occupants have free movement but require the release, by security personnel, of security doors at the boundary before they are able to leave the area, but does not include a contained use area.
Indirectly connected means not directly connected.
Indirect service water heater means a service water heater that derives its heat from a heating medium such as warm air, steam or hot water.
Individual vent means a vent pipe that serves one fixture.
Indoor pool means a public pool where the pool and pool deck are totally or partially covered by a roof.
Industrial occupancy (Group F) means the occupancy or use of a building or part thereof for the assembling, fabricating, manufacturing, processing, repairing or storing of goods and materials.
Interceptor means a receptacle that is designed and installed to prevent oil, grease, sand or other materials from passing into a drainage system.
Interconnected floor space means superimposed floor areas or parts of floor areas in which floor assemblies that are required to be fire separations are penetrated by openings that are not provided with closures.
Lake Simcoe shoreline has the same meaning as in the Lake Simcoe Protection Plan established under the Lake Simcoe Protection Act, 2008 and dated July, 2009.
Lake Simcoe watershed has the same meaning as in section 2 of the Lake Simcoe Protection Act, 2008.
Leaching means dispersal of liquid by downward or lateral drainage or both into permeable soil, as defined in Part 8 of Division B, or leaching bed fill.
Leaching bed means an absorption system constructed as absorption trenches or as a filter bed, located wholly in ground or raised or partly raised above ground, as required by local conditions, to which effluent from a treatment unit is applied for treatment and disposal and that is composed of
(a) the soil, as defined in Part 8 of Division B, leaching bed fill or other filter media that is contained between the surface on which the sanitary sewage is applied and the bottom of the bed,
(b) the leaching chamber or the distribution pipe and the stone or gravel layer in which the distribution pipe is located, and
(c) the backfill above the distribution pipe or the leaching chamber, including the topsoil and sodding or other anti erosion measure, and the side slopes of any portion elevated above the natural ground elevation.
Leaching bed fill means unconsolidated material suitable for the construction of a leaching bed, placed in the area of the leaching bed in order to obtain the required unsaturated zone below the distribution pipes or leaching chambers and the required lateral extent such that the effluent is absorbed.
Leaching chamber means a formed structure with an open bottom and permeable sidewalls installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.
Leader means a pipe that is installed to carry storm water from a roof to a storm building drain or sewer or other place of disposal.
Limiting distance means the distance from an exposing building face to a property line, the centre line of a street, lane or public thoroughfare, or to an imaginary line between 2 buildings or fire compartments on the same property, measured at right angles to the exposing building face.
Listed means equipment or materials included in a list published by a certification organization accredited by the Standards Council of Canada.
Liquid manure means manure having a dry matter content of less than 18 per cent or a slump of more than 150 millimetres using the Test Method for the Determination of Liquid Waste (slump test) set out in Schedule 9 to Regulation 347 of the Revised Regulations of Ontario, 1990 (General — Waste Management) made under the Environmental Protection Act.
Live load means a variable load due to the intended use and occupancy that is to be assumed in the design of the structural members of a building. It includes loads due to cranes and the pressure of liquids in containers.
Live/work unit means a dwelling units having an area of not more than 200 m² that contains a subsidiary business and personal services occupancy or a subsidiary low-hazard industrial occupancy, and which is used and operated by one or more persons of a single household.
Loadbearing (as applying to a building element) means subjected to or designed to carry loads in addition to its own dead load, excepting a wall element subjected only to wind or earthquake loads in addition to its own dead load.
Loading rate means the volume in litres of effluent per square metre applied in a single day to soil, as defined in Part 8 of Division B, or leaching bed fill.
Low-hazard industrial occupancy (Group F, Division 3) means an industrial occupancy in which the combustible content is not more than 50 kg/m² or 1,200 MJ/m² of floor area.
Low human occupancy means, when applied to a farm building, an occupancy in which the occupant load is not more than one person per 40 m² of floor area during normal use.
Major occupancy means the principal occupancy for which a building or part thereof is used or intended to be used, and shall be deemed to include the subsidiary occupancies that are an integral part of the principal occupancy. The major occupancy classifications used in this Code are as follows:
Group A, Division 1 – Assembly occupancies intended for the production and viewing of the performing arts
Group A, Division 2 – Assembly occupancies not elsewhere classified in Group A
Group A, Division 3 – Assembly occupancies of the arena type
Group A, Division 4 — Assembly occupancies in which the occupants are gathered in the open air
Group B, Division 1 – Detention occupancies in which persons are under restraint or are incapable of self-preservation because of security measures not under their control
Group B, Division 2 – Care and treatment occupancies
Group B, Division 3 – Care occupancies
Group C – Residential occupancies
Group D – Business and personal services occupancies
Group E – Mercantile occupancies
Group F, Division 1 – High-hazard industrial occupancies
Group F, Division 2 – Medium-hazard industrial occupancies
Group F, Division 3 – low-hazard industrial occupancies
Group G, Division 1 – High-hazard agricultural occupancies
Group G, Division 2 – Agricultural occupancies not elsewhere classified in Group G
Group G, Division 3 – Greenhouse agricultural occupancies
Group G, Division 4 – Agricultural occupancies with no human occupants
Make-up water means water added to a public pool from an external source.
Marquee means a canopy over an entrance to a building.
Masonry or concrete chimney means a chimney of brick, stone, concrete or masonry units constructed on site.
Means of egress means a continuous path of travel provided for the escape of persons from any point in a building or contained open space to a separate building, an open public thoroughfare, or an exterior open space protected from fire exposure from the building and having access to an open public thoroughfare. means of egress includes exits and access to exits.
Mechanically vented (as applying to a fuel-fired space- or water-heating appliance) means an appliance and its combustion venting system in which the products of combustion are entirely exhausted to the outdoors by a mechanical device, such as a fan, blower or aspirator, upstream or downstream from the combustion zone of the appliance, and the portion of the combustion venting system that is downstream of the fan, blower or aspirator is sealed and does not include draft hoods or draft control devices. (See Note A-1.4.1.2.(1))
Medium-hazard industrial occupancy (Group F, Division 2) means an industrial occupancy in which the combustible content is more than 50 kg/m² or 1,200 MJ/m² of floor areaand not classified as a high-hazard industrial occupancy.
Mercantile occupancy (Group E) means the occupancy or use of a building or part thereof for the displaying or selling of retail goods, wares or merchandise.
Mezzanine means an intermediate floor assembly between the floor and ceiling of any room or storey and includes an interior balcony.
Mobility assistive device means a mobility assistive device as defined in section 2 of Ontario Regulation 191/11 (Integrated Accessibility Standards) made under the Accessibility for Ontarians with Disabilities Act, 2005.
Modified pool means a public pool that has a basin-shaped floor sloping downward and inward toward the interior from the rim.
Modified stack venting means a stack venting arrangement in which the stack vent above the connection of the highest stack vented fixture is reduced in diameter.
Municipal drinking water system has the same meaning as in subsection 2(1) of the Safe Drinking Water Act, 2002.
Nominally horizontal means at an angle of less than 45° with the horizontal.
Nominally vertical means at an angle of not more than 45° with the vertical.
Nominal pipe size (NPS) means the nominal diameter by which a pipe, fitting, trap or other similar item is commercially designated.
Noncombustible means that a material meets the acceptance criteria of CAN/ULC-S114, "Standard Method of Test for Determination of Non-Combustibility in Building Materials."
Noncombustible construction means that type of construction in which a degree of fire safety is attained by the use of noncombustible materials for structural members and other building assemblies.
Objective means an objective set out in Article 2.2.1.1.
Occupancy means the use or intended use of a building or part thereof for the shelter or support of persons, animals or property.
Occupant load means the number of persons for which a building or part thereof is designed.
Offset means the piping that connects the ends of two pipes that are parallel.
Offset relief vent means a relief vent that provides additional air circulation upstream and downstream of an offset in a stack.
Open air means the atmosphere outside a building.
Open-air storey means a storey in which at least 25% of the total area of its perimeter walls is open to the outdoors in a manner that will provide cross-ventilation to the entire storey.
Outdoor pool means a public pool that is not an indoor pool.
Pail privy means a latrine in which the receptacle for human waste consists of a removable container surmounted by a superstructure.
Partition means an interior wall 1 storey or part-storey in height that is not loadbearing.
Party wall means a wall
(a) that is jointly owned and jointly used by two parties under an easement agreement or by a right in law, and
(b) that is erected at or upon a line separating two parcels of land each of which is, or is capable of being, a separate real estate entity.
Perched groundwater means a free standing body of water in the ground extending to a limited depth.
Percolation time means the average time in minutes that is required for water to drop one centimetre during a percolation test or as determined by a soil evaluation or analysis.
Performance level means the level of performance under which all or part of an existing building functions with respect to its building systems.
Permanent solid nutrient storage facility has the same meaning as in subsection 1(1) of Ontario Regulation 267/03 (General) made under the Nutrient Management Act, 2002.
Pharmacy means the premises in a building or the part of the premises in which prescriptions are compounded and dispensed for the public or in which drugs are sold by retail.
Pile means a slender deep foundation unit made of materials such as wood, steel or concrete or a combination thereof, that is either premanufactured and placed by driving, jacking, jetting or screwing, or cast-in-place in a hole formed by driving, excavating or boring. (Cast-in-place bored piles are often referred to as caissons in Canada.)
Plenum means a chamber forming part of an air duct system.
Plumbing appliance means a receptacle or equipment that receives or collects water, liquids or sewage and discharges water, liquid or sewage directly or indirectly to a plumbing system.
Plumbing system means a system of connected piping, fittings, valves, equipment, fixtures and appurtenances contained in plumbing.
Point of entry treatment unit has the same meaning as in subsection 1(1) of Ontario Regulation 170/03 (Drinking Water Systems) made under the Safe Drinking Water Act, 2002.
Pool deck means the area immediately surrounding a public pool.
Portable privy means a portable latrine in which the receptacle for human body waste and the superstructure are combined structurally into one unit.
Post-disaster building means a building that is necessary for the provision of essential services to the general public in the event of a disaster and includes
- hospitals, emergency treatment facilities and blood banks,
- telephone exchanges,
- power generating stations and electrical substations,
- control centres for natural gas distribution,
- control centres for air, land and marine transportation,
- water treatment facilities,
- water storage facilities,
- water and sewage pumping stations,
- sewage treatment facilities, and
- buildings of the following types, unless exempted from this designation by the principal authority:
- emergency response facilities,
- fire, rescue and police stations and housing for vehicles, aircraft or boats used for such purposes, and
- communications facilities, including radio and television stations. (See Note A-1.4.1.2.(1))
Potable means fit for human consumption.
Potable water system means the plumbing that conveys potable water.
Pressurized distribution system means a leaching bed in which the effluent is distributed through the use of pressurized distribution pipes.
Private sewage disposal system means a sewage system or a sewage works that is not owned and operated by the Crown, a municipality or an organization acceptable to the Director responsible for issuing an environmental compliance approval required under section 53 of the Ontario Water Resources Act.
Private sewer means a sewer other than a building sewer that
(a) is not owned or operated by a municipality, the Ministry of the Environment, Conservation and Parks or another public agency,
(b) receives drainage from more than one sanitary building drain either directly or through more than one sanitary building sewer or receives drainage from more than one storm building drain either directly or through one or more storm building sewers, and connects to a main sewer, or
(c) serves as a place of disposal on the property, but does not include
(d) a sewer that carries only the sanitary waste or storm sewage from semi-detached houses each containing not more than two dwelling units,
(e) a sewer that carries only the sanitary waste or storm sewage from one main building that is of care, care and treatment, detention, commercial or industrial occupancy and one ancillary building, or
(f) a sewer that carries only the sanitary waste or storm sewage from a row housing complex having five or fewer dwelling units.
Private use means, when applied to plumbing fixtures, fixtures in residences and apartments, in private bathrooms of hotels, and in similar installations in other buildings for a single household or an individual.
Private water supply means piping that serves as a source of supply on the property to more than one water service pipe.
Private water supply system means an assembly of pipes, fittings, valves, equipment and appurtenances that supplies water from a private source to a potable water system.
Privy vault means a latrine in which the receptacle for human waste consists of a constructed vault from which the waste is periodically removed.
Process plant means an industrial occupancy where materials, including flammable liquids, combustible liquids or gases, are produced or used in a process.
Professional engineer means a person who holds a licence or a temporary licence under the Professional Engineers Act.
Protected floor space means that part of a floor areaprotected from the effects of fire and used as part of a means of egress from an interconnected floor space.
Public corridor means a corridor that provides access to exit from more than one suite. (See Note A-1.4.1.2.(1))
Public heritage building means a heritage building where the occupancy in whole or in part includes viewing of the building by the public provided that displays in it are limited to those relevant to the heritage significance of the building.
Public pool means a structure, basin, chamber or tank containing or intended to contain an artificial body of water for swimming, water sport, water recreation or entertainment, but does not include
(a) pools operated in conjunction with less than six dwelling units, suites or single family residences or any combination of them,
(b) pools that are used only for commercial display and demonstration purposes,
(c) wading pools,
(d) hydro-massage pools, or
(e) pools that serve only as receiving basins for persons at the bottom of water slides.
Public spa means a hydro-massage pool that contains an artificial body of water, that is intended primarily for therapeutic or recreational use, that is not drained, cleaned or refilled before use by each individual and that utilizes hydrojet circulation, air induction bubbles, current flow or a combination of them over the majority of the pool area, but does not include
(a) wading pools, or
(b) spas operated in conjunction with less than six dwelling units, suites or single family residences, or any combination of them, for the use of occupants or residents and their visitors.
Public use means, when applied to plumbing fixtures, fixtures in general washrooms of schools, gymnasiums, hotels, bars, public comfort stations and other installations in which fixtures are installed so that their use is unrestricted.
Public way means a sidewalk, street, highway, square or other open space to which the public has access, as of right or by invitation, expressed or implied.
Rainwater means storm sewage runoff that is collected from a roof or the ground, but not from accessible patios and driveways.
Ramp means a path of travel having a slope steeper than 1 in 20.
Recirculation system means a system
(a) that maintains the circulation of water through a public pool by pumps, and
(b) that provides continuous treatment of the water, including filtration and chlorination or bromination and any other process that may be necessary for the treatment of the water.
Recreational camp means a camp for recreational activities consisting of one or more buildings or other structures established or maintained as living quarters, with or without charge, for the temporary occupancy of 10 or more persons for five or more days.
Relief vent means a vent pipe that is used in conjunction with a circuit vent to provide additional air circulation between a drainage system and a venting system.
Repair garage means a building or part thereof where facilities are provided for the repair or servicing of motor vehicles.
Residential full flow-through fire sprinkler/standpipe system means an assembly of pipes and fittings installed in the residential portions of a building containing one or two-family dwelling units that conveys water from the water service pipe to outlets in the sprinkler and standpipe systems and is fully integrated into the potable water system to ensure a regular flow of water through all parts of both systems.
Residential occupancy (Group C) means an occupancy in which sleeping accommodation is provided to residents who are not harboured for the purpose of receiving special care or treatment and are not involuntarily detained and includes an occupancy in which sleeping accommodation is provided to residents of a retirement home.
Residential partial flow-through sprinkler/standpipe system means an assembly of pipes and fittings installed in the residential portions of a building containing one or two family dwelling units that conveys water from the water service pipe to outlets in the sprinkler and standpipe systems and in which flow occurs during inactive periods of the sprinkler and standpipe systems only through the main header to the water closet located at the farthest point of the two systems.
Retirement home means a building or part of a building that is a retirement home as defined in subsection 2(1) of the Retirement Homes Act, 2010.
Return duct means a duct for conveying air from a space being heated, ventilated or air-conditioned back to the heating, ventilating or air-conditioning appliance.
Rim joist means the outermost member in floor framing, other than blocking, be it parallel, perpendicular or on an angle to the floor joists. (See Note A-1.4.1.2.(1))
Riser means a water distributing pipe that extends through at least one full storey, as defined in Part 7 of Division B.
Rock means that portion of the earth's crust that is consolidated, coherent and relatively hard and is a naturally formed, solidly bonded, mass of mineral matter that cannot readily be broken by hand.
Roof drain means a fitting or device that is installed in the roof to permit storm water to discharge into a leader.
Roof gutter means an exterior channel installed at the base of a sloped roof to convey storm water.
Run means the horizontal distance between two adjacent tread nosings on a stair. (See Figure A-9.8.4.-B in Note A-9.8.4. of Division B.)
Sanitary building drain means a building drain that conducts sewage to a building sewer from the most upstream stack, branch or fixture drain serving a water closet.
Sanitary building sewer means a pipe that is connected to a sanitary building drain 1,000 mm outside a wall of a building and that conducts sewage to a public sewer or private sewage disposal system.
Sanitary drainage pipe means all piping that conveys sanitary sewage to a place of disposal, including the sanitary building drain, sanitary building sewer, soil pipe, soil stack, waste stack and waste pipe but not the main sewer or piping in a sewage treatment plant.
Sanitary drainage system means a drainage system that conducts sewage.
Sanitary sewage means
(a) liquid or water borne waste
(i)of industrial or commercial origin, or
(ii)of domestic origin, including human body waste, toilet or other bathroom waste, and shower, tub, culinary, sink and laundry waste, or
(b) liquid or water borne waste discharged from a public pool to a drain.
Sanitary sewer means a sewer that conducts sewage.
Sanitary unit means a water closet, urinal, bidet or bedpan washer.
Secondary suite means a self-contained dwelling units located in a building or portion of a building of only residential occupancy that contains only one other dwelling units and common spaces, and where both dwelling units constitute a single real estate entity. (See Note A-1.4.1.2.(1))
Self-service storage building means a building that is used to provide individual storage spaces to the public and that is open to the public only for those purposes.
Septic tank means a watertight vault in which sanitary sewage is collected for the purpose of removing scum, grease and solids from the liquid without the addition of air and in which solids settling and anaerobic digestion of the sanitary sewage takes place.
Service room means a room provided in a building to contain equipment associated with building services. (See Note A-1.4.1.2.(1))
Service space means space provided in a building to facilitate or conceal the installation of building service facilities such as chutes, ducts, pipes, shafts or wires.
Service water heater means a device for heating water for plumbing services.
Sewage means sanitary sewage or storm sewage.
Sewage system means
(a) a chemical toilet, an incinerating toilet, a recirculating toilet, a self-contained portable toilet and all forms of privy, including a portable privy, an earth pit privy, a pail privy, a privy vault and a composting toilet system,
(b) a greywater system,
(c) a cesspool,
(d) a leaching bed system, or
(e) a system that requires or uses a holding tank for the retention of hauled sewage at the site where it is produced before its collection by a hauled sewage system , where these
(f) have a design capacity of 10,000 litres per day or less,
(g) have, in total, a design capacity of 10,000 litres per day or less, where more than one of these are located on a lot or parcel of land, and
(h) are located wholly within the boundaries of the lot or parcel of land on which is located the building or buildings they serve.
Sewage works means sewage works as defined in subsection 1(1) of the Ontario Water Resources Act.
Sewer lateral extension means the portion of a storm building sewer or sanitary building sewer that extends from the public sewer up to 1.5 m into the property.
Shallow buried trench means an absorption trench that contains a chamber or leaching chamber.
Shallow foundation means a foundation unit that derives its support from soil or rock located close to the lowest part of the building that it supports.
Shelf and rack storage system means a self-contained structural system within a building, having one or more elevated platforms or walkway levels for personnel access that may also support conveyors and other material handling, storage and distribution equipment.
Significant drinking water threat has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.
Size means the nominal diameter by which a pipe, fitting, trap or other similar item is commercially designated.
Smoke alarm means a combined smoke detector and audible alarm device designed to sound an alarm within the room or suite in which it is located upon the detection of smoke within that room or suite.
Smoke detector means a fire detector designed to operate when the concentration of airborne combustion products exceeds a predetermined level.
Soil means, except for the purposes of Part 8 of Division B, a portion of the earth’s crust that is fragmentary or such that individual particles of a dried sample may be readily separated by agitation in water, and includes boulders, cobbles, gravel, sand, silt, clay and organic matter.
Soil pipe means a sanitary drainage pipe that carries the discharge of a sanitary unit, with or without the discharge from any other fixture.
Soil stack means a vertical soil pipe that passes through one or more storeys and includes any offset that is part of the stack.
Solid masonry means a single wythe or multi-wythe construction made of solid masonry units or semi-solid, cored, or hollow masonry units, the cells of which may or may not be filled with mortar or grout. In multi-wythe masonry construction, the space between the wythes consists of a mortar-filled collar joint or grout-filled space and the wythes may or may not be constructed of the same masonry materials.
Solid masonry unit means a concrete block or brick unit, a clay brick unit, or a calcium silicate brick unit whose net solid area is at least 75% of its gross area. (See Note A-1.4.1.2.(1))
Sound transmission class (STC) means a single number rating of the airborne sound attenuation of a building assembly separating two adjoining spaces, taking into account the direct sound transmission path. (See Note A-1.4.1.2.(1)) (See also Note A-9.11. of Division B)
Source protection area has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.
Source protection plan has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.
Space heater means a space-heating appliance for heating the room or space within which it is located, without the use of ducts.
Space-heating appliance means an appliance intended for the supplying of heat to a room or space directly, such as a >unit heater, or to rooms or spaces of a building through a heating system such as a central furnace or boiler.
Sprinklered (as applying to a building or part thereof) means that the building or part thereof is equipped with a system of automatic sprinklers.
Stack vent means a vent pipe that connects the top of a soil stack or waste stack to a header or open air and “stack vented” has a corresponding meaning.
Stack venting means, when used with reference to fixtures, an arrangement such that the connections of the drainage piping from the stack vented fixtures to the stack provide venting to the fixture traps so that no additional vent pipe is required.
Stage means a space that is designed primarily for theatrical performances with provision for quick change scenery and overhead lighting, including environmental control for a wide range of lighting and sound effects and that is traditionally, but not necessarily, separated from the audience by a proscenium wall and curtain opening.
Starting platform means a rigid platform located entirely on a pool deck that consists of a top that, if projected horizontally over the water surface, would be less than 1,000 mm in vertical height above the surface and that is designed to be used by a swimmer to dive from at the start of a swimming race.
Storage garage means a building or part thereof intended for the storage or parking of motor vehicles and containing no provision for the repair or servicing of such vehicles. (See Note A-1.4.1.2.(1))
Storey means, except for the purposes of Part 7 of Division B, the portion of a building
(a) that is situated between the top of any floor and the top of the floor next above it, or
(b) that is situated between the top of the floor and the ceiling above the floor, if there is no floor above it.
Storm building drain means a building drain that conducts storm water and is connected at its upstream end to a leader, sump or catch basin, and at its downstream end to a building sewer or a designated storm water disposal location.
Storm building sewer means a building sewer that conveys storm sewage to a place of disposal and commences 1,000 mm from the building.
Storm drainage pipe means all the connected piping that conveys storm sewage to a place of disposal and includes the storm building drain, storm building sewer, rain water leader, catch basin and area drain installed to collect water from the property and the piping that drains water from a swimming pool, other than a public pool, or from water cooled air-conditioning equipment, but does not include
(a) a subsoil drainage pipe, or
(b) a private sewage treatment and disposal facility designed for the treatment or retention of storm sewage prior to discharge to the natural environment.
Storm drainage system means a drainage system that conveys storm sewage.
Storm sewage means water that is discharged from a surface as a result of rainfall, snow melt or snowfall.
Storm sewer means a sewer that conveys storm sewage.
Stove means an appliance intended for cooking or space heating or both.
Street means any highway, road, boulevard, square or other improved thoroughfare that is 9 m or more in width, that has been dedicated or deeded for public use and that is accessible to fire department vehicles and equipment.
subsoil drainage pipe means a pipe that is installed underground to intercept and convey subsurface water, and includes foundation drain pipes.
Subsurface investigation means the appraisal of the general subsurface conditions at a building site by analysis of information gained by such methods as geological surveys, in situ testing, sampling, visual inspection, laboratory testing of samples of the subsurface materials and groundwater observations and measurements.
Suite means a single room or series of rooms of complementary use, operated under a single tenancy, and includes
(a) dwelling units,
(b) individual guest rooms in motels, hotels, boarding houses, rooming houses and dormitories, and
(c) individual stores and individual or complementary rooms for business and personal services occupancies.
(See Note A-1.4.1.2.(1))
Supply duct means a duct for conveying air from a heating, ventilating or air-conditioning appliance to a space to be heated, ventilated or air-conditioned.
Surface water means water on the surface of the ground.
Tapered tread means a tread with non-parallel edges that increases or decreases its run uniformly over its width.
Tarion Warranty Corporation means Tarion Warranty Corporation as designated under section 2 of the Ontario New Home Warranties Plan Act.
Theatre means a place of public assembly intended for the production and viewing of the performing arts or the screening and viewing of motion pictures, and consisting of an auditorium with permanently fixed seats intended solely for a viewing audience.
Trap means a fitting or device that is designed to hold a liquid seal that will prevent the passage of gas but will not materially affect the flow of a liquid.
Trap arm means that portion of a fixture drain between the trap weir and the vent pipe fitting.
Trap dip means the lowest part of the upper interior surface of a trap.
Trap seal depth means the vertical distance between the trap dip and the trap weir.
Trap standard means the trap for a fixture that is integral with the support for the fixture.
Trap weir means the highest part of the lower interior surface of a trap.
Treatment unit means a device that, when designed, installed and operated in accordance with its design specifications, provides a specific degree of sanitary sewage treatment to reduce the contaminant load from that of sanitary sewage to a given effluent quality.
Tribunal means the Licence Appeal Tribunal established under the Licence Appeal Tribunal Act, 1999.
Type A dispersal bed means a leaching bed that receives effluent from a Level IV treatment unit as described in Table 8.6.2.2. of Division B and that is comprised of a stone layer or leaching chambers installed over an unsaturated sand layer as described in Subsection 8.7.7. of Division B.
Type B dispersal bed means a leaching bed comprised of a pressurized distribution system that uniformly distributes effluent from a Level IV treatment unit as described in Table 8.6.2.2. of Division B to the underlying soil, as defined in Part 8 of Division B, through a set of distribution pipes installed in a bed comprised of septic stone.
Underpinning means the process of strengthening the foundation or lowering the level of a foundation of an existing building.
Unit heater means a suspended space heater with an integral air-circulating fan.
Unprotected opening means, when applied to an exposing building face.
(a) a doorway, window or opening, other than one equipped with a closure having the required fire-protection rating, or
(b) any part of a wall forming part of the exposing building face that has a fire-resistance rating less than required for the exposing building face.
Unstable liquid means a liquid, including flammable liquids and combustible liquids, that is chemically reactive to the extent that it will vigorously react or decompose at or near normal temperature and pressure conditions or that is chemically unstable when subjected to impact.
Vacuum breaker means back-siphonage preventer.
Vapour barrier means the elements installed to control the diffusion of water vapour. (See Note A-1.4.1.2.(1))
Vent connector (as applying to heating or cooling systems) means the part of a venting system that conducts the flue gases or vent gases from the flue collar of a gas appliance to the chimney or gas vent, and may include a draft control device.
Vent pipe means a pipe that is part of a venting system.
Vent stack means a vent pipe that is connected at its upper end to a header or is terminated in open air and that is used to limit pressure differential in a soil or waste stack.
Venting system means an assembly of pipes and fittings that connects a drainage system with open air for circulation of air and the protection of trap seals in the drainage system.
Vertical leg means the vertical portion of a fixture drain and includes the portion of a drain from the outlet of a water closet bowl to the point where the connecting piping changes to horizontal.
Vertical service space means a shaft oriented essentially vertically that is provided in a building to facilitate the installation of building services including mechanical, electrical and plumbing installations and facilities such as elevators, refuse chutes and linen chutes.
Vulnerable area has the same meaning as in subsection 2(1) of the Clean Water Act, 2006.
Walkway means a covered or roofed pedestrian thoroughfare used to connect 2 or more buildings.
Waste pipe means a sanitary drainage pipe that carries the discharge from a fixture directly to a waste stack, soil stack, sanitary building drain, branch or sewage system .
Waste stack means a vertical waste pipe that passes through one or more storeys and includes any offset that is part of the stack that conducts liquid waste from fixtures other than sanitary units.
Water distribution system means an assembly of pipes, fittings, valves and appurtenances that conveys potable water to water supply outlets, fixtures, plumbing appliances and devices from the water service pipe or from a point of entry treatment unit located in the building.
Water purveyor means the owner or operator of a drinking water system.
Water service pipe means a pipe on the property that conveys potable water from a drinking water system or a private water supply to the inside of the building.
Water system means a water service pipe, a private water supply, a water distribution system, a fire service main or any part of any of them.
Wave action pool means a public pool equipped with a means for inducing wave motion in the water.
Wet vent means a waste pipe that also serves as a vent pipe.
Working capacity means the volume of liquid that a treatment unit or holding tank is capable of holding without overflowing while it is in its working position, but does not include the volume of liquid contained in a compartment in which a pump or siphon is installed.
X-ray equipment includes x-ray imaging systems, processing equipment and equipment directly related to the production of images for diagnosis or directly related to irradiation with x-rays for therapy.
X-ray machine means an electrically-powered device producing x-rays
(a) for the irradiation of a human being or an animal for a therapeutic or diagnostic purpose, or
(b) for industrial use.
Yoke vent means a vent pipe that is connected at its lower end to a soil or waste stack and at its upper end to a vent stack or a branch vent that is connected to a vent stack.
(2)Where a word or term that is defined in Sentence (1) is used, it shall be read as if it has the same meaning as in that Sentence, unless the context requires otherwise.
OBC Div. B 8.1.1.2. Definitions
Open OBC Div. B 8.1.1.2. in the code viewer(1)Except as provided in Sentence (2), words that appear in italics are defined in Article 1.4.1.2. of Division A and in the Building Code Act, 1992.
(2)In this Part,
Soil means in-situ, naturally occurring, unconsolidated mineral or organic material, at the earth's surface that is at least 100 mm thick and capable of supporting plant growth, and includes material compacted or cemented by soil forming processes, but does not include displaced materials such as gravel dumps, mine spoils, or like deposits.
OBC Div. A 1.4.1.1. Non-defined Terms
Open OBC Div. A 1.4.1.1. in the code viewer(1)Words and phrases used in this Code that are not included in the list of definitions in Articles 1.4.1.2., 1.4.1.3. and 1.4.1.4. and are not defined in another provision of this Code shall have the meanings that are commonly assigned to them in the context in which they are used, taking into account the specialized use of terms by the various trades and professions to which the terminology applies.
(2)Where objectives and functional statements are referred to in this Code, they shall be the objectives and functional statements described in Parts 2 and 3.
(3)Where acceptable solutions are referred to in this Code, they shall be the provisions stated in Parts 2 to 12 of Division B.
(4)Where alternative solutions are referred to in this Code, they shall be the alternative solutions mentioned in Clause 1.2.1.1.(1)(b).
OBC Div. A 1.4.1.2.(1) Effluent
Open OBC Div. A 1.4.1.2.(1) in the code viewerEffluent means sanitary sewage that has passed through a treatment unit.
OBC Div. A 1.4.1.2.(1) Greywater
Open OBC Div. A 1.4.1.2.(1) in the code viewerGreywater means sanitary sewage of domestic origin that is derived from fixtures other than sanitary units.
OBC Div. A 1.4.1.2.(1) Sanitary unit
Open OBC Div. A 1.4.1.2.(1) in the code viewerSanitary unit means a water closet, urinal, bidet or bedpan washer.
OBC Div. A 1.4.1.2.(1) Septic tank
Open OBC Div. A 1.4.1.2.(1) in the code viewerSeptic tank means a watertight vault in which sanitary sewage is collected for the purpose of removing scum, grease and solids from the liquid without the addition of air and in which solids settling and anaerobic digestion of the sanitary sewage takes place.
OBC Div. A 1.4.1.2.(1) Holding tank
Open OBC Div. A 1.4.1.2.(1) in the code viewerHolding tank means a tank designed to totally retain all sanitary sewage discharged into it and requiring periodic emptying.
OBC Div. A 1.4.1.2.(1) Treatment unit
Open OBC Div. A 1.4.1.2.(1) in the code viewerTreatment unit means a device that, when designed, installed and operated in accordance with its design specifications, provides a specific degree of sanitary sewage treatment to reduce the contaminant load from that of sanitary sewage to a given effluent quality.
OBC Div. A 1.4.1.2.(1) Percolation time
Open OBC Div. A 1.4.1.2.(1) in the code viewerPercolation time means the average time in minutes that is required for water to drop one centimetre during a percolation test or as determined by a soil evaluation or analysis.
OBC Div. A 1.4.1.2.(1) High ground water table
Open OBC Div. A 1.4.1.2.(1) in the code viewerHigh ground water table means the highest elevation at which there is physical evidence that the soil, as defined in Part 8 of Division B, or the leaching bed fill has been saturated with water.
OBC Div. A 1.4.1.2.(1) Leaching bed fill
Open OBC Div. A 1.4.1.2.(1) in the code viewerLeaching bed fill means unconsolidated material suitable for the construction of a leaching bed, placed in the area of the leaching bed in order to obtain the required unsaturated zone below the distribution pipes or leaching chambers and the required lateral extent such that the effluent is absorbed.
OBC Div. A 1.4.1.2.(1) Header line
Open OBC Div. A 1.4.1.2.(1) in the code viewerHeader line means a line of pipe with watertight joints installed in a sewage system for the purpose of distributing effluent from a treatment unit to the distribution pipe in a leaching bed.
OBC Div. A 1.4.1.2.(1) Distribution box
Open OBC Div. A 1.4.1.2.(1) in the code viewerDistribution box means a device for ensuring that effluent from a treatment unit is distributed in equal amounts to each line of distribution pipe or leaching chamber in a leaching bed.
OBC Div. A 1.4.1.2.(1) Shallow buried trench
Open OBC Div. A 1.4.1.2.(1) in the code viewerShallow buried trench means an absorption trench that contains a chamber or leaching chamber.
OBC Div. A 1.4.1.2.(1) Distribution pipe
Open OBC Div. A 1.4.1.2.(1) in the code viewerDistribution pipe means a line or lines of perforated or open jointed pipe or tile installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.
OBC Div. A 1.4.1.2.(1) Chamber
Open OBC Div. A 1.4.1.2.(1) in the code viewerChamber means a structure in a shallow buried trench that is constructed with an open bottom and that contains a pressurized distribution pipe.
OBC Div. A 1.4.1.2.(1) Leaching chamber
Open OBC Div. A 1.4.1.2.(1) in the code viewerLeaching chamber means a formed structure with an open bottom and permeable sidewalls installed in a leaching bed for the purpose of distributing effluent from a treatment unit to the soil, as defined in Part 8 of Division B, or leaching bed fill in the leaching bed.
OBC Div. A 1.4.1.2.(1) Ground water
Open OBC Div. A 1.4.1.2.(1) in the code viewerGround water means, when applied to a sewage system, water below the surface of the ground that occupies a zone of the earth's mantle that is saturated with water.
OBC Div. A 2.2.1.1. Objectives
Open OBC Div. A 2.2.1.1. in the code viewer(1)The objectives of this Code are as follows: (See Note A-2.2.1.1.(1))
OS Safety
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in or adjacent to the building will be exposed to an unacceptable risk of injury.
OS1 Fire Safety
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in or adjacent to the building will be exposed to an unacceptable risk of injury due to fire. The risks of injury due to fire addressed in this Code are those caused by—
OS1.1 – fire or explosion occurring
OS1.2 – fire or explosion impacting areas beyond its point of origin
OS1.3 – collapse of physical elements due to a fire or explosion
OS1.4 – fire safety systems failing to function as expected
OS1.5 – persons being delayed in or impeded from moving to a safe place during a fire emergency
OS2 Structural Safety
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in or adjacent to the building will be exposed to an unacceptable risk of injury due to structural failure. The risks of injury due to structural failure addressed in this Code are those caused by—
OS2.1 – loads bearing on the building elements that exceed their loadbearing capacity
OS2.2 – loads bearing on the building that exceed the loadbearing properties of the supporting medium
OS2.3 – damage to or deterioration of building elements
OS2.4 – vibration or deflection of building elements
OS2.5 – instability of the building or part thereof
OS2.6 – collapse of the excavation
OS3 Safety in Use
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in or adjacent to the building will be exposed to an unacceptable risk of injury due to hazards. The risks of injury due to hazards addressed in this Code are those caused by—
OS3.1 – tripping, slipping, falling, contact, drowning or collision
OS3.2 – contact with hot surfaces or substances
OS3.3 – contact with energized equipment
OS3.4 – exposure to hazardous substances
OS3.5 – exposure to high levels of sound from fire alarm systems
OS3.6 – persons becoming trapped in confined spaces
OS3.7 – persons being delayed in or impeded from moving to a safe place during an emergency (See Note A-2.2.1.1.(1))
OS4 Resistance to Unwanted Entry
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in the building will be exposed to an unacceptable risk of injury due to the building's low level of resistance to unwanted entry. The risks of injury due to unwanted entry addressed in this Code are those caused by—
OS4.1 – intruders being able to force their way through locked doors or windows
OS4.2 – occupants being unable to identify potential intruders as such
OH Health
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person will be exposed to an unacceptable risk of illness.
OH1 Indoor Conditions
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in the building will be exposed to an unacceptable risk of illness due to indoor conditions. The risks of illness due to indoor conditions addressed in this Code are those caused by—
OH1.1 – inadequate indoor air quality
OH1.2 – inadequate thermal comfort
OH1.3 – contact with moisture
OH2 Sanitation
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in the building will be exposed to an unacceptable risk of illness due to unsanitary conditions. The risks of illness due to unsanitary conditions addressed in this Code are those caused by—
OH2.1 – exposure to human or domestic waste
OH2.2 – consumption of contaminated water
OH2.3 – inadequate facilities for personal hygiene
OH2.4 – contact with contaminated surfaces
OH2.5 – contact with vermin and insects
OH2.6 – unsanitary conditions caused by exposure to human or domestic waste
OH3 Noise Protection
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in the building will be exposed to an unacceptable risk of illness due to high levels of sound originating in adjacent spaces in the building. The risks of illness due to high levels of sound addressed in this Code are those caused by—
OH3.1 – exposure to airborne sound transmitted through assemblies separating dwelling units from adjacent spaces in the building.
OH4 Vibration and Deflection Limitation
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in the building will be exposed to an unacceptable risk of illness due to high levels of vibration or deflection of building elements.
OH5 Hazardous Substances Containment
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, the public will be exposed to an unacceptable risk of illness due to the release of hazardous substances from the building.
OH6 Privacy
An objective of this Code is to limit the probability that, as a result of the design or construction of a building, a person in the building will be provided with an unacceptable level of privacy.
OH7 View to the Outdoors
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person in the building will be unable to experience a view to the outdoors.
OA Accessibility
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person with a physical or sensory limitation will be unacceptably impeded from accessing or using the building or its facilities.
OA1 Barrier-Free Path of Travel
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person with a physical or sensory limitation will be unacceptably impeded from accessing the building or circulating within it.
OA2 Barrier-Free Facilities
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, a person with a physical or sensory limitation will be unacceptably impeded from using the building's facilities.
OP Fire, Structural, Water and Sewage Protection of Buildings
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, the building or adjacent buildings will be exposed to an unacceptable risk of damage due to fire or structural insufficiency, or the building or part thereof will be exposed to an unacceptable risk of loss of use also due to structural insufficiency.
OP1 Fire Protection of the Building
An objective of this Code is to limit the probability that, as a result of its design or construction, the building will be exposed to an unacceptable risk of damage due to fire. The risks of damage due to fire addressed in this Code are those caused by—
OP1.1 – fire or explosion occurring
OP1.2 – fire or explosion impacting areas beyond its point of origin
OP1.3 – collapse of physical elements due to a fire or explosion
OP1.4 – fire safety systems failing to function as expected
OP2 Structural Sufficiency of the Building
An objective of this Code is to limit the probability that, as a result of its design or construction, the building or part thereof will be exposed to an unacceptable risk of damage or loss of use due to structural failure or lack of structural serviceability. The risks of damage and of loss of use due to structural failure or lack of structural serviceability addressed in this Code are those caused by—
OP2.1 – loads bearing on the building elements that exceed their loadbearing capacity
OP2.2 – loads bearing on the building that exceed the loadbearing properties of the supporting medium
OP2.3 – damage to or deterioration of building elements
OP2.4 – vibration or deflection of building elements
OP2.5 – instability of the building or part thereof
OP2.6 – instability or movement of the supporting medium
OP3 Protection of Adjacent Buildings from Fire
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, adjacent buildings will be exposed to an unacceptable risk of damage due to fire. The risks of damage to adjacent buildings due to fire addressed in this Code are those caused by—
OP3.1 – fire or explosion impacting areas beyond the building of origin
OP4 Protection of Adjacent Buildings from Structural Damage
An objective of this Code is to limit the probability that, as a result of the design or construction of the building, adjacent buildings will be exposed to an unacceptable risk of structural damage. The risks of structural damage to adjacent buildings addressed in this Code are those caused by—
OP4.1 – settlement of the medium supporting adjacent buildings
OP4.2 – collapse of the building or portion thereof onto adjacent buildings
OP4.3 – impact of the building on adjacent buildings
OP4.4 – collapse of the excavation
OP5 Water and Sewage Protection of Buildings and Facilities
An objective of this Code is to limit the probability that, as a result of the design or construction of a building, a building will be exposed to unacceptable risk of damage due to leakage of service water or sewage.
OR Resource Conservation
An objective of this Code is to limit the probability that, as a result of the design or construction of a building, a resource will be exposed to an unacceptable risk of depletion or the capacity of the infrastructure supporting the use, treatment or disposal of the resource will be exposed to an unacceptable risk of being exceeded.
OR1 Water and Energy Conservation
An objective of this Code is to limit the probability that, as a result of the design or construction of a building, a resource will be exposed to an unacceptable risk of depletion. The risks of resource depletion addressed in this Code are those caused by—
OR1.1 – the consumption of water
OR1.2 – the consumption of energy
OR2 Infrastructure Capacity
An objective of this Code is to limit the probability that, as a result of the design or construction of a building, the capacity of the infrastructure supporting the use, treatment or disposal of a resource will be exposed to an unacceptable risk of being exceeded. The risks of exceeding capacity addressed in this Code are those caused by—
OR2.1 – excessive demand on the infrastructure
OE Environmental Integrity
An objective of this Code is to limit the probability that, as a result of the design or construction or operation of the building, the natural environment will be exposed to an unacceptable risk of degradation.
OE1 Air Quality
An objective of this Code is to limit the probability that, as a result of the design or construction of a building, the natural environment will be exposed to an unacceptable risk of degradation due to emissions of greenhouse gases into the air. The risks of degradation addressed in this Code are those caused by—
OE1.1 – emissions of greenhouse gases into the air
OE1.2 – the release of contaminants, other than greenhouse gases, into the air
OE2 Water and Soil Quality
An objective of this Code is to limit the probability that, as a result of the design or construction of a building, the natural environment will be exposed to an unacceptable risk of degradation due to excessive release of contaminants into water or soil.
OC Conservation of Buildings
An objective of this Code is to limit the probability that, as a result of the extension, material alteration or repair of an existing building or a change in use of an existing building, the existing building cannot be acceptably conserved.
OBC Div. A 3.2.1.1. Functional Statements
Open OBC Div. A 3.2.1.1. in the code viewer(1)The objectives of this Code are achieved by measures, such as those described in the acceptable solutions in Division B, that are intended to allow the building or its elements to perform the following functions: (See Note A-3.2.1.1.(1))
F01 To minimize the risk of accidental ignition.
F02 To limit the severity and effects of fire or explosions.
F03 To retard the effects of fire on areas beyond its point of origin.
F04 To retard failure or collapse due to the effects of fire.
F05 To retard the effects of fire on emergency egress facilities.
F06 To retard the effects of fire on facilities for notification, suppression and emergency response.
F10 To facilitate the timely movement of persons to a safe place in an emergency.
F11 To notify persons, in a timely manner, of the need to take action in an emergency.
F12 To facilitate emergency response.
F13 To notify emergency responders, in a timely manner, of the need to take action in an emergency.
F20 To support and withstand expected loads and forces.
F21 To limit or accommodate dimensional change.
F22 To limit movement under expected loads and forces.
F23 To maintain equipment in place during structural movement.
F30 To minimize the risk of injury to persons as a result of tripping, slipping, falling, contact, drowning or collision.
F31 To minimize the risk of injury to persons as a result of contact with hot surfaces or substances.
F32 To minimize the risk of injury to persons as a result of contact with energized equipment.
F33 To limit the level of sound of a fire alarm system.
F34 To resist or discourage unwanted access or entry.
F35 To facilitate the identification of potential intruders.
F36 To minimize the risk that persons will be trapped in confined spaces.
F40 To limit the level of contaminants.
F41 To minimize the risk of generation of contaminants.
F42 To resist the entry of vermin and insects.
F43 To minimize the risk of release of hazardous substances.
F44 To limit the spread of hazardous substances beyond their point of release.
F45 To minimize the risk of the spread of diseases through communal shower facilities.
F46 To minimize the risk of contamination of potable water.
F50 To provide air suitable for breathing.
F51 To maintain appropriate air and surface temperatures.
F52 To maintain appropriate relative humidity.
F53 To maintain appropriate indoor/outdoor air pressure differences.
F54 To limit drafts.
F55 To resist the transfer of air through environmental separators.
F56 To limit the transmission of airborne sound into a dwelling unit from spaces elsewhere in the building.
F60 To control the accumulation and pressure of water on and in the ground.
F61 To resist the ingress of precipitation, water or moisture from the exterior or from the ground.
F62 To facilitate the dissipation of water and moisture from the building.
F63 To limit moisture condensation.
F70 To provide potable water.
F71 To provide facilities for personal hygiene.
F72 To provide facilities for the sanitary disposal of human and domestic wastes.
F73 To facilitate access to and circulation in the building and its facilities by persons with physical or sensory limitations.
F74 To facilitate the use of the building's facilities by persons with physical or sensory limitations.
F80 To resist deterioration resulting from expected service conditions.
F81 To minimize the risk of malfunction, interference, damage, tampering, lack of use or misuse.
F82 To minimize the risk of inadequate performance due to improper maintenance or lack of maintenance.
F101 To limit unwanted visual exposure.
F102 To provide a view to the outdoors in buildings.
F110 To control the release of contaminants into soil, groundwater, surface water, and air.
F111 To minimize the risk of malfunction, damage or failure of a sewage system.
F112 To provide adequate treatment of sanitary sewage and effluent.
F113 To minimize the risk of injury as a result of contact with sanitary sewage or partially treated effluent.
F120 To minimize the risk of injury to persons entering or exiting the pool, as a result of unfamiliarity with the pool.
F121 To minimize the risk of injury to persons using the pool, as a result of unfamiliarity with the pool.
F122 To minimize the risk of contamination of pool water.
F123 To facilitate timely response to incapacitated pool users.
F124 To minimize the risk of entrapment or injury to a person within the pool, as a result of water, air or vacuum action.
F130 To limit excessive water consumption.
F131 To limit excessive energy consumption.
F132 To limit excessive demand on the infrastructure.
F133 To limit excessive peak demand on the infrastructure.
F140 To facilitate the reuse and material alteration and repair of existing buildings.
F150 To limit excessive emissions of greenhouse gases into the air.
F151 To limit the excessive release of contaminants, other than greenhouse gases, into the air.
OBC Div. B 1.3.1.1. Effective Date
Open OBC Div. B 1.3.1.1. in the code viewer(1)Unless otherwise specified in this Code, the documents referenced in this Code shall include all amendments, revisions, reaffirmations, reapprovals, addenda and supplements effective to July 15, 2022.
OBC Div. B 1.3.1.2. Applicable Editions
Open OBC Div. B 1.3.1.2. in the code viewer(1)Where documents are referenced in this Code, they shall be in the editions designated in Table 1.3.1.2.
OBC Div. A 1.5.1.2. Conflicting Requirements
Open OBC Div. A 1.5.1.2. in the code viewer(1)In case of conflict between the provisions of this Code and those of a referenced document, the provisions of this Code shall govern.
OBC Div. B 8.6.2.1. Septic Tank Systems
Open OBC Div. B 8.6.2.1. in the code viewer(1)An effluent filter shall be installed in the outlet flow path of every septic tank that discharges effluent to a leaching bed.
(2)The septic tank effluent filter required by Sentence (1) shall,
(a)conform to the requirements of NSF/ANSI 46, "Evaluation of Components and Devices Used in Wastewater Treatment Systems,"
(b)be sized to filter particles of 1.6 mm,
(c)have a minimum area of 550 cm², and
(d)be installed in accordance with the manufacturer's recommendations.
(3)A secured access opening to allow for regular maintenance of the effluent filter shall be provided at the ground surface.
OBC Div. B Table 1.3.1.2. Documents Referenced in the Building Code — Forming Part of Sentence 1.3.1.2.(1)
Open OBC Div. B Table 1.3.1.2. in the code viewerTable 1.3.1.2. Documents Referenced in the Building Code — Forming Part of Sentence 1.3.1.2.(1) Issuing Agency | Document Number | Title of Document | Code Reference ACGIH | 2013, 28th Edition | Industrial Ventilation: A Manual of Recommended Practice for Design | 2.4.2.5.(1) 6.2.1.1.(1) 6.3.2.14.(2) ACI | 355.2-19 | Qualification of Post-Installed Mechanical Anchors in Concrete (ACI 355.2-19) and Commentary | 4.1.8.18.(7) ACI | 355.4 M-19 | Qualification of Post-Installed Adhesive Anchors in Concrete (ACI 355.4 M-19) and Commentary | 4.1.8.18.(7) AISI | S201-12 | North American Standard for Cold Formed Steel Framing – Product Data 2012 Edition | 9.24.1.2.(1) ANSI | A135.6-2012 | Engineered Wood Siding | Table 5.9.1.1. 9.27.9.1.(1) ANSI | A208.1-2016 | Particleboard | 9.23.15.2.(3) 9.29.9.1.(1) 9.30.2.2.(1) ANSI | E1.21-2013 | Entertainment Technology - Temporary Structures Used for Technical Production of Outdoor Entertainment Events | 3.17.2.8.(1) ANSI/ASHRAE | 62.1-2016 | Ventilation for Acceptable Indoor Air Quality | 6.3.1.1.(2) 6.3.1.1.(3) 6.3.2.2.(1) 6.3.2.10.(15) ANSI/CSA | ANSI Z21.22-2015 / CSA 4.4-2015 | Relief Valves for Hot Water Supply Systems | 7.2.10.11.(1) APA | ANSI/APA PRG 320- 2018 | Standard for Performance-Rated Cross-Laminated Timber | 3.1.6.3.(3) APHA/AWWA/ WEF | 2023, 24th Edition | Standard Methods for the Examination of Water and Wastewater | 8.9.2.4.(1) ASCE | ASCE/SEI 49-12 | Wind Tunnel Testing for Buildings and Other Structures | 4.1.7.14.(1) ASHRAE | 2021 | Fundamentals | 5.2.1.3.(1) 6.2.1.1.(1) 6.3.2.12.(1) 7.6.3.1.(2) 7.7.3.1.(1) 9.32.2.3.(4) 9.32.3.2.(1) 9.33.4.1.(1) 9.33.6.2.(8) 9.33.6.7.(2) ASHRAE | 2023 | HVAC Applications | 6.2.1.1.(1) 6.3.2.12.(1) 7.6.3.1.(2) 7.7.3.1.(1) 9.32.2.3.(4) 9.32.3.2.(1) 9.33.4.1.(1) 9.33.6.2.(8) 9.33.6.7.(2) ASHRAE | 2020 | HVAC Systems and Equipment | 6.2.1.1.(1) 6.3.2.12.(1) 7.6.3.1.(2) 7.7.3.1.(1) 9.32.2.3.(4) 9.32.3.2.(1) 9.33.4.1.(1) 9.33.6.2.(8) 9.33.6.7.(2) ASHRAE | 2022 | Refrigeration | 6.2.1.1.(1) 6.3.2.12.(1) 7.6.3.1.(2) 7.7.3.1.(1) 9.32.2.3.(4) 9.32.3.2.(1) 9.33.4.1.(1) 9.33.6.2.(8) 9.33.6.7.(2) ASHRAE | Guideline 12-2000 | Minimizing the Risk of Legionellosis Associated with Building Water Systems | 6.2.1.1.(1) 6.3.2.15.(9) 6.3.2.16.(1) ASME | A112.19.8-2007 | Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs | 3.12.4.1.(9) ASME | B16.3-2021 | Malleable Iron Threaded Fittings: Classes 150 and 300 | 7.2.6.6.(1) ASME | B16.4-2021 | Gray Iron Threaded Fittings: Classes 125 and 250 | 7.2.6.5.(1) Table 7.2.11.2. ASME | B16.5-2020 | Pipe Flanges and Flanged Fittings: NPS ½ through NPS 24 Metric/Inch Standard | 7.2.6.12.(1) ASME | B16.9-2018 | Factory-Made Wrought Buttwelding Fittings | 7.2.6.11.(1) 7.2.6.14.(1) ASME | B16.12-2019 | Cast Iron Threaded Drainage Fittings | 7.2.6.3.(1) ASME | B16.15-2018 | Cast Copper Alloy Threaded Fittings: Classes 125 and 250 | 7.2.7.3.(1) ASME | B16.18-2021 | Cast Copper Alloy Solder Joint Pressure Fittings | 7.2.7.6.(1) 7.2.7.6.(2) Table 7.2.11.2. ASME | B16.22-2021 | Wrought Copper and Copper Alloy Solder Joint Pressure Fittings | 7.2.7.6.(1) Table 7.2.11.2. ASME | B16.23-2016 | Cast Copper Alloy Solder Joint Drainage Fittings: DWV | 7.2.7.5.(1) ASME | B16.24-2016 | Cast Copper Alloy Pipe Flanges and Flanged Fittings: Classes 150, 300, 600, 900, 1500 and 2500 | 7.2.7.2.(1) ASME | B16.26-2018 | Cast Copper Alloy Fittings for Flared Copper Tubes | 7.2.7.7.(1) 7.2.7.7.(2) Table 7.2.11.2. ASME | B16.29-2017 | Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings - DWV | 7.2.7.5.(1) ASME | ANSI/ASME B18.6.1- 1981 | Wood Screws (Inch Series) | Table 5.9.1.1. ASME | B31.9-2020 | Building Services Piping | 7.3.2.8.(1) ASME | B36.19 M-2018 | Stainless Steel Pipe | 7.2.6.10.(1) ASME/CSA | ASME A17.1-2016 / CSA B44-16 | Safety Code for Elevators and Escalators | 3.5.2.2.(1) Table 4.1.5.11. Table 4.1.8.18. 7.4.3.6.(1) ASME/CSA | ASME A112.3.4-2018 / CSA B45.9-18 | Macerating Toilet Systems and Waste-Pumping Systems for Plumbing Fixtures | 7.2.2.2.(1) ASME/CSA | ASME A112.4.2-2021/CSA B45.16-21 | Personal hygiene devices for water closets | 7.2.2.2.(1) ASME/CSA | ASME A112.4.14- 2017/CSA B125.14-17 | Manually Operated Valves for Use in Plumbing Systems | 7.2.10.6.(7) ASME/CSA | ASME A112.18.1-2018 / CSA B125.1-18 | Plumbing Supply Fittings | 7.2.10.6.(1) 7.2.10.7.(1) 7.2.10.7B.(1) ASME/CSA | ASME A112.18.2-2020 / CSA B125.2-20 | Plumbing Waste Fittings | 7.2.3.3.(1) 7.2.10.6.(6) ASME/CSA | ASME A112.18.6- 2017/CSA B125.6-17 | Flexible water connectors | 7.2.10.18.(1) ASME/CSA | ASME A112.19.1-2018 / CSA B45.2-18 | Enamelled Cast Iron and Enamelled Steel Plumbing Fixtures | 7.2.2.2.(1) ASME/CSA | ASME A112.19.2-2018 / CSA B45.1-18 | Ceramic Plumbing Fixtures | 7.2.2.2.(1) ASME/CSA | ASME A112.19.3-2017 / CSA B45.4-17 | Stainless Steel Plumbing Fixtures | 7.2.2.2.(1) ASME/CSA | ASME A112.19.7-2020 / CSA B45.10-20 | Hydromassage Bathtub Systems | 7.2.2.2.(1) ASPE | ASPE Plumbing Engineering Design Handbook - Volume 1 2021 | Fundamentals of Plumbing Engineering | 7.6.3.1.(2) 7.7.3.1.(1) ASPE | ASPE Plumbing Engineering Design Handbook - Volume 2 2022 | Plumbing Systems | 7.6.3.1.(2) 7.7.3.1.(1) ASPE | ASPE Plumbing Engineering Design Handbook -Volume 3 2023 | Special Plumbing Systems | 7.6.3.1.(2) 7.7.3.1.(1) ASPE | ASPE Plumbing Engineering Design Handbook - Volume 4 2020 | Plumbing Components and Equipment | 7.6.3.1.(2) 7.7.3.1.(1) ASSE | ANSI/ASSE 1010-2021 | Water Hammer Arresters | 7.2.10.15.(1) ASSE | 1051-2021 | Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems | 7.2.10.16.(1) ASSE/ASME/CSA | ASSE 1002-2020/ASME A112.1002-2020/CSA B125.12-20 | Anti-siphon fill valves for water closet tanks | 7.2.10.10.(2) ASSE/ASME/CSA | ASSE 1016-2017/ASME A112.1016-2017/CSA B125.16-17 | Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations | 7.2.10.7.(1) ASSE/ASME/CSA | ASSE 1037-2020/ASME A112.1037-2020/CSA B125.37-20 | Performance requirements for pressurized flushing devices for plumbing fixtures | 7.2.10.8.(1) ASSE/ASME/CSA | ASSE 1070-2020/ASME A112.1070-2020/CSA B125.70-20 | Performance requirements for water temperature limiting devices | 7.2.10.7.(2) ASTM | A53 / A53M-20 | Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc- Coated Welded and Seamless | 7.2.6.7.(4) ASTM | A123 / A123 M-17 | Standard Specification for Zinc (Hot Dip Galvanized) Coatings on Iron and Steel Products | Table 5.9.1.1. Table 9.20.16.1. ASTM | A153 / A153 M-16a | Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware | Table 5.9.1.1. Table 9.20.16.1. 9.23.2.4.(2) ASTM | A182 / A182M-21 | Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, and Valves and Parts for High- Temperature Service | 7.2.6.12.(1) 7.2.6.13.(1) ASTM | A252/A252M-19 | Standard Specification for Welded and Seamless Steel Pipe Piles | 4.2.3.8.(1) ASTM | A269/A269M-15a | Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service | 7.2.6.14.(1) ASTM | A283 / A283 M-18 | Standard Specification for Low and Intermediate Tensile Strength Carbon Steel Plates | 4.2.3.8.(1) ASTM | A312 / A312M-22 | Standard Specification for Seamless, Welded, and Heavily Cold Worked Stainless Steel Pipes | 7.2.6.10.(1) ASTM | A351 / A351M-18e1 | Standard Specification for Castings, Austenitic, for Pressure-Containing Parts | 7.2.6.13.(1) ASTM | A403 / A403M-22 | Standard Specification for Wrought Austenitic Stainless Steel Piping Fittings | 7.2.6.11.(1) ASTM | A518 / A518 M-99 | Standard Specification for Corrosion-Resistant High-Silicon Iron Castings | 7.2.8.1.(1) ASTM | A653 / A653M-20 | Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process | Table 5.9.1.1. 9.3.3.2.(1) 9.23.2.4.(1) ASTM | A792 / A792M-21a | Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy- Coated by the Hot-Dip Process | 9.3.3.2.(1) ASTM | A1008 / A1008M-21a | Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable | 4.2.3.8.(1) ASTM | A1011 / A1011 M-18a | Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength | 4.2.3.8.(1) ASTM | B32-20 | Standard Specification for Solder Metal | 7.2.9.2.(1) ASTM | B42-20 | Standard Specification for Seamless Copper Pipe, Standard Sizes | 7.2.7.1.(1) ASTM | B43-20 | Standard Specification for Seamless Red Brass Pipe, Standard Sizes | 7.2.7.1.(2) ASTM | B68 / B68 M-19 | Standard Specification for Seamless Copper Tube, Bright Annealed | 7.2.7.4.(4) ASTM | B88-20 | Standard Specification for Seamless Copper Water Tube | 7.2.7.4.(1) 7.2.7.4.(4) Table 7.2.11.2. ASTM | B306-20 | Standard Specification for Copper Drainage Tube (DWV) | 7.2.7.4.(1) ASTM | B813-16 | Standard Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube | 7.2.9.2.(3) ASTM | B828-16 | Standard Specification for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings | 7.3.2.4.(1) ASTM | C4-04 | Standard Specification for Clay Drain Tile and Perforated Clay Drain Tile | Table 5.9.1.1. 9.14.3.1.(1) ASTM | C27-98 | Standard Specification for Fireclay and High-Alumina Refractory Brick | 9.21.3.4.(1) ASTM | C73-17 | Standard Specification for Calcium Silicate Brick (Sand-Lime Brick) | Table 5.9.1.1. 9.20.2.1.(1) ASTM | C126-22 | Standard Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units | Table 5.9.1.1. 9.20.2.1.(1) ASTM | C212-22 | Standard Specification for Structural Clay Facing Tile | Table 5.9.1.1. 9.20.2.1.(1) ASTM | C260 / C260 M-10a | Standard Specification for Air-Entraining Admixtures for Concrete | 9.3.1.8.(1) ASTM | C411-19 | Standard Specification for Hot-Surface Performance of High- Temperature Thermal Insulation | 3.6.5.4.(4) 3.6.5.5.(1) 9.33.8.2.(2) ASTM | C412M-19 | Standard Specification for Concrete Drain Tile | Table 5.9.1.1. 9.14.3.1.(1) ASTM | C444M-21 | Standard Specification for Perforated Concrete Pipe | Table 5.9.1.1. 9.14.3.1.(1) ASTM | C494 / C494M-19 | Standard Specification for Chemical Admixtures for Concrete | 9.3.1.8.(1) ASTM | C553-13 | Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications | Table 5.9.1.1. ASTM | C612-14 | Standard Specification for Mineral Fiber Block and Board Thermal Insulation | Table 5.9.1.1. ASTM | C700-18 | Standard Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength and Perforated | Table 5.9.1.1. 9.14.3.1.(1) ASTM | C726-17 | Standard Specification for Mineral Wool Roof Insulation Board | Table 5.9.1.1. 9.25.2.2.(1) ASTM | C834-17 | Standard Specification for Latex Sealants | Table 5.9.1.1. 9.27.4.2.(2) ASTM | C840-20 | Standard Specification for Application and Finishing of Gypsum Board | 3.1.6.6.(6) Table 5.9.1.1. 9.29.5.1.(3) ASTM | C920-18 | Standard Specification for Elastomeric Joint Sealants | Table 5.9.1.1. 9.27.4.2.(2) ASTM | C954-22 | Standard Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness | 9.24.1.4.(1) ASTM | C991-16 | Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings | Table 5.9.1.1. ASTM | C1002-22 | Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs | Table 5.9.1.1. 9.24.1.4.(1) 9.29.5.7.(1) ASTM | C1053-00 | Standard Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste and Vent (DWV) Applications | 7.2.8.1.(1) ASTM | C1177 / C1177 M-17 | Standard Specification for Glass Mat Gypsum Substrate for Use as Sheathing | 3.1.5.14.(6) 3.1.5.15.(4) Table 5.9.1.1. Table 9.23.17.2-A ASTM | C1178 / C1178 M-18 | Standard Specification for Coated Glass Mat Water-Resistant Gypsum Backing Panel | 3.1.5.14.(6) 3.1.5.15.(4) Table 5.9.1.1. 9.29.5.2.(1) ASTM | C1184-18e1 | Standard Specification for Structural Silicone Sealants | Table 5.9.1.1. 9.27.4.2.(2) ASTM | C1280-18 | Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing | Table 5.9.1.1. ASTM | C1311-22 | Standard Specification for Solvent Release Sealants | Table 5.9.1.1. 9.27.4.2.(2) ASTM | C1330-18 | Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid-Applied Sealants | Table 5.9.1.1. 9.27.4.2.(3) ASTM | C1396 / C1396 M-17 | Standard Specification for Gypsum Board | 3.1.5.14.(6) 3.1.5.15.(4) 3.1.6.6.(2) 3.1.6.6.(3) 3.1.6.6.(4) 3.1.6.6.(5) 3.1.6.15.(1) Table 5.9.1.1. Table 9.23.17.2.-A 9.29.5.2.(1) Table 9.29.5.3. ASTM | C1658 / C1658M-19e1 | Standard Specification for Glass Mat Gypsum Panels | 3.1.5.14.(6) Table 5.9.1.1. ASTM | D323-20a | Standard Specification for Vapor Pressure of Petroleum Products (Reid Method) | 1.4.1.2.(1) of Division A ASTM | D374-99 / D374 M-16 | Standard Test Methods for Thickness of Solid Electrical Insulation | 3.15.4.1.(1) ASTM | D635-22 | Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position | 3.15.4.1.(1) ASTM | D1227 / D1227M-13e1 | Standard Specification for Emulsified Asphalt Used as a Protective Coating for Roofing | Table 5.9.1.1. 9.13.2.2.(2) 9.13.3.2.(2) ASTM | D2178 / D2178M-15a | Standard Specification for Asphalt Glass Felt Used in Roofing and Waterproofing | Table 5.9.1.1. ASTM | D2466-21 | Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 | 7.2.5.7.(2) ASTM | D2467-20 | Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 | 7.2.5.7.(2) ASTM | D2898-10 | Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing | 3.1.4.8.(3) 3.1.5.5.(3) 3.1.5.24.(1) 3.1.6.9.(8) 3.2.3.7.(4) ASTM | D3019 / D3019 M-17 | Standard Specification for Lap Cement Used with Asphalt Roll Roofing, Non-Fibered, Asbestos-Fibered, and Non-Asbestos-Fibered | Table 5.9.1.1. 9.13.3.2.(2) Table 9.27.2.1.-B ASTM | D3261-16 | Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing | 7.2.5.4.(3) ASTM | D3679-21 | Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding | 9.27.12.1.(1) ASTM | D3801-20a | Standard Test Method for Measuring the Comparative Burning Characteristics of Solid Plastics in a Vertical Position | 3.15.4.1.(1) ASTM | D4477-22 | Standard Specification for Rigid (Unplasticized) Poly(Vinyl Chloride) (PVC) Soffit | 9.27.12.1.(3) ASTM | D4479 / D4479M-07 | Standard Specification for Asphalt Roof Coatings - Asbestos-Free | Table 5.9.1.1. 9.13.2.2.(2) 9.13.3.2.(2) Table 9.26.2.1.-B ASTM | D4637 / D4637 M-15 | Standard Specification for EPDM Sheet Used In Single-Ply Roof Membrane | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B ASTM | D4811 / D4811 M-16 | Standard Specification for Nonvulcanized (Uncured) Rubber Sheet Used as Roof Flashing | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B ASTM | D5456-21e1 | Standard Specification for Evaluation of Structural Composite Lumber Products | 3.1.11.7.(5) ASTM | D6878 / D6878M-21 | Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B ASTM | D7254-21 | Standard Specification for Polypropylene (PP) Siding | 9.27.13.1.(1) ASTM | D7793-21 | Standard Specification for Insulated Vinyl Siding | 9.27.12.1.(2) ASTM | E90-09 | Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements | 5.8.1.2.(1) 5.8.1.4.(1) 9.11.1.2.(1) ASTM | E96 / E96M-22 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | 5.5.1.2.(3) 9.13.2.2.(2) 9.25.4.2.(1) 9.25.4.2.(2) 9.25.5.1.(1) ASTM | E283/E283M-19 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | 5.9.3.4.(2) ASTM | E331-00 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | 5.9.3.5.(2) ASTM | E336-20 | Standard Test Method for Measurement of Airborne Sound Attenuation Between Rooms in Buildings | 5.8.1.2.(2) 5.8.1.4.(7) 9.11.1.2.(2) ASTM | E413-22 | Classification for Rating Sound Insulation | 5.8.1.2.(1) 5.8.1.2.(2) 5.8.1.4.(7) 5.8.1.5.(3) 9.11.1.2.(1) 9.11.1.2.(2) ASTM | E547-00 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference | 5.9.3.5.(2) ASTM | E130016 | Standard Practice for Determining Load Resistance of Glass in Buildings | 4.3.6.1.(1) ASTM | E2190-19 | Standard Specification for Insulating Glass Unit Performance and Evaluation | Table 5.9.1.1. 9.6.1.2.(1) ASTM | E2307-20 | Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-storey Test Apparatus | 3.1.8.3.(4) 9.10.9.2.(4) ASTM | F476-14 | Standard Test Methods for Security of Swinging Door Assemblies | 9.7.5.2.(2) ASTM | F628-22 | Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe With a Cellular Core | 7.2.5.9.(1) 7.2.5.11.(1) 7.2.5.11.(1.1) ASTM | F714-22 | Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Outside Diameter | 7.2.5.5.(1) ASTM | F1667/F1667M-21a | Standard Specification for Driven Fasteners: Nails, Spikes and Staples | 9.23.3.1.(1) 9.26.2.3.(1) 9.29.5.6.(1) ASTM | F3128-19 | Standard Specification for Poly(Vinyl Chloride) (PVC) Schedule 40 Drain, Waste, and Vent Pipe with a Cellular Core | 7.2.5.16.(1) AWS | ANSI/AWS A5.8 M / A5.8: 2011 | Specification for Filler Metals for Brazing and Braze Welding | 7.2.9.2.(4) AWWA | ANSI/AWWA C104 / A21.4-13 | Cement-Mortar Lining for Ductile-Iron Pipe and Fittings | 7.2.6.4.(2) Table 7.2.11.2. AWWA | ANSI/AWWA C110 / A21.10-12 | Ductile-Iron and Gray-Iron Fittings | 7.2.6.4.(3) Table 7.2.11.2. AWWA | ANSI/AWWA C111 / A21.11-12 | Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings | 7.2.6.4.(4) Table 7.2.11.2. AWWA | ANSI/AWWA C151 / A21.51-09 | Ductile-Iron Pipe, Centrifugally Cast | 7.2.6.4.(1) Table 7.2.11.2. AWWA | ANSI/AWWA C228-08 | Stainless-Steel Pipe Flanges For Water Service - Sizes 2 in. through 72 in. (50 mm through 1,800 mm) | 7.2.6.12.(1) BCMOH | Version 2, 21st Sept, 2007 | Sewerage System Standard Practice Manual | 8.7.8.3.(2) 8.7.8.3.(3) BNQ | BNQ 3624-115-2016 | Polyethylene (PE) Pipe and Fittings - Flexible Pipes for Drainage - Characteristics and Test Methods | Table 5.9.1.1. 9.14.3.1.(1) BNQ | CAN/BNQ 3680-600- 2023 | Onsite Residential Wastewater Treatment Technologies | 8.6.2.2.(5) Table 8.6.2.2. CCBFC | NRCC 38726 1995 | National Building Code of Canada | 2.1.2.3.(3) 2.1.2.3.(5) CCBFC | NRCC 38732 1995 | National Farm Building Code of Canada | 2.1.2.3.(1) 2.1.2.3.(2) 2.1.2.3.(3) 2.1.2.3.(5) CCBFC | NRCC-CONST-56435E 2020 | National Building Code of Canada | 2.4.2.1.(2) of Division C CCBFC | NRCC-CONST-56436E 2020 | National Plumbing Code of Canada | 2.4.2.1.(2) of Division C CCBFC | NRCC-CONST-56437E 2020 | National Fire Code of Canada | 1.4.1.2.(1) of Division A 2.2.6.11.(1) 2.2.8.1.(1) 2.2.8.1.(4) 2.2.8.7.(1) 2.4.2.3.(4) 3.1.13.1.(1) 3.3.1.2.(1) 3.3.5.2.(1) 3.7.5.2.(1) 6.9.1.2.(1) CGSB | CAN/CGSB-1.501-M89 | Method of Permeance of Coated Wallboard | 5.5.1.2.(2) 9.25.4.2.(7) CGSB | CAN/CGSB-7.2-94 | Adjustable Steel Columns | 9.17.3.4.(1) CGSB | CAN/CGSB-10.3-92 | Air Setting Refractory Mortar | 9.21.3.4.(2) 9.21.3.9.(1) 9.22.2.2.(2) CGSB | CAN/CGSB-11.3-M87 | Hardboard | Table 5.9.1.1. 9.29.7.1.(1) 9.30.2.2.(1) CGSB | CAN/CGSB-12.1-2022 | Safety Glazing | 3.3.1.20.(3) 3.3.2.17.(1) 3.3.2.17.(2) 3.4.6.15.(1) 3.4.6.15.(3) 3.7.4.10.(1) Table 5.9.1.1. 9.6.1.2.(1) 9.6.1.4.(1) 9.6.1.4.(6) 9.8.8.7.(1) CGSB | CAN/CGSB-12.2-M91 | Flat, Clear Sheet Glass | Table 5.9.1.1. 9.6.1.2.(1) CGSB | CAN/CGSB-12.3-M91 | Flat, Clear Float Glass | Table 5.9.1.1. 9.6.1.2.(1) CGSB | CAN/CGSB-12.4-M91 | Heat Absorbing Glass | Table 5.9.1.1. 9.6.1.2.(1) CGSB | CAN/CGSB-12.5-M86 | Mirrors, Silvered | 9.6.1.2.(3) CGSB | CAN/CGSB-12.8-2017 | Insulating Glass Units | Table 5.9.1.1. 9.6.1.2.(1) CGSB | CAN/CGSB-12.9-M91 | Spandrel Glass | Table 5.9.1.1. 9.6.1.2.(1) CGSB | CAN/CGSB-12.10-M76 | Glass, Light and Heat Reflecting | 9.6.1.2.(1) CGSB | CAN/CGSB-12.11-M90 | Wired Safety Glass | 3.3.1.20.(3) 3.4.6.15.(1) 3.4.6.15.(3) 9.6.1.2.(1) 9.6.1.4.(1) 9.8.8.7.(1) CGSB | CAN/CGSB-12.20-M89 | Structural Design of Glass for Buildings | 4.3.6.1.(1) CGSB | CAN/CGSB-19.22-M89 | Mildew Resistant Sealing Compound for Tubs and Tiles | 9.29.10.5.(1) CGSB | 37-GP-9Ma-1983 | Primer, Asphalt, Unfilled, for Asphalt Roofing, Dampproofing and Waterproofing | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-A CGSB | CAN/CGSB-37.50-M89 | Hot-Applied, Rubberized Asphalt for Roofing and Waterproofing | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B CGSB | CAN/CGSB-37.51-M90 | Application for Hot-Applied Rubberized Asphalt for Roofing and Waterproofing | 9.26.15.1.(1) CGSB | CAN/CGSB-37.54-95 | Polyvinyl Chloride Roofing and Waterproofing Membrane | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B CGSB | 37-GP-55 M-1979 | Application of Sheet Applied Flexible Polyvinyl Chloride Roofing Membrane | 9.26.16.1.(1) CGSB | 37-GP-56 M-1985 | Membrane, Modified, Bituminous, Prefabricated, and Reinforced for Roofing | 9.13.3.2.(2) Table 9.26.2.1.-B CGSB | CAN/CGSB-37.58-M86 | Membrane, Elastomeric, Cold-Applied Liquid, for Non-Exposed Use in Roofing and Waterproofing | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B CGSB | CAN/CGSB-51.25-M87 | Thermal Insulation, Phenolic, Faced | Table 9.23.17.2.-A 9.25.2.2.(1) CGSB | 51-GP-27 M-1979 | Thermal Insulation, Polystyrene, Loose Fill | 9.25.2.2.(1) CGSB | CAN/CGSB-51.32-M77 | Sheathing, Membrane, Breather Type | Table 5.9.1.1. 9.20.13.9.(1) Table 9.26.2.1.-A 9.27.3.2.(1) CGSB | CAN/CGSB-51.33-M89 | Vapour Barrier, Sheet, Excluding Polyethylene, for Use in Building Construction | Table 5.9.1.1. 9.25.4.2.(5) CGSB | CAN/CGSB-51.34-2022 | Polyethylene sheet for use in building construction – Material specification | Table 5.9.1.1. 9.13.2.2.(2) 9.13.4.2.(1.2) 9.18.6.2.(1) 9.25.3.2.(2) 9.25.4.2.(4) CGSB | CAN/CGSB-51.71-2005 | Depressurization Test | 9.32.3.8.(7) CGSB | CAN/CGSB-82.6-M86 | Doors, Mirrored Glass, Sliding or Folding, Wardrobe | 9.6.1.2.(2) CGSB | CAN/CGSB-93.1-M85 | Sheet, Aluminum Alloy, Prefinished Residential | Table 5.9.1.1. 9.27.11.1.(3) CGSB | CAN/CGSB-93.2-M91 | Prefinished Aluminum Siding, Soffits and Facsia for Residential Use | 3.2.3.6.(5) Table 5.9.1.1. 9.10.14.5.(12) 9.27.11.1.(2) CSA | CAN/CSA-6.19-17 | Residential carbon monoxide alarming devices | 6.9.4.4.(1) 9.32.3.9.(2) 9.32.3.9C.(1) CSA | A23.1:19 | Concrete materials and methods of concrete construction | 4.2.3.6.(1) 4.2.3.9.(1) Table 5.9.1.1. 9.3.1.1.(1) 9.3.1.1.(4) 9.3.1.3.(1) 9.3.1.4.(1) 9.40.1.4.(1) CSA | A23.3:19 | Design of concrete structures | Table 4.1.8.9. 4.1.8.18.(7) 4.3.3.1.(1) CSA | A60.1-M1976 | Vitrified Clay Pipe | 7.2.5.3.(1) CSA | A60.3-M1976 | Vitrified Clay Pipe Joints | 7.2.5.3.(2) CSA | CAN/CSA-A82-14 | Fire masonry brick made from clay or shale | Table 5.9.1.1. 9.20.2.1.(1) CSA | CAN/CSA-A82.27-M91 | Gypsum Board | 3.1.5.14.(6) 3.1.5.15.(4) 3.1.6.6.(2) 3.1.6.6.(3) 3.1.6.6.(4) 3.1.6.6.(5) 3.1.6.15.(1) 9.29.5.2.(1) CSA | A82.30-M1980 | Interior Furring, Lathing and Gypsum Plastering | 9.29.4.1.(1) CSA | A82.31-M1980 | Gypsum Board Application | 3.2.3.6.(5) 9.10.9.2.(5) 9.10.12.4.(3) 9.10.14.5.(12) 9.29.5.1.(2) CSA | CAN3-A93-M82 | Natural Airflow Ventilators for Buildings | Table 5.9.1.1. 9.19.1.2.(5) CSA | CAN/CSA-A123.2-03 | Asphalt Coated Roofing Sheets | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B CSA | A123.3-05 | Asphalt Saturated Organic Roofing Felt | Table 5.9.1.1. Table 9.26.2.1.-B CSA | CAN/CSA-A123.4-04 | Asphalt for Constructing Built-Up Roof Coverings and Waterproofing Systems | Table 5.9.1.1. 9.13.2.2.(2) 9.13.3.2.(2) Table 9.26.2.1.-B CSA | A123.5:16 | Asphalt shingles made from glass felt and surfaced with mineral granules | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B CSA | CAN/CSA-A123.16:04 | Asphalt-coated glass-base sheets | Table 5.9.1.1. Table 9.26.2.1.-B CSA | A123.17-05 | Asphalt Glass Felt Used in Roofing and Waterproofing | Table 5.9.1.1. 9.13.3.2.(2) Table 9.26.2.1.-B CSA | CAN/CSA-A123.21:20 | Standard test method for the dynamic wind uplift resistance of membrane-roofing systems | 5.2.2.2.(4) CSA | A123.22-08 | Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | Table 9.26.2.1-.B CSA | A123.23-15 | Product specification for polymer-modified bitumen sheet, prefabricated and reinforced | Table 5.9.1.1. Table 9.26.2.1.-B CSA | A123.51-14 | Asphalt shingle application on roof slopes 1:6 and steeper | Table 5.9.1.1. 9.26.1.3.(1) CSA | A165.1-14 | Concrete block masonry units | Table 5.9.1.1. 9.15.2.2.(1) 9.17.5.1.(1) 9.20.2.1.(1) 9.20.2.6.(1) CSA | A165.2-14 | Concrete brick masonry units | Table 5.9.1.1. 9.20.2.1.(1) CSA | A165.3-14 | Prefaced concrete masonry units | Table 5.9.1.1. 9.20.2.1.(1) CSA | CAN/CSA-A179-14 | Mortar and Grout for Unit Masonry | Table 5.9.1.1. 9.15.2.2.(3) 9.20.3.1.(1) CSA | CAN/CSA-A220 Series-06 | Concrete Roof Tiles | Table 5.9.1.1. Table 9.26.2.1.-B 9.26.17.1.(1) CSA | A257.1:19 | Non-reinforced circular concrete culvert, storm drain, sewer pipe, and fittings | 7.2.5.2.(1) CSA | A257.2:19 | Reinforced circular concrete culvert, storm drain, sewer pipe, and fittings | 7.2.5.2.(1) CSA | A257.3:19 | Joints for circular concrete sewer and culvert pipe, manhole sections, and fittings using rubber gaskets | 7.2.5.2.(2) CSA | A257.4:19 | Precast reinforced circular concrete manhole sections, catch basins, and fittings | 7.2.5.2.(5) CSA | A277-16 | Procedure for certification of prefabricated buildings, modules, and panels | 9.1.1.9.(1) 1.12.1.1.(1) of Division C 3.1.1.1.(2) of Division C 3.2.4.1.(3) of Division C CSA | CAN/CSA-A324-M88 | Clay Flue Liners | 9.21.3.3.(1) CSA | CAN/CSA-A371-14 | Masonry Construction for Buildings | Table 5.9.1.1. 9.15.2.2.(3) 9.20.3.2.(7) 9.20.15.2.(1) CSA | CAN/CSA-A405-M87 | Design and Construction of Masonry Chimneys and Fireplaces | 9.21.3.5.(1) 9.22.1.4.(1) 9.22.5.2.(2) CSA | AAMA/WDMA/CSA 101/I.S.2/A440-17 | NAFS – North American Fenestration Standard/Specification for windows, doors, and skylights | 5.9.2.2.(1) Table 9.7.3.3. 9.7.4.1.(1) 9.7.4.2.(1) 9.7.5.1.(1) 9.7.5.3.(1) CSA | A440S1:19 | Canadian Supplement to AAMA/WDMA/CSA 101/I.S.2/A440-17, NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights | 5.9.2.2.(1) 5.9.3.5.(3) 9.7.4.2.(1) 9.7.4.3.(1) CSA | A440.2-14 | Fenestration Energy Performance | 12.3.1.2.(1) CSA | A440.2:19 / A440.3:19 | Fenestration Energy Performance / user Guide to CSA A440.2-14, Fenestration energy performance | Table 9.7.3.3. CSA | CAN/CSA-A440.4:19 | Window, door, and skylight installation | 9.7.6.1.(1) CSA | A660-10 | Certification of manufacturers of steel building systems | 4.3.4.3.(1) CSA | A3001-18 | Cementitious Materials for Use in Concrete | Table 5.9.1.1. 9.3.1.2.(1) 9.28.2.1.(1) CSA | B52:23 | Mechanical refrigeration code | 6.3.1.5.(4) CSA | B64.0-21 | Definitions, general requirements, and test methods for vacuum breakers and backflow preventers | 7.2.10.10.(1) CSA | B64.1.1-21 | Atmospheric vacuum breakers (AVB) | 7.2.10.10.(1) CSA | B64.1.2-21 | Pressure vacuum breakers (PVB) | 7.2.10.10.(1) CSA | B64.1.3-21 | Spill-resistant pressure vacuum breakers (SRPVB) | 7.2.10.10.(1) CSA | B64.1.4-11 | Vacuum breaker, air space type (ASVB) | 7.2.10.10.(1) CSA | B64.2-21 | Hose connection vacuum breakers (HCVB) | 7.2.10.10.(1) CSA | B64.2.1-21 | Hose connection vacuum breakers (HCVB) with manual draining feature | 7.2.10.10.(1) CSA | B64.2.1.1-11 | Hose connection dual check vacuum breakers (HCDVB) | 7.2.10.10.(1) CSA | B64.2.2-21 | Hose connection vacuum breakers (hcvb) with automatic draining feature | 7.2.10.10.(1) CSA | B64.3-21 | Dual check valve backflow preventers with atmospheric port (DCAP) | 7.2.10.10.(1) 7.6.2.5A.(4) CSA | B64.3.1-11 | Dual check valve backflow preventers with atmospheric port for carbonators (DCAPC) | 7.2.10.10.(1) CSA | B64.4-21 | Reduced Pressure Principle (RP) backflow preventers | 7.2.10.10.(1) 7.6.2.4.(2) CSA | B64.4.1-21 | Reduced pressure principle backflow preventers for fire protection systems (RPF) | 7.2.10.10.(1) 7.6.2.4.(2) 7.6.2.4.(4) CSA | B64.5-21 | Double check valve (DCVA) backflow preventers | 7.2.10.10.(1) 7.6.2.4.(2) CSA | B64.5.1-21 | Double check valve backflow preventers for fire protection systems (DCVAF) | 7.2.10.10.(1) 7.6.2.4.(2) CSA | B64.6-21 | Dual check valve (DuC) backflow preventers | 7.2.10.10.(1) 7.6.2.4.(2) 7.6.2.6.(3) 7.7.1.1.(6) CSA | B64.6.1-21 | Dual check valve backflow preventers for fire protection systems (DuCF) | 7.2.10.10.(1) 7.6.4.2.(2) CSA | B64.7-21 | Laboratory faucet vacuum breakers (LFVB) | 7.2.10.10.(1) CSA | B64.8-21 | Dual check valve backflow preventers with intermediate vent (DuCV) | 7.2.10.10.(1) CSA | B64.9-21 | Single check valve backflow preventers for fire protection systems (SCVAF) | 7.2.10.10.(1) 7.6.2.4.(2) CSA | B64.10-17 | Selection and installation of backflow preventers | 7.2.10.10.(1) 7.6.2.3.(1) 7.6.2.6.(1) CSA | B66-21 | Design, material, and manufacturing requirements for prefabricated septic tanks and sewage holding tanks | 8.2.2.2.(1) 8.2.2.2.(2) 8.2.2.3.(7) 8.2.2.3.(11) CSA | B70-19 | Cast iron soil pipe, fittings and means of joining | 7.2.6.1.(1) 7.4.6.4.(2) CSA | B70.1-03 | Frames and Covers for Maintenance Holes and Catchbasins | 7.2.6.2.(1) CSA | B111-1974 | Wire Nails, Spikes and Staples | 9.23.3.1.(1) 9.26.2.3.(1) 9.29.5.6.(1) CSA | B125.3-18 | Plumbing fittings | 7.2.10.6.(1) 7.2.10.7.(2) 7.2.10.7.(3) 7.2.10.7B.(2) CSA | CAN/CSA-B126.0-13 | General requirements and methods of testing for water cisterns | 7.7.2.4.(6) CSA | CAN/CSA-B126.1-13 | Installation of water cisterns | 7.7.2.4.(6) CSA | CAN/CSA-B127.3-21 | Fibrocement drain, waste, and vent pipe and pipe fittings | 7.2.5.1.(1) CSA | CAN/CSA-B128.1-06 | Design and installation of non-potable water systems | 7.7.1.2.(1) 7.7.3.1.(1) CSA | B137.1-20 | Polyethylene (PE) pipe, tubing and fittings for cold water pressure services | 7.2.5.4.(1) Table 7.2.11.2. CSA | B137.2-20 | Polyvinylchloride (PVC) injection-moulded gasketed fittings for pressure applications | 7.2.5.7.(3) 7.2.5.9.(1) CSA | B137.3-20 | Rigid polyvinylchloride (PVC) pipe and fittings for pressure applications | 7.2.5.7.(1) 7.2.5.9.(1) Table 7.2.11.2. CSA | B137.5-20 | Crosslinked polyethylene (PEX) tubing systems for pressure applications | 7.2.5.6.(1) Table 7.2.11.2. CSA | B137.6-20 | Chlorinated polyvinylchloride (CPVC) pipe, tubing, and fittings for hot- and cold-water distribution systems | 7.2.5.8.(1) Table 7.2.11.2. CSA | B137.9-20 | Polyethylene/aluminum/polyethylene (PE-AL-PE) composite pressure- pipe systems | 7.2.5.12.(1) Table 7.2.11.2. CSA | B137.10-20 | Crosslinked polyethylene/aluminum crosslinked polyethylene (PEX-AL-PEX) composite pressure-pipe systems | 7.2.5.12.(4) 7.2.5.13.(1) Table 7.2.11.2. CSA | B137.11-20 | Polypropylene (PP-R) pipe and fittings for pressure applications | 7.2.5.14.(1) CSA | B137.18-20 | Polyethylene of raised temperature resistance (PE-RT) tubing systems for pressure applications | 7.2.5.15.(1) CSA | B158.1-1976 | Cast Brass Solder Joint Drainage, Waste and Vent Fittings | 7.2.10.1.(1) CSA | B149.1-20 | Natural gas and propane installation code | 2.4.2.2.(1) CSA | B149.6-20 | Code for digester gas, landfill gas, and biogas generation and utilization | 2.2.8.1.(3) CSA | B181.1-21 | Acrylonitrile-butadiene-styrene (ABS) drain, waste, and vent pipe and pipe fittings | 7.2.5.9.(1) 7.2.5.10.(1) 7.2.5.11.(1) 7.2.5.11.(1.1) 7.2.10.1.(2) 7.4.6.4.(2) CSA | B181.2-21 | Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) drain, waste, and vent pipe and pipe fittings | 7.2.5.9.(1) 7.2.5.10.(1) 7.2.5.11.(1) 7.2.5.11.(1.1) 7.2.5.16.(1) 7.2.5.16.(2) 7.2.10.1.(3) 7.4.6.4.(2) CSA | B181.3-21 | Polyolefin and polyvinylidene fluoride (PVDF) laboratory drainage systems | 7.2.8.1.(1) CSA | B182.1-21 | Plastic drain and sewer pipe and pipe fittings | Table 5.9.1.1. 7.2.5.9.(1) 7.2.5.11.(1.1) 7.4.6.4.(2) 9.14.3.1.(1) CSA | B182.2-21 | PSM type polyvinylchloride (PVC) sewer pipe and fittings | 7.2.5.9.(1) 7.2.5.11.(1.1) CSA | B182.4-21 | Profile polyvinylchloride (PVC) sewer pipe and fittings | 7.2.5.9.(1) CSA | B182.6-21 | Profile polyethylene (PE) sewer pipe and fittings for leak-proof sewer applications | 7.2.5.9.(1) CSA | B182.8-21 | Profile polyethylene (PE) storm sewer and drainage pipe and fittings | 7.2.5.9.(1) CSA | B214-21 | Installation code for hydronic heating systems | 6.2.1.1.(1) 6.2.1.5.(6) 9.33.4.2.(1) CSA | B242-05 | Groove- and Shoulder-Type Mechanical Pipe Couplings | 7.2.10.4.(1) CSA | B272-93 | Prefabricated Self-Sealing Roof Vent Flashings | 7.2.10.14.(2) CSA | B355:19 | Platform lifts and stair lifts for barrier-free access | 3.8.3.5.(1) CSA | CAN/CSA-B356-10 | Water pressure reducing valves for domestic water supply systems | 7.2.10.12.(1) CSA | B365-17 | Installation code for solid-fuel-burning appliances and equipment | 6.2.1.5.(1) 6.2.1.5.(5) 9.21.1.4.(1) 9.22.10.2.(1) 9.33.5.3.(1) CSA | B366.1-11 | Solid-Fuel-Fired Central Heating Appliances | 6.2.1.5.(2) CSA | B415.1-22 | Performance Testing of Solid-Fuel-Burning Heating Appliances | 6.2.1.5.(7) 9.33.5.3.(2) CSA | B481.0-12 | Material, design, and construction requirements for grease interceptors | 7.2.3.2.(3) CSA | B481.1-12 | Testing and Rating of Grease Interceptors Using Lard | 7.2.3.2.(4) 8.1.3.1.(8) CSA | B481.2-12 | Testing and Rating of Grease Interceptors Using Oil | 7.2.3.2.(4) 8.1.3.1.(8) CSA | B481.3-12 | Sizing, Selection, Location, and Installation of Grease Interceptors | 7.2.3.2.(3) CSA | B481.4-12 | Maintenance of Grease Interceptors | 8.9.3.3.(1) CSA | CAN/CSA-B483.1-21 | Drinking Water Treatment Systems | 7.2.10.17.(1) CSA | B602-20 | Mechanical couplings for drain, waste, and vent pipe and sewer pipe | 7.2.10.4.(2) CSA | B651-18 | Accessible design for the built environment | 3.8.3.1.(7) 3.8.3.1.(8) CSA | C22.2 No. 0.3-09 | Test methods for electrical wires and cables | 3.1.4.3.(1) 3.1.4.3.(3) 3.1.5.21.(1) 3.1.5.21.(3) 3.1.5.25.(1) 3.1.5.25.(2) 9.34.1.5.(1) CSA | C22.2 No.113-10 | Fans and Ventilators | 9.32.3.10.(7) CSA | C22.2 No. 141:15 | Emergency lighting equipment | 3.2.7.4.(2) 3.4.5.1.(3) 9.9.11.3.(3) 9.9.12.3.(7) CSA | C22.2 No. 211.0-03 | General Requirements and Methods of Testing for Nonmetallic Conduit | 3.1.5.23.(1) CSA | CAN/CSA-C22.2 No. 262-04 | Optical Fiber Cable and Communication Cable Raceway Systems | 3.1.5.23.(1) CSA | CAN/CSA-C22.3 No. 1-20 | Overhead Systems | 3.1.20.1.(2) CSA | CAN/CSA-C88-M90 | Power Transformers and Reactors | 3.6.2.7.(10) CSA | CAN/CSA-C260-M90 | Rating for the Performance of Residential Mechanical Ventilating Equipment | 9.32.3.10.(1) 9.32.3.10.(2) Table 9.32.3.10.-B CSA | C282-15 | Emergency electrical power supply for buildings | 3.2.7.5.(1) CSA | CAN/CSA-C439-18 | Standard laboratory methods of test for rating the performance of heat/energy-recovery ventilators | 9.32.3.10.(4) 9.32.3.10.(5) CSA | CAN/CSA-C448.1-13 | Design and Installation of Earth Energy Systems for Commercial and Institutional Buildings | 6.2.1.5.(4) 9.33.5.2.(2) CSA | CAN/CSA-C448.2-13 | Design and Installation of Earth Energy Systems for Residential and Other Small Buildings | 6.2.1.5.(3) 9.33.5.2.(1) CSA | F280-12 | Determining the required capacity of residential space heating and cooling appliances | 9.33.4.1.(1) 9.33.5.1.(3) CSA | CAN/CSA-F326-M91 | Residential Mechanical Ventilation Systems | 9.32.3.1.(1) 9.33.4.1.(1) CSA | CAN/CSA- F379 Series-09 (excluding Supplement F379S1-11) | Packaged solar domestic hot water systems (liquid-to-liquid heat transfer) | 7.2.10.13.(1) CSA | CAN/CSA- F379.1-09 | Packaged solar domestic hot water systems (liquid-to-liquid heat transfer) for All Season Use | 7.6.1.8.(1) 7.6.2.5A.(3) 7.6.2.5A.(4) CSA | CAN/CSA-F383-08 | Installation of packaged solar domestic hot water systems | 7.6.1.8.(1) CSA | G30.18-21 | Carbon steel bars for concrete reinforcement | 9.3.1.1.(4) 9.40.1.3.(1) CSA | G40.21-13 | Structural quality steel | 4.2.3.8.(1) Table 5.9.1.1. 9.23.4.3.(2) CSA | CAN/CSA-G164-M92 | Hot Dip Galvanizing of Irregularly Shaped Articles | 4.4.5.1.(4) CSA | CAN/CSA-G401-14 | Corrugated steel pipe products | Table 5.9.1.1. 7.2.6.8.(1) 9.14.3.1.(1) CSA | CAN/CSA-O80 Series-15 | Wood preservation | 3.1.4.5.(1) 4.2.3.2.(1) Table 5.9.1.1. CSA | CAN/CSA-O80.0-21 | General requirements for wood preservation | 4.2.3.2.(2) CSA | CAN/CSA-O80.1-21 | Specification of treated wood | 4.2.3.2.(1) 9.3.2.9.(5) CSA | CAN/CSA-O80.2-21 | Processing and treatment | 4.2.3.2.(1) CSA | CAN/CSA-O80.3-21 | Preservative formulations | 4.2.3.2.(1) CSA | O86:19 | Engineering design in wood | Table 4.1.8.9. 4.3.1.1.(1) CSA | O118.1-08 | Western Red Cedar Shakes and Shingles | Table 5.9.1.1. Table 9.26.2.1.-B 9.27.7.1.(1) CSA | O118.2-08 | Eastern White Cedar Shingles | Table 5.9.1.1. Table 9.26.2.1.-B 9.27.7.1.(1) CSA | O121-17 | Douglas fir plywood | Table 5.9.1.1. Table 9.23.12.3.-A Table 9.23.12.3.-B Table 9.23.12.3.-C Table 9.23.17.2.-A 9.23.15.2.(1) 9.23.16.2.(1) 9.27.8.1.(1) 9.30.2.2.(1) CSA | CAN/CSA-O122-16 | Structural glued-laminated timber | Table 9.23.4.2.-K Table 9.23.12.3.-D CSA | CAN/CSA-O132.2 Series-90 | Wood Flush Doors | 9.7.4.3.(4) CSA | O141:05 | Softwood Lumber | Table 5.9.1.1. 9.3.2.6.(1) CSA | O151-17 | Canadian softwood plywood | Table 5.9.1.1. Table 9.23.12.3.-A Table 9.23.12.3.-B Table 9.23.12.3.-C 9.23.15.2.(1) 9.23.16.2.(1) Table 9.23.17.2.-A 9.27.8.1.(1) 9.30.2.2.(1) CSA | O153-19 | Poplar plywood | Table 5.9.1.1. 9.23.15.2.(1) 9.23.16.2.(1) Table 9.23.17.2.-A 9.27.8.1.(1) 9.30.2.2.(1) CSA | O177-06 | Qualification Code for Manufacturers of Structural Glued-Laminated Timber | 4.3.1.2.(1) Table 9.23.4.2.-K Table 9.23.12.3.-D CSA | O325-21 | Construction sheathing | Table 5.9.1.1. Table 9.23.12.3.-A Table 9.23.12.3.-B Table 9.23.12.3.-C Table 9.23.13.6. 9.23.15.2.(1) 9.23.15.4.(2) 9.23.16.2.(1) 9.23.16.3.(2) Table 9.23.16.7.-B Table 9.23.17.2.-A Table 9.23.17.2.-B 9.29.9.1.(2) 9.29.9.2.(5) CSA | O437.0-93 | OSB and Waferboard | Table 5.9.1.1. Table 9.23.12.3.-A Table 9.23.12.3.-B Table 9.23.12.3.-C 9.23.15.2.(1) 9.23.15.4.(2) 9.23.16.2.(1) 9.23.16.3.(2) Table 9.23.17.2.-A 9.27.10.1.(1) 9.29.9.1.(2) 9.30.2.2.(1) CSA | S16-19 | Design of Steel Structures | Table 4.1.8.9. 4.3.4.1.(1) CSA | S37-18 | Antennas, Towers, and Antenna-Supporting Structures | 4.1.6.15.(1) 4.1.7.11.(1) CSA | S136-16 | North American specification for the design of cold formed steel structural members (using the Appendix B provisions applicable to Canada) | 4.1.8.1.(5) Table 4.1.8.9. 4.3.4.2.(1) CSA | S157-17 / S157.1-17 | Strength design in aluminum / Commentary on CSA S157-17, Strength design in aluminum | 4.3.5.1.(1) CSA | S304-14 | Design of masonry structures | Table 4.1.8.9. 4.3.2.1.(1) CSA | S367-12 | Air-, cable-, and frame-supported membrane structures | 4.4.1.1.(1) CSA | S406-16 | Specification of permanent wood foundations for housing and small buildings | 9.13.2.7.(1) 9.15.2.4.(1) 9.16.5.1.(1) CSA | S413-21 | Parking structures | 4.4.2.1.(1) CSA | S478-19 | Durability in buildings | 5.1.4.2.(3) Table 5.9.1.1. CSA | Z32-15 | Electrical safety and essential electrical systems in health care facilities | 3.2.7.3.(4) 3.2.7.6.(1) 3.7.5.1.(1) CSA | Z240 MH Series-16 | Manufactured homes | 3.1.1.1.(2) of Division C 3.2.4.1.(3) of Division C CSA | Z240.2.1-16 | Structural requirements for manufactured homes | 9.1.1.9.(1) 9.12.2.2.(6) 9.15.1.3.(1) CSA | Z240.10.1-19 | Site preparation, foundation, and installation of buildings | 9.15.1.3.(1) 9.23.6.3.(1) CSA | CAN/CSA-Z241 Series-18 | Park model trailers | 9.39.1.1.(1) 9.39.2.1.(1) 3.1.1.1.(2) of Division C 3.2.4.1.(3) of Division C CSA | CSA Z271:20 | Design of suspended access equipment | 4.4.5.1.(2) CSA | CAN/CSA-Z317.2-15 | Special requirements for heating, ventilation and air conditioning (HVAC) systems in health care facilities | 6.2.1.1.(1) 6.2.3.15.(6) CSA | CAN/CSA-Z662-15 | Oil and gas pipeline systems | 3.2.3.22.(1) CSA | Z7396.1-17 | Medical gas piping systems - Part 1: Pipelines for medical gases, medical vacuum, medical support gases, and anaesthetic gas scavenging systems | 3.7.5.2.(1) CSA / IAPMO | CSA B45.5-17 / IAPMO Z124-2017 | Plastic plumbing fixtures | 7.2.2.2.(1) CSA / ICC | CSA B805-18 / ICC 805-2018 | Rainwater harvesting systems | 7.7.2.4.(4) CSSBI | 23 M-2016 | Standard for Residential Steel Cladding | 9.27.11.1.(1) CWC | 2014 | Engineering Guide for Wood Frame Construction | 9.4.1.1.(1) 9.23.13.1.(2) 9.23.13.2.(2) 9.23.13.3.(2) DBR | Technical Paper No. 194, May 1965 | Fire Endurance of Protected Steel Columns and Beams | Table 11.5.1.1.-A Table 11.5.1.1.-B Table 11.5.1.1.-C Table 11.5.1.1.-D/E Table 11.5.1.1.-F DBR | Technical Paper No. 207, October 1965 | Fire Endurance of Unit Masonry Walls | Table 11.5.1.1.-A Table 11.5.1.1.-B Table 11.5.1.1.-C Table 11.5.1.1.-D/E Table 11.5.1.1.-F DBR | Technical Paper No. 222, June 1966 | Fire Endurance of Light-Framed and Miscellaneous Assemblies | Table 11.5.1.1.-A Table 11.5.1.1.-B Table 11.5.1.1.-C Table 11.5.1.1.-D/E Table 11.5.1.1.-F EPA | 625/R-92/016 (1994) | Radon Prevention in the Design and Construction of Schools and Other Large Buildings | 6.2.1.1.(1) FINA | 2021 | Rules and Regulations - FINA Facilities Rules 2021-2025 - FR3 Diving | 3.11.4.1.(17) HC | SOR/2015-17 | Hazardous Products Regulations | 1.4.1.2.(1) of Division A HI | 2005 | Hydronics Institute Manuals | 6.2.1.1.(1) 9.32.2.3.(4) 9.32.3.2.(1) 9.33.4.1.(1) 9.33.6.7.(2) HPVA | ANSI/HPVA HP-1-2009 | American National Standard for Hardwood and Decorative Plywood | Table 5.9.1.1. 9.27.8.1.(1) 9.30.2.2.(1) HRAI | 2017 Edition | HRAI Digest | 6.2.1.1.(1) 9.32.2.3.(4) 9.32.3.2.(1) 9.33.4.1.(1) HUD | Rehabilitation Guidelines 2000 | Guideline on Fire Ratings of Archaic Materials and Assemblies | Table 11.5.1.1.-A Table 11.5.1.1.-B Table 11.5.1.1.-C Table 11.5.1.1.-D/E Table 11.5.1.1.-F HVI | HVI 915-2016 | Loudness Testing and Rating Procedure | 9.32.3.10.(2) Table 9.32.3.10.-B HVI | HVI 916-2015 | Airflow Test Procedure | 9.32.3.10.(1) IAPMO | PS 63-2014 | Plastic Leaching Chambers | 8.7.2.3.(3) ISO | 3864-1:2011 | Graphical symbols – Safety colours and safety signs – Part 1: Design principles for safety signs and safety markings | 3.4.5.1.(2) 9.9.11.3.(2) ISO | 7010:2011 | Graphical symbols - Safety colours and safety signs - Registered safety signs | 3.4.5.1.(2) 9.9.11.3.(2) ISO | 8201:2017 | Acoustics - audible emergency evacuation signal | 3.2.4.18.(2) ISO | 10848-1:2017 | Acoustics - Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms | 5.8.1.4.(2) 5.8.1.4.(3) 5.8.1.5.(2) 5.8.1.5.(3) ISO | 12354-1:2017 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 1: Airborne sound insulation between rooms | 5.8.1.4.(1) 5.8.1.4.(2) 5.8.1.4.(4) 5.8.1.4.(5) 5.8.1.4.(6) 5.8.1.5.(1) 5.8.1.5.(2) 5.8.1.5.(5) 5.8.1.5.(6) ISO | 23599:2019 | Assistive products for blind and vision-impaired persons – Tactile walking surface indicators | 3.8.3.18.(1) MMAH | Supplementary Standard SA-1, September 9, 2024 | Objectives and Functional Statements Attributed to the Acceptable Solutions | 1.2.1.1.(1) of Division A 1.2.1.1.(2) of Division A MMAH | Supplementary Standard SB-1, January 1, 2024 | Climatic and Seismic Data | 1.1.2.1.(1) 1.1.2.1.(2) 2.1.2.3.(4) 2.1.2.3.(5) 3.2.6.2.(2) 3.2.8.4.(1) 3.3.1.7.(1) 5.2.1.1.(1) 5.2.1.1.(2) 6.2.1.2.(1) 7.4.10.4.(1) 9.4.1.1.(3) 9.4.2.2.(1) Tables 9.6.1.3.-A to 9.6.1.3.-G Table 9.32.3.4. 9.33.3.2.(1) 9.33.4.1.(1) MMAH | Supplementary Standard SB-2, January 1, 2024 | Fire Performance Ratings | 2.2.1.10.(2) 3.1.4.8.(4) 3.1.5.5.(4) 3.1.5.6.(2) 3.1.5.29.(1) 3.1.6.9.(6) 3.1.6.10.(2) 3.1.7.1.(2) 3.1.8.16.(2) 3.1.9.5.(1) 3.1.12.1.(3) 3.2.3.12.(1) 3.2.3.13.(4) 3.6.1.5.(1) 3.13.2.1.(11) 3.13.3.5.(1) 3.13.3.6.(2) 3.13.4.2.(7) 9.10.3.1.(1) 9.10.3.2.(1) 9.10.5.1.(3) 9.10.9.11.(1) MMAH | Supplementary Standard SB-3, January 1, 2024 | Fire and Sound Resistance Tables | 5.8.1.3.(1) 5.8.1.3.(2) 9.10.3.1.(1) 9.10.5.1.(3) 9.11.1.3.(1) 9.11.1.3.(2) Table 9.11.1.4. 9.29.5.9.(5) MMAH | Supplementary Standard SB-4, January 1, 2024 | Measures for Fire Safety in High Buildings | 3.2.6.2.(1) 3.2.6.2.(7) 3.2.6.5.(3) 3.2.6.9.(1) 3.13.3.6.(5) Table 11.5.1.1.-C Table 11.5.1.1.-D/E Table 11.5.1.1.-F MMAH | Supplementary Standard SB-6, January 1, 2024 | Percolation Times and Soil Descriptions | 8.2.1.2.(2) MMAH | Supplementary Standard SB-7, January 1, 2024 | Guards for Housing and Small Buildings | 9.8.8.2.(6) MMAH | Supplementary Standard SB-8, January 1, 2024 | Design, Construction and Installation of Anchorage Systems for Fixed Access Ladders | 3.6.1.6.(1) MMAH | Supplementary Standard SB-9, January 1, 2024 | Requirements for Soil Gas Control | 9.13.4.1.(3) 9.13.4.2.(1) MMA | Supplementary Standard SB-10, December 22, 2016 | Energy Efficiency Requirements | Table 9.7.3.3. 12.2.1.2.(2) 12.2.2.1.(1) 12.2.3.1.(1) MMAH | Supplementary Standard SB-11, January 1, 2024 | Construction of Farm Buildings | 2.1.2.3.(5) MMA | Supplementary Standard SB-12, July 7, 2016 | Energy Efficiency for Housing | Table 9.7.3.3. Table 11.5.1.1.-C 12.2.1.2.(3) MMAH | Supplementary Standard SB-13, January 1, 2024 | Glass in Guards | 3.1.21.1.(1) MMAH | Supplementary Standard SC-1, January 1, 2024 | Code of Conduct for Registered Code Agencies | 3.7.4.1.(2) of Division C MOE | PIBS 6879 2008 | Design Guidelines for Sewage Works | 7.1.2.5.(1) MOE | PIBS 6881e 2008 | Design Guidelines for Drinking-Water Systems | 7.1.2.5.(2) NFPA | 2023 Publication | National Fire Codes | 6.2.1.1.(1) NFPA | 13-2019 | Standard for the Installation of Sprinkler Systems | 3.1.9.1.(4) 3.2.4.8.(2) 3.2.4.15.(1) 3.2.5.12.(1) 3.2.5.12.(9) 3.2.8.2.(5) 3.2.8.3.(2) 3.3.2.14.(3) 3.16.1.1.(3) 3.16.1.1.(4) 3.16.1.6.(2) 3.16.1.6.(8) 3.16.1.7.(2) 3.16.2.1.(1) 3.16.2.2.(1) 3.16.3.1.(1) 9.10.9.9.(4) NFPA | 13D-2016 | Standard for the Installation of Sprinkler Systems in One- and Two- Family Dwellings and Manufactured Homes | 3.2.4.1.(2) 3.2.5.12.(3) 3.2.7.9.(4) 3.19.4.1.(1) NFPA | 13R-2019 | Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies | 3.2.5.12.(2) NFPA | 14-2013 | Standard for the Installation of Standpipe and Hose Systems | 3.2.5.9.(1) 3.2.5.10.(1) NFPA | 20-2016 | Standard for the Installation of Stationary Pumps for Fire Protection | 3.2.4.9.(4) 3.2.5.18.(1) NFPA | 24-2013 | Standard for the Installation of Private Fire Service Mains and Their Appurtenances | 7.2.11.1.(1) NFPA | 68-2013 | Standard on Explosion Protection by Deflagration Venting | 3.3.6.3.(1) 3.3.6.4.(2) 3.3.6.4.(1) NFPA | 72-2019 | National Fire Alarm and Signaling Code | 3.2.4.20.(17) 6.9.4.4.(3) 9.10.19.1.(2) 9.10.19.3.(4) NFPA | 80-2013 | Standard for Fire Doors and Other Opening Protectives | 3.1.8.5.(2) 3.1.8.12.(2) 3.1.8.16.(1) 3.1.9.1.(5) 3.13.3.1.(2) 9.10.9.9.(5) 9.10.13.1.(1) NFPA | 82-2014 | Standard on Incinerators and Waste and Linen Handling Systems and Equipment | 6.2.2.1.(1) 9.10.10.5.(2) NFPA | 91-2015 | Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists and Noncombustible Particulate Solids | 6.3.4.3.(1) NFPA | 2001-2022 | Standard on Clean Agent Fire Extinguishing Systems | 3.13.3.3.(3) 3.13.3.3.(4) NFPA | 96-2021 | Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations | 3.2.4.8.(2) 3.6.3.5.(1) 6.3.1.6.(1) NFPA | 105-2013 | Standard for Smoke Door Assemblies and other Opening Protectives | 3.1.8.5.(3) 3.1.8.5.(7) NFPA | 130-2023 | Standard for Fixed Guideway Transit and Passenger Rail Systems | 3.13.7.1.(1) NFPA | 211-2019 | Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances | 6.3.3.2.(2) 6.3.3.3.(1) NFPA | 701-2023 | Standard Methods of Fire Tests for Flame Propagation of Textiles and Films | 3.14.1.6.(1) 3.14.2.5.(1) 3.17.2.5.(1) NFRC | 100-2014 | Procedure for Determining Fenestration Product U-Factors | 12.3.1.2.(1) NFRC | 200-2014 | Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence | 12.3.1.2.(1) NLGA | 2017 | Standard Grading Rules for Canadian Lumber | 1.4.1.2.(1) of Division A 9.3.2.1.(1) Table 9.3.2.1. Tables 9.23.4.2.-A to 9.23.4.3.-J NSF | NSF/ANSI 46-2010 | Evaluation of Components and Devices Used in Wastewater Treatment Systems | 8.6.2.1.(2) NSF | NSF/ANSI 61-2016 | Drinking Water System Components - Health Effects | 7.2.10.7C.(1) SMACNA | ANSI/SMACNA 006- 2006 | HVAC Duct Construction Standards - Metal and Flexible | 9.33.6.5.(2) 9.33.6.7.(9) 9.33.6.7.(10) SPRI | ANSI/GRHC/SPRI VR-1- 2018 | Procedure for Investigating Resistance to Root or Rhizome Penetration on Vegetative Roofs | 5.6.1.2.(2) TPIC | 2019 | Truss Design Procedures and Specifications for Light Metal Plate Connected Wood Trusses | 9.23.14.11.(1) TRCA | June 2020 | Toronto and Region Conservation Authority and the City of Brampton – Downtown Brampton Flood Protection Project Environmental Assessment Environmental Study Report | 1.3.3.6.A(4) of Division C UL | ANSI/CAN/UL/ULC 300-2022 | Standard for Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment | 6.9.1.3.(1) UL | ANSI/UL-1784-2015 | Standard for Air Leakage Tests of Door Assemblies and Other Opening Protectives | 3.1.8.4.(4) UL | UL 2034-2008 | Single and Multiple Station Carbon Monoxide Alarms | 9.33.3.9C.(1) ULC | CAN/ULC-S101-14 | Standard Method of Fire Endurance Tests of Building Construction and Materials | 2.2.1.8.(4) 2.2.1.10.(1) 3.1.5.7.(2) 3.1.5.14.(5) 3.1.5.14.(6) 3.1.5.15.(3) 3.1.5.15.(4) 3.1.7.1.(1) 3.1.11.7.(1) 3.2.3.8.(1) 9.10.16.3.(1) ULC | CAN/ULC-S102:2018 | Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies | 3.1.5.24.(1) 3.1.12.1.(1) Table 5.9.1.1. Table 9.23.17.2.-A 9.29.5.2.(1) ULC | CAN/ULC-S102.2-18 | Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous Materials and Assemblies | 3.1.12.1.(2) 3.1.13.4.(1) 9.27.12.1.(4) 9.27.13.1.(2) ULC | CAN/ULC-S102.3-2018 | Standard Method of Fire Test of Light Diffusers and Lenses | 3.1.13.4.(1) ULC | CAN/ULC-S102.4-17 | Standard Method of Test for Fire and Smoke Characteristics of Electrical Wiring, Cables and Non-Metallic Raceways | 3.1.4.3.(2) 3.1.5.21.(2) 3.1.5.23.(2) ULC | CAN/ULC-S104-15 | Standard Method for Fire Tests of Door Assemblies | 3.1.8.4.(1) 3.2.6.5.(3) ULC | CAN/ULC-S105-16 | Standard Specification for Fire Door Frames Meeting the Performance Required by CAN/ULC-S104 | 9.10.13.6.(1) ULC | CAN/ULC-S106-15 | Standard Methods for Fire Tests of Window and Glass Block Assemblies | 3.1.8.4.(1) ULC | CAN/ULC-S107-19 | Standard Methods for Fire Tests of Roof Coverings | 3.1.15.1.(1) ULC | CAN/ULC-S109-14 | Standard Method for Flame Tests of Flame-Resistant Fabrics and Films | 2.2.1.14.(1) 3.1.16.1.(1) 3.6.5.2.(2) 3.6.5.3.(1) 3.14.1.6.(1) 3.14.2.5.(1) 3.17.2.5.(1) 9.33.6.3.(1) ULC | CAN/ULC-S110-13 | Standard Methods of Test for Air Ducts | 3.6.5.1.(2) 3.6.5.1.(5) 9.33.6.2.(2) 9.33.6.2.(4) ULC | CAN/ULC-S111-13 | Standard Method of Fire Tests for Air Filter Units | 6.2.3.13.(1) 9.33.6.14.(1) ULC | CAN/ULC-S112-10 | Standard Method of Fire Test of Fire-Damper Assemblies | 3.1.8.4.(1) ULC | CAN/ULC-S112.1-10 | Standard for Leakage Rated Dampers for Use in Smoke Control Systems | 3.1.8.4.(3) 6.3.2.7.(3) ULC | CAN/ULC-S112.2-07 | Standard Method of Fire Test of Ceiling Firestop Flap Assemblies | 3.1.9.4.(2) 3.6.4.3.(2) 9.10.13.14.(1) ULC | CAN/ULC-S113:2016 | Standard Specification for Wood Core Doors Meeting the Performance Required by CAN/ULC-S104 for Twenty Minute Fire Rated Closure Assemblies | 9.10.13.2.(1) ULC | CAN/ULC-S114:2018 | Standard Method of Test for Determination of Non-Combustibility in Building Materials | 1.4.1.2.(1) of Division A ULC | CAN/ULC-S115:2018 | Standard Method of Fire Tests of Firestop Systems | 3.1.5.19.(3) 3.1.8.3.(3) 3.1.9.1.(1) 3.1.9.1.(2) 3.1.9.1.(3) 3.1.9.1.(6) 3.1.9.1.(7) 3.1.9.3.(1) 3.1.9.3.(2) 3.1.9.3.(4) 3.1.9.4.(4) 3.1.9.4.(7) 9.10.9.2.(3) 9.10.9.6.(1) 9.10.9.6.(2) 9.10.9.8.(1) 9.10.9.8.(6) ULC | CAN/ULC-S124-06 | Standard Method of Test for the Evaluation of Protective Coverings for Foamed Plastic | 3.1.5.15.(2) ULC | CAN/ULC-S126-14 | Standard Method of Test for Fire Spread Under Roof-Deck Assemblies | 3.1.14.1.(1) 3.1.14.2.(1) ULC | CAN/ULC-S134-13 | Standard Method of Fire Test of Exterior Wall Assemblies | 3.1.5.5.(1) 9.10.15.5.(2) ULC | ULC-S135-04 | Standard Test Method for the Determination of Combustibility Parameters of Building Materials Using an Oxygen Consumption Calorimeter (Cone Calorimeter) | 3.1.5.1.(2) ULC | CAN/ULC-S136:2021 | Standard Method for Fire Test of Sprinkler Protected Window Systems | 3.1.8.20.(1) ULC | CAN/ULC-S138-06 | Standard Method of Test for Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration | 3.1.5.7.(1) 3.1.5.7.(3) ULC | CAN/ULC-S139:17 | Standard for Fire Test for Evaluation of Integrity of Electrical Power, Data and Optical Fibre Cables | 3.2.6.5.(6) 3.2.7.10.(2) 3.2.7.10.(3) ULC | CAN/ULC-S143-14 | Standard Method of Fire Tests for Non-Metallic Electrical and Optical Fibre Cable Raceway Systems | 3.1.5.23.(1) ULC | CAN/ULC-S144-12 | Standard Method of Fire Resistance Test - Grease Duct Assemblies | 3.6.3.5.(2) ULC | CAN/ULC-S146-19 | Standard Method of Test for the Evaluation of Encapsulation Materials and Assemblies of Materials for the Protection of Structural Timber Elements | 3.1.6.5.(1) ULC | S505-1974 | Standard for Fusible Links for Fire Protection Service | 3.1.8.10.(2) ULC | CAN/ULC-S524:2019 | Standard for Installation of Fire Alarm Systems | 3.1.8.11.(3) 3.1.8.14.(3) 3.2.4.5.(1) 3.2.4.20.(10) 3.2.4.20.(15) 9.10.19.4.(3) 9.10.19.6.(2) ULC | CAN/ULC-S531:2019 | Standard for Smoke Alarms | 3.2.4.20.(2) 9.10.19.1.(1) ULC | CAN/ULC-S537:2019 | Standard for Verification of Fire Alarm Systems | 3.2.4.5.(2) 3.2.4.20.(10) ULC | CAN/ULC-S540-13 | Standard for Residential Fire and Life Safety Warning Systems: Installation, Inspection, Testing and Maintenance | 3.2.4.21.(1) 9.10.19.8.(1) ULC | CAN/ULC-S553-14 | Standard for the Installation of Smoke Alarms | 3.2.4.20.(13) 9.10.19.3.(2) ULC | CAN/ULC-S561:2022 | Standard for Installation and Services for Fire Signal Receiving Centres and Systems | 3.2.4.7.(4) 3.13.5.4.(1) ULC | CAN/ULC-S572:2017 | Standard for Photoluminescent and Self-Luminous Exit Signs and Path Marking Systems | 3.4.5.1.(4.1) 9.9.11.3.(3) ULC | CAN/ULC-S610:2018 | Standard for Factory-Built Fireplace Systems | 9.22.8.1.(1) ULC | ULC-S628:2022 | Standard for Fireplace Inserts and Hearth-Mounted Stoves | 9.22.10.1.(1) ULC | CAN/ULC-S629:2022 | Standard for 650ºC Factory-Built Chimneys | 9.21.1.3.(1) ULC | CAN/ULC-S639:2018 | Standard for Steel Liner Assemblies for Solid Fuel-Burning Masonry Fireplaces | 9.22.2.3.(1) ULC | CAN/ULC-S701.1:2022 | Standard for Thermal Insulation, Polystyrene Boards | Table 5.9.1.1. Table 9.23.17.1.-A 9.25.2.2.(1) 9.25.2.2.(4) ULC | CAN/ULC-S702.1:2021 | Standard for Mineral Fibre Thermal Insulation for Buildings, Part 1: Material Specification | 3.1.6.3.(4) Table 5.9.1.1. 9.10.9.8.(3) Table 9.23.17.2.-A 9.25.2.2.(1) ULC | CAN/ULC-S703-09 | Standard for Cellulose Fibre Insulation (CFI) for Buildings | Table 5.9.1.1. 9.25.2.2.(1) ULC | CAN/ULC-S704.1:2017 | Standard for Thermal Insulation, Polyurethane and Polyisocyanurate Boards, Faced | Table 5.9.1.1. Table 9.23.17.2.A 9.25.2.2.(1) ULC | CAN/ULC-S705.1:2018 | Standard for Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density - Material – Specification | Table 5.9.1.1. 9.25.2.2.(1) ULC | CAN/ULC-S705.2:2020 | Standard for Thermal Insulation – Spray Applied Rigid Polyurethane Foam, Medium Density – Application | Table 5.9.1.1. 9.25.2.5.(1) ULC | CAN/ULC-S706.1:2016 | Standard for Wood Fibre Insulating Boards for Buildings | Table 5.9.1.1. 9.23.16.7.(3) Table 9.23.17.2.-A 9.25.2.2.(1) 9.29.8.1.(1) ULC | CAN/ULC-S710.1:2019 | Standard for Bead-Applied One Component Polyurethane Air Sealant Foam, Part 1: Material Specification | Table 5.9.1.1. ULC | CAN/ULC-S711.1:2019 | Standard for Bead-Applied Two Component Polyurethane Air Sealant Foam, Part 1: Material Specification | Table 5.9.1.1. ULC | CAN/ULC-S716.1:2019 | Standard for Exterior Insulation and Finish Systems (EIFS) – Materials and Systems | 5.9.4.1.(1) 9.27.14.1.(1) 9.27.14.2.(1) ULC | CAN/ULC-S716.2:2019 | Standard for Exterior Insulation and Finish Systems (EIFS) – Installation of EIFS Components and Water Resistive Barrier | 9.27.14.3.(2) ULC | CAN/ULC-S716.3:2019 | Standard for Exterior Insulation and Finish Systems (EIFS) – Design Application | 9.27.14.3.(1) ULC | CAN/ULC-S717.1:2017 | Standard for Flat Wall Insulating Concrete Form (ICF) Units – Material Properties | Table 5.9.1.1. 9.15.4.1.(1) ULC | CAN/ULC-S741-08 | Standard for Air Barrier Materials – Specification | 5.4.1.2.(2) ULC | CAN/ULC-S742:2020 | Standard for Air Barrier Assemblies – Specification | 5.4.1.2.(1) 5.4.1.2.(2) ULC | CAN/ULC-S1001-11 | Standard for Integrated Systems Testing of Fire Protection and Life Safety Systems | 3.2.9.1.(1) 9.10.1.2.(1) ULC | ULC/ORD-C199P-02 | Combustible Piping for Sprinkler Systems | 3.2.5.13.(2) 3.2.5.13.(5) ULC | ULC/ORD-C1254.6-95 | Fire Testing of Restaurant Cooking Area Fire Extinguishing System Units | 6.9.1.3.(1) USDA | October 1993 | Soil Survey Manual | 8.2.1.2.(2) WT | October 20, 2016 | Port Lands Flood Protection and Enabling Infrastructure Due Diligence Report | 1.3.3.6.(4) of Division C